Engineered for heavy-duty closed-circuit hydrostatic transmissions, the HENGYUHANG HYH90R / HYH90L Series axial piston variable displacement pumps deliver high power density, working pressures up to 450 bar continuous and 480 bar peak, and high overall operating efficiencies exceeding 93% with seamless 1:1 drop-in interchangeability for Danfoss Series 90 systems.
| Applications
Tailored for closed-loop mobile and industrial hydrostatic machinery, providing proportional fluid power for wheel traction, track drives, winch systems, and rotary work circuits across combine harvesters, skid steer loaders, directional drilling rigs, vibratory rollers, timber forwarders, and concrete transit mixers.
| Key Technical Specifications
Product Model: HYH90R / HYH90L Series (HYH90R042, HYH90L042, HYH90R055, HYH90L055, HYH90R075, HYH90L075, HYH90R100, HYH90L100, HYH90R130, HYH90L130, HYH90R180, HYH90L180, HYH90R250, HYH90L250)
Brand Replacement: Direct 1:1 drop-in replacement for Danfoss / Sauer-Danfoss Series 90 pumps (OEM or tailored as requested)
Displacement: 42.0 cm³/rev to 250.0 cm³/rev across 7 distinct frame sizes
Rotation Direction: Right-hand clockwise (HYH90R, CW) or Left-hand counterclockwise (HYH90L, CCW)
Speed Range: Rated operating speeds from 2,300 rpm up to 4,200 rpm; maximum intermittent speeds up to 4,600 rpm
Peak Pressure: Maximum working pressure of 450 bar [6,525 psi]; maximum peak operating pressure of 480 bar [6,960 psi]
| Overview of HENGYUHANG HYH90R / HYH90L Series Hydraulic Pumps
The HENGYUHANG HYH90R / HYH90L Series axial piston variable displacement pumps are premier heavy-duty, high-pressure hydraulic power units designed specifically for closed-circuit hydrostatic transmissions. Operating on the parallel axial piston and slipper design, fluid displacement is varied by adjusting the angle of a tilting cradle swashplate. Reversing the swashplate over center smoothly reverses the fluid flow direction through Ports A and B, delivering seamless forward, neutral, and reverse vehicle motion and motor rotation without external directional control valving.
Every HYH90R/L pump incorporates a built-in gerotor charge pump to replenish system leakage, circulate cooling flow, and supply clean servo control oil pressure. An array of SAE auxiliary rear mounting through-drive pads (SAE A, B, B-B, C, D, E) supports multi-pump tandem configurations for auxiliary open or closed circuits. Advanced control modules—including Manual Displacement Control (MDC), Electrical Displacement Control (EDC), Three-Position Electric Control (FNR), Hydraulic Displacement Control (HDC), and Non-Feedback Proportional Electric Control (NFPE)—provide responsive fluid modulation compatible with PLUS+1 and standard CAN-bus mobile controllers.
With high-strength spheroidal ductile iron housings, bimetallic valve plates, hardened cylinder blocks, dual multifunction high-pressure relief valves with pressure limiters (PL), and real-time Hall-effect digital pulse speed sensors, the HYH90R / HYH90L Series delivers proven reliability, high thermal stability, and exact 1:1 interchangeability with original Danfoss Series 90 pumps across demanding off-highway mobile and industrial machinery.
| Dimension of HENGYUHANG HYH90R / HYH90L Series Hydraulic Pumps
The physical mounting envelope, pilot diameters, shaft projections, and port locations of the HENGYUHANG HYH90R / HYH90L Series conform strictly to standard ISO 3019-1 and SAE J744 mounting interfaces.


| Installation Interface Specification
| Frame Size | Mounting Flange Standard (ISO 3019-1 / SAE) | Pilot Diameter (mm [in]) | Bolt Circle / Hole Pattern (mm [in]) | Mounting Holes |
|---|---|---|---|---|
| HYH90R042 / HYH90L042 | Flange 101-2 (SAE B 2-Bolt) | ∅101.60 +0.00/−0.05 [∅4.000] | 146.0 mm [5.750 in] bolt center | 2x ∅14.3 mm [∅0.562 in] |
| HYH90R055 / HYH90L055 | Flange 127-4 (SAE C 4-Bolt) | ∅127.00 +0.00/−0.05 [∅5.000] | 114.5×114.5 mm [4.508 in square] | 4x ∅14.27 mm [∅0.562 in] |
| HYH90R075 / HYH90L075 | Flange 127-4 (SAE C 4-Bolt) | ∅127.00 +0.00/−0.05 [∅5.000] | 114.5×114.5 mm [4.508 in square] | 4x ∅14.27 mm [∅0.562 in] |
| HYH90R100 / HYH90L100 | Flange 127-4 (SAE C 4-Bolt) | ∅127.00 +0.00/−0.05 [∅5.000] | 114.5×114.5 mm [4.508 in square] | 4x ∅14.27 mm [∅0.562 in] |
| HYH90R130 / HYH90L130 | Flange 152-4 (SAE D 4-Bolt) | ∅152.40 +0.00/−0.05 [∅6.000] | 161.6×161.6 mm [6.362 in square] | 4x ∅21.0 mm [∅0.827 in] |
| HYH90R180 / HYH90L180 | Flange 165-4 (SAE E 4-Bolt) | ∅165.10 +0.00/−0.05 [∅6.500] | 224.5 mm [8.839 in] square pattern | 4x ∅21.0 mm [∅0.827 in] |
| HYH90R250 / HYH90L250 | Flange 165-4 (SAE E 4-Bolt) | ∅165.10 +0.00/−0.05 [∅6.500] | 224.5 mm [8.839 in] square pattern | 4x ∅21.0 mm [∅0.827 in] |
| Frame Size | High-Pressure Main Ports A & B | Charge Pump Inlet Port S | Case Drain Ports L1, L2 |
|---|---|---|---|
| HYH90R042 / HYH90L042 | 3/4 in SAE J518 Code 62 (6,000 psi split flange, 3/8-16 UNC) | 1-1/16-12 UN-2B SAE O-ring boss | 7/8-14 UNF-2B SAE O-ring boss |
| HYH90R055 / HYH90L055 | 1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC) | 1-5/16-12 UN-2B SAE O-ring boss | 1-1/16-12 UN-2B SAE O-ring boss |
| HYH90R075 / HYH90L075 | 1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC) | 1-5/16-12 UN-2B SAE O-ring boss | 1-1/16-12 UN-2B SAE O-ring boss |
| HYH90R100 / HYH90L100 | 1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC) | 1-5/16-12 UN-2B SAE O-ring boss | 1-1/16-12 UN-2B SAE O-ring boss |
| HYH90R130 / HYH90L130 | 1-1/4 in SAE J518 Code 62 (6,000 psi split flange, 1/2-13 UNC) | 1-5/8-12 UN-2B SAE O-ring boss | 1-5/16-12 UN-2B SAE O-ring boss |
| HYH90R180 / HYH90L180 | 1-1/4 in SAE J518 Code 62 (6,000 psi split flange, 1/2-13 UNC) | 1-7/8-12 UN-2B SAE O-ring boss | 1-5/8-12 UN-2B SAE O-ring boss |
| HYH90R250 / HYH90L250 | 1-1/2 in SAE J518 Code 62 (6,000 psi split flange, 5/8-11 UNC) | 1-7/8-12 UN-2B SAE O-ring boss | 1-5/8-12 UN-2B SAE O-ring boss |
| Installation Specifications
| Mathematical Sizing & Performance Principles
Pump sizing calculations evaluate the machine drive requirements to provide sufficient flow at rated operating speeds. System variables are computed via the following fluid power sizing equations:
Output Flow Rate (Q): Q = (Vg · n · ηv) / 1000 [L/min] (Q = (Vg · n · ηv) / 231 [US gal/min])
Input Drive Torque (M): M = (Vg · Δp) / (20 · π · ηm) [N·m] (M = (Vg · Δp) / (2 · π · ηm) [lbf·in])
Input Drive Power (P): P = (Q · Δp) / (600 · ηt) = (M · n · π) / 30,000 [kW] (P = (Q · Δp) / (1714 · ηt) = (M · n · π) / 198,000 [hp])
Where:
Vg: Pump displacement per revolution (cm³/rev [in³/rev])
Δp: Differential system pressure between Port A and Port B (po − pi, bar [psi])
n: Pump input drive speed (rpm)
ηv: Volumetric efficiency (≥95% under nominal conditions)
ηm: Mechanical efficiency (≥92% across mid-to-high speed spectrum)
ηt: Total overall pump efficiency (ηt = ηv · ηm, up to 93%)
| Port Layout & System Circuit Identification
| Port Symbol | Nominal Size / Thread Type | Maximum Working Pressure | Functional Description & System Integration |
|---|---|---|---|
| Port A / Port B | 3/4 in to 1-1/2 in SAE J518 Code 62 split flange | 450 bar [6,525 psi] continuous / 480 bar [6,960 psi] peak | Main high-pressure system working ports. Opposite side (Option 60) or same side radial (Option 80). Port A is outlet for CW rotation / Port B is outlet for CCW rotation. |
| Port S | 1-1/16-12 to 1-7/8-12 UN-2B SAE O-ring boss | 4.0 bar [58 psi] max / 0.7 bar abs [9 in Hg vac] nominal | Internal gerotor charge pump suction inlet port. Plumbed directly to reservoir suction line. |
| Port L1 / L2 | 7/8-14 UNF to 1-5/8-12 UN-2B SAE O-ring boss | 3.0 bar [44 psi] continuous / 5.0 bar [73 psi] cold start | Case drain ports. Always connect the highest physical port location back to the reservoir to ensure complete housing fluid immersion. |
| Port M1 / M2 | 9/16-18 UNF-2B SAE J1926 straight thread O-ring boss | 480 bar [6,960 psi] | Diagnostic pressure gauge ports for system working pressure at Port A (M1) and Port B (M2). |
| Port M3 | 9/16-18 UNF-2B SAE J1926 straight thread O-ring boss | 40 bar [580 psi] | Diagnostic pressure gauge port for charge pump pressure monitoring. |
| Port M4 / M5 | 7/16-20 UNF-2B or 9/16-18 UNF-2B SAE J1926 boss | 40 bar [580 psi] | Servo control pressure diagnostic ports for servo cylinder A (M4) and servo cylinder B (M5). |
| Drive Shaft Matrix & Overhung Moment Limits
| Frame Size | Available Spline Options (ANSI B92.1) | Available Tapered Shaft Options | Max. Overhung Moment MR (Rated / Vibration) | Max. Overhung Moment MS (Shock Load) |
|---|---|---|---|---|
| 042 | C3 (15T, 16/32P) | T8 (∅25.40 mm [1.000 in], 1:8 Taper) | 860 N·m [7,600 lbf·in] | 3,020 N·m [26,700 lbf·in] |
| 055 | S1 (14T, 12/24P), C6 (21T, 16/32P) | T1 (∅34.925 mm [1.375 in], 1:8 Taper) | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] |
| 075 | S1 (14T, 12/24P), C6 (21T, 16/32P), C7 (23T, 16/32P), G1 (25T, 20/40P) | T1 (∅34.925 mm [1.375 in]), T6 (∅38.100 mm [1.500 in]) | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] |
| 100 | S1 (14T, 12/24P), C6 (21T, 16/32P), C7 (23T, 16/32P), F1 (13T, 8/16P), G1 (25T, 20/40P) | T6 (∅38.100 mm [1.500 in], 1:8 Taper) | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] |
| 130 | F1 (13T, 8/16P), C8 (27T, 16/32P) | T4 (∅44.450 mm [1.750 in], 1:8 Taper) | 3,160 N·m [28,000 lbf·in] | 10,730 N·m [95,000 lbf·in] |
| 180 | F1 (13T, 8/16P), C8 (27T, 16/32P) | Consult factory for keyed shaft options | 6,070 N·m [54,000 lbf·in] | 20,600 N·m [182,000 lbf·in] |
| 250 | F1 (13T, 8/16P), C8 (27T, 16/32P) | Consult factory for keyed shaft options | 6,070 N·m [54,000 lbf·in] | 20,600 N·m [182,000 lbf·in] |
| Technical Parameter | HYH90-042 | HYH90-055 | HYH90-075 | HYH90-100 | HYH90-130 | HYH90-180 | HYH90-250 |
|---|---|---|---|---|---|---|---|
| Max. Displacement (cm³/rev [in³/rev]) | 42.0 [2.56] | 55.0 [3.35] | 75.0 [4.59] | 100.0 [6.10] | 130.0 [7.93] | 180.0 [10.98] | 250.0 [15.26] |
| Minimum Operating Speed | 500 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm |
| Rated Speed (Continuous Full Load) | 4,200 rpm | 3,900 rpm | 3,600 rpm | 3,300 rpm | 3,100 rpm | 2,600 rpm | 2,300 rpm |
| Maximum Intermittent Speed | 4,600 rpm | 4,250 rpm | 3,950 rpm | 3,650 rpm | 3,400 rpm | 2,850 rpm | 2,500 rpm |
| Max. Continuous System Working Pressure | 450 bar [6,525 psi] | 450 bar [6,525 psi] | 450 bar [6,525 psi] | 450 bar [6,525 psi] | 450 bar [6,525 psi] | 450 bar [6,525 psi] | 450 bar [6,525 psi] |
| Maximum Peak System Pressure | 480 bar [6,960 psi] | 480 bar [6,960 psi] | 480 bar [6,960 psi] | 480 bar [6,960 psi] | 480 bar [6,960 psi] | 480 bar [6,960 psi] | 480 bar [6,960 psi] |
| Low-Pressure Loop (Min / Max) | 10 bar [145 psi] / 45 bar [650 psi] | 10 bar / 45 bar | 10 bar / 45 bar | 10 bar / 45 bar | 10 bar / 45 bar | 10 bar / 45 bar | 10 bar / 45 bar |
| Charge Relief Setting Range | 18 to 34 bar [261 to 493 psi] | 18 to 34 bar | 18 to 34 bar | 18 to 34 bar | 18 to 34 bar | 18 to 34 bar | 18 to 34 bar |
| Theoretical Flow at Rated Speed | 176 L/min [46 gpm] | 215 L/min [57 gpm] | 270 L/min [71 gpm] | 330 L/min [87 gpm] | 403 L/min [106 gpm] | 468 L/min [124 gpm] | 575 L/min [160 gpm] |
| Theoretical Torque at Max Disp. | 0.67 N·m/bar [410 lbf·in/1k psi] | 0.88 N·m/bar [530 lbf·in/1k psi] | 1.19 N·m/bar [730 lbf·in/1k psi] | 1.59 N·m/bar [970 lbf·in/1k psi] | 2.07 N·m/bar [1,260 lbf·in/1k psi] | 2.87 N·m/bar [1,750 lbf·in/1k psi] | 3.97 N·m/bar [2,433 lbf·in/1k psi] |
| Mass Moment of Inertia | 0.0023 kg·m² [0.0017 slug·ft²] | 0.0060 kg·m² [0.0044 slug·ft²] | 0.0096 kg·m² [0.0071 slug·ft²] | 0.0150 kg·m² [0.0111 slug·ft²] | 0.0230 kg·m² [0.0170 slug·ft²] | 0.0380 kg·m² [0.0280 slug·ft²] | 0.0650 kg·m² [0.0479 slug·ft²] |
| Weight (with MDC Control Option MA) | 34 kg [75 lb] | 40 kg [88 lb] | 49 kg [108 lb] | 68 kg [150 lb] | 88 kg [195 lb] | 136 kg [300 lb] | 154 kg [340 lb] |
| Threshold Group | Specification |
|---|---|
| Case Pressure Limits | Continuous allowable case pressure: 3.0 bar [44 psi]; maximum cold start peak pressure: 5.0 bar [73 psi]. |
| Shaft Seal External Pressure | Maximum allowable external pressure: 0.4 bar [5.8 psi]. |
| Operating Fluid Viscosity Limits | Minimum Intermittent Viscosity: 5.0 mm²/s [42 SUS] (t<1 min, not exceeding 2% duty cycle) Absolute Minimum Working Viscosity: 7.0 mm²/s [49 SUS] Recommended Continuous Working Viscosity Range: 12.0 to 80.0 mm²/s [66 to 370 SUS] Maximum Cold Start Viscosity: 1,600.0 mm²/s [7,500 SUS] |
| Temperature Limits | Minimum Cold Start Temperature: −40 ∘C [−40 ∘F] (t<3 min, p≤50 bar, n≤1,000 rpm) Recommended Working Temperature Range: 60 ∘C to 85 ∘C [140 ∘F to 185 ∘F] Continuous Rated Maximum Temperature: 104 ∘C [220 ∘F] (measured at housing drain port) Maximum Intermittent Peak Temperature: 115 ∘C [240 ∘F] |
| Fluid Cleanliness & Filtration Requirements | Standard Cleanliness: ISO 4406 Class 22/18/13 (SAE J1165) or cleaner under continuous operation. Suction Filtration: β₃₅₋₄₅ =75 (β₁₀ ≥2). Charge Pressure Filtration: β₁₅₋₂₀ =75 (β₁₀ ≥10). Recommended Suction Screen Mesh: 100 to 125 μm. |
Sustained continuous operating pressure of 450 bar [6,525 psi] and peak capability of 480 bar [6,960 psi] provide strong hydraulic tractive effort and rotary torque in a compact cast ductile iron housing.
Supports Manual Displacement Control (MDC), Electrical Displacement Control (EDC), 3-Position Electric (FNR), Hydraulic Displacement Control (HDC), and Non-Feedback Proportional Electric Control (NFPE), enabling drop-in compatibility with legacy mechanical linkages or modern CAN-bus electrohydraulic architectures.
Equipped with an internal gerotor charge pump (11 to 65 cc options) and rear auxiliary mounting pads (SAE A, B, B-B, C, D, E) with sealed covers, allowing direct tandem mounting of secondary closed or open-circuit gear and piston pumps without external splitters.
Dual multifunction valves integrate high-pressure relief and sequenced pressure limiter (PL) functionality. Upon reaching set thresholds (140 to 450 bar), the pressure limiter rapidly de-strokes the swashplate to mitigate heat buildup and protect hydrostatic drive components.
Accommodates suction filtration (Option S), remote pressure filtration (Option R), and integrated charge pressure filtration with short or long spin-on filter canisters (Options P and L), protecting critical internal rotating components.
Optional Hall-effect pulse speed sensors (Turck Eurofast or Packard Weather-Pack connectors) monitor swashplate angle and cylinder barrel rotation, delivering real-time speed and directional signals compatible with PLUS+1 microcontrollers and safety interlocks.
| 6. Cross Reference
Displacement & Frame Compatibility Matrix
| HENGYUHANG Model Code | Danfoss / Sauer-Danfoss Equivalent | Displacement (cm³/rev) | Mounting Flange Standard | Primary High-Pressure Ports | Standard Spline Configuration | Replacement Compatibility |
|---|---|---|---|---|---|---|
| HYH90R042 / HYH90L042 | 90R042 / 90L042 | 42.0 | SAE B 2-Bolt (Flange 101-2) | 3/4 in Code 62 Split Flange | 15T 16/32 Pitch (C3) | 100% 1:1 Direct Drop-In |
| HYH90R055 / HYH90L055 | 90R055 / 90L055 | 55.0 | SAE C 4-Bolt (Flange 127-4) | 1.00 in Code 62 Split Flange | 14T 12/24P (S1) or 21T 16/32P (C6) | 100% 1:1 Direct Drop-In |
| HYH90R075 / HYH90L075 | 90R075 / 90L075 | 75.0 | SAE C 4-Bolt (Flange 127-4) | 1.00 in Code 62 Split Flange | 14T 12/24P (S1), 21T (C6), 23T (C7) | 100% 1:1 Direct Drop-In |
| HYH90R100 / HYH90L100 | 90R100 / 90L100 | 100.0 | SAE C 4-Bolt (Flange 127-4) | 1.00 in Code 62 Split Flange | 14T (S1), 21T (C6), 23T (C7), 13T 8/16P (F1) | 100% 1:1 Direct Drop-In |
| HYH90R130 / HYH90L130 | 90R130 / 90L130 | 130.0 | SAE D 4-Bolt (Flange 152-4) | 1 1/4 in Code 62 Split Flange | 13T 8/16P (F1) or 27T 16/32P (C8) | 100% 1:1 Direct Drop-In |
| HYH90R180 / HYH90L180 | 90R180 / 90L180 | 180.0 | SAE E 4-Bolt (Flange 165-4) | 1 1/4 in Code 62 Split Flange | 13T 8/16P (F1) or 27T 16/32P (C8) | 100% 1:1 Direct Drop-In |
| HYH90R250 / HYH90L250 | 90R250 / 90L250 | 250.0 | SAE E 4-Bolt (Flange 165-4) | 1 1/2 in Code 62 Split Flange | 13T 8/16P (F1) or 27T 16/32P (C8) | 100% 1:1 Direct Drop-In |
Control Module Cross-Over Reference
| HENGYUHANG Control Code | OEM Control Designation | Functional Operating Specification | Electrical / Hydraulic Interface |
|---|---|---|---|
| MA / MB | Manual Displacement Control (MDC) | Manual control handle with internal feedback link; Option MB adds Neutral Start Switch (NSS) | Mechanical lever (±28° handle stroke, max 17 N⋅m [150 lbf⋅in]) |
| KA / KP / KN / KT | Electrical Displacement Control (EDC) | Proportional dual-coil electrohydraulic servo valve (14 to 85 mA); KN single-coil 4 to 20 mA | MS 4-pin (KA/KN), Packard Weather-Pack (KP), Deutsch DT04-2P (KT) |
| DC / DD | Three-Position Electric Control (FNR) | Solenoid on/off shifting between full forward, neutral, and full reverse | 12 VDC (340 mA, DC) or 24 VDC (170 mA, DD) with DIN 43650 connector |
| HF / HS | Hydraulic Displacement Control (HDC) | Pilot pressure proportional displacement shifting; HF: 3.0 to 11.0 bar; HS: 6.0 to 18.0 bar | Hydraulic pilot signal ports X1, X2 (7/16−20 UNF straight thread O-ring boss) |
| FA - FN | Non-Feedback Proportional Electric (NFPE) | Direct proportional pressure-reducing solenoid valve control without mechanical swashplate feedback | 12V or 24V proportional solenoids with AMP Junior Power Timer or Deutsch connectors |
| 7. Brand Replacement
The HENGYUHANG HYH90R / HYH90L Series axial piston variable pumps provide direct interchangeability with OEM hydraulic pumps across leading global fluid power manufacturers:
Danfoss / Sauer-Danfoss: Series 90 Variable Pumps (90R042, 90L042, 90R055, 90L055, 90R075, 90L075, 90R100, 90L100, 90R130, 90L130, 90R180, 90L180, 90R250, 90L250)
Bosch Rexroth: A4VG Series (A4VG28, A4VG40, A4VG56, A4VG71, A4VG90, A4VG125, A4VG180, A4VG250)
Parker Hannifin: Gold Cup Series (P6, P7, P11, P14) & Denison PV Series Hydrostatic Transmission Pumps
Eaton Vickers: Heavy Duty Series 1 / Series 2 Hydrostatic Pumps (Model 33 to Model 76)
Linde Hydraulics: HPV-02 Series Closed Circuit Axial Piston Pumps (HPV55, HPV75, HPV105, HPV135, HPV165, HPV210)
Bondioli & Pavesi: M4PV Series Heavy Duty Closed Loop Axial Piston Pumps
Moog: Radial & axial piston closed-loop variable transmission pumps
| 8. Applications
Agricultural Harvesters & Self-Propelled Equipment: Serves as primary hydrostatic ground propulsion and header drive pumps on combine harvesters, cotton pickers, sugarcane harvesters, and high-clearance self-propelled crop sprayers.
Construction Skid Steer & Track Loaders: Powers dual-path hydrostatic drive systems on wheeled skid steer loaders (SSL) and compact track loaders (CTL), delivering independent counter-rotation and responsive steering control.
Road Building & Compactor Machines: Drives traction travel and vibratory exciter mechanisms on heavy single-drum soil compactors, tandem asphalt rollers, road reclaimers, and asphalt paving machines.
Horizontal Directional Drilling (HDD) & Foundation Drilling: Powers continuous high-pressure rotary drill heads, carriage feed racks, and mud pump drives on directional trenchless drill rigs and rotary piling machines.
Forestry Harvesters, Forwarders & Skidders: Supplies hydrostatic drive power on multi-wheel timber forwarders, wheel skidders, tree feller bunchers, and stump shredders operating under continuous shock loads.
Transit Concrete Mixers & Specialized Mining Haulers: Mounted directly to engine PTO drives to power concrete mixing drum hydraulic drives, underground mining haulers, and tunneling transport equipment.
| 9. Packaging & Shipping
| Packaging Specification | Standard Configuration | Export Protection Detail |
|---|---|---|
| Port & Interface Sealing | Threaded polyethylene blanking plugs | Main ports A and B, charge inlet S, case drains L1, L2, and all gauge ports sealed against contamination |
| Surface Rust Prevention | Industrial corrosion-inhibitor oil spray + primer | Exterior machined pilot diameters, flange faces, and drive shaft splines coated with heavy-duty anti-rust grease |
| Inner Protective Barrier | Sealed VCI (Vapor Corrosion Inhibitor) plastic liner | Vacuum-sealed moisture-proof plastic enclosure with industrial desiccant bags |
| Cushioning & Positioning | Custom-molded high-density EPE foam cradles | Precision-contoured foam cushions supporting pump body, shaft extension, and control valve blocks |
| Outer Shipping Container | Heavy-duty heat-treated fumigation-free wooden case | Multi-ply plywood export crates compliant with ISPM 15 standards, secured with high-tensile steel strapping |
| Consignment Traceability | Dual-label identification system | Weatherproof exterior shipping markings; etched stainless steel serial nameplate riveted to pump housing |
| 10. Why Choose Hengyuhang?
Direct Factory Precision Manufacturing & CNC Excellence: Quanzhou Hengyuhang Power Technology Co., Ltd. operates an integrated manufacturing plant equipped with multi-axis CNC machining centers, horizontal boring mills, and precision spherical grinding machinery. Cylinder block bores and piston shoes are machined to micro-inch tolerances, maintaining barrel-to-port-plate flatnesses within 0.8 μm and surface roughness Ra < 0.2 μm for high volumetric sealing and long operational life.
100% Full-Cycle Multi-Parameter Factory Inspection: Every HYH90R / HYH90L pump undergoes comprehensive automated bench testing prior to shipment. Test procedures include full-speed validation up to rated rpm, continuous pressure holding at 450 bar, peak spike verification at 480 bar, volumetric efficiency certification (≥94%), charge pump relief valve cracking verification, servo control response profiling, and case drain leakage measurement logged into individual QA dossiers.
Seamless 1:1 OEM Drop-In Interchangeability: Manufactured strictly to Danfoss / Sauer-Danfoss Series 90 geometric and hydraulic standards, HYH90R/L pumps align with original pilot dimensions, bolt patterns, shaft splines, port centerlines, and control interfaces. Fleet managers and machinery manufacturers achieve direct field replacement without redesigning hydraulic piping or electrical wiring harnesses.
Flexible Engineering Customization & Rapid Prototyping: Supported by senior fluid power engineers, Hengyuhang provides custom shaft configurations, alternative displacement limiters, specialized charge pump displacements, customized relief valve pressures, and tailored control orifices. We provide low-MOQ prototype testing, custom OEM casting runs, and dedicated technical support for legacy equipment retrofits.
Robust Supply Chain, Extensive Inventory & Fast Global Dispatch: We maintain strategic inventories of raw casting bodies, finish-machined rotating groups, valve plates, control valves, and seal kits across all frame sizes (042 through 250). Standard configuration units ship within 48 to 72 hours, backed by worldwide express air freight and complete Door-to-Door (DDP) logistics services.
12-Month Comprehensive Warranty & Lifetime Technical Support: All HENGYUHANG HYH90R / HYH90L Series axial piston variable displacement pumps carry an unconditional 12-month factory warranty against manufacturing defects. Customers receive ongoing engineering support, hydraulic circuit consultations, CAD model verification, and comprehensive replacement parts availability.
HENGYUHANG Axial Piston Variable Displacement Pumps HYH90R / HYH90L Series are high-pressure, high-power-density hydraulic pumps engineered for advanced closed-circuit hydrostatic transmissions. Utilizing parallel axial pistons with precision-guided slippers and a cradle swashplate design, the pump provides stepless displacement adjustment from zero to maximum flow in both clockwise (HYH90R, CW) and counterclockwise (HYH90L, CCW) input rotations. Output flow direction reverses seamlessly across neutral, allowing smooth bi-directional motor speed and directional control. Available across seven primary displacement sizes—42 cm³, 55 cm³, 75 cm³, 100 cm³, 130 cm³, 180 cm³, and 250 cm³/rev—the series supports continuous working pressures up to 450 bar (6525 psi) and maximum peak pressures up to 480 bar (6960 psi). Featuring integrated gerotor charge pumps, multi-function valves with sequenced pressure limiters (PL) and high-pressure relief valves (HPRV), auxiliary SAE through-drive mounting pads, and PLUS+1 compatible control options, the HYH90R/L Series is custom-engineered to benchmark the mounting interfaces, performance envelopes, and control functions of Danfoss / Sauer-Danfoss Series 90 variable displacement pumps.
Technical Benchmark & Engineering Notice: All technical parameters, displacement ratings, rotational speeds, and dimensional interface standards presented on this page reference original manufacturer published technical documentation (Danfoss / Sauer-Danfoss Series 90 Technical Information Manual 11012416 Rev GC / April 2012, Pages 1–88, and Model Code Selection Guide 11012702 / July 2008, Pages 1–4). Replacement units are custom-manufactured; key mounting interfaces, centering pilots, shaft splines, port threads, and control pressure settings must be cross-verified against confirmed factory engineering drawings and test certificates prior to final commissioning.
Heavy-Duty Cradle Swashplate Architecture: Parallel axial piston rotating group with brass slippers and heavy-duty polymer swashplate bearings delivers high volumetric efficiency (≥95%) and mechanical efficiency under continuous cyclic loading.
Extensive Seven-Displacement Spectrum: Full coverage across seven frame sizes: 42 cm³ (2.56 in³), 55 cm³ (3.35 in³), 75 cm³ (4.59 in³), 100 cm³ (6.10 in³), 130 cm³ (7.93 in³), 180 cm³ (10.98 in³), and 250 cm³ (15.26 in³).
High Operating Pressure & Power Density: Rated continuous working pressure up to 450 bar (6525 psi) and peak intermittent pressure up to 480 bar (6960 psi), generating up to 354 kW (475 HP) on size 130 and 468 L/min flow on size 180.
Integrated Multi-Function Valve Assemblies: Incorporates dual high-pressure relief valves (HPRV), fast-acting sequenced pressure limiters (PL), charge check valves, and manual mechanical loop bypass valves in compact cartridge cavities.
Integrated Charge Pump & Filtration Options: Built-in gerotor charge pump provides system replenishment, cooling flow, and servo pressure. Filtration options include suction filtration, remote pressure filtration, and integral spin-on pressure filters.
Diverse Modular Control Configurations: Available with Manual Displacement Control (MDC), Electric Proportional Displacement Control (EDC), Forward-Neutral-Reverse 3-position electric control (FNR), Hydraulic Displacement Control (HDC), and Non-Feedback Proportional Electric Control (NFPE).
Auxiliary Through-Drive Capability: Standard rear cover auxiliary mounting pads (SAE-A, SAE-B, SAE-C, SAE-D, and SAE-E) allow direct tandem mounting of secondary closed-loop pumps, auxiliary open-loop gear pumps, or charge pumps.
Electronic Control & Sensor Compatibility: Fully compatible with PLUS+1 digital mobile machine controllers and non-contact magnetic hall-effect speed sensors (KPPG13408) with Packard Weather-Pack connectors.
The HENGYUHANG HYH90R/L Series variable displacement pump is engineered for demanding closed-circuit hydrostatic traction and heavy-duty auxiliary drives across heavy off-highway equipment:
Earthmoving & Road Construction: Primary propel and vibration drives on crawler bulldozers, asphalt pavers, soil compactors, tandem vibratory rollers, cold milling planers, and compact wheel loaders.
Agricultural & Harvesting Machinery: High-tractive hydrostatic drivetrains on combine harvesters, forage harvesters, self-propelled crop sprayers, sugar cane harvesters, and high-horsepower tractors.
Forestry & Material Handling: All-wheel drive traction on wheeled timber forwarders, log skidders, tree harvesters, rough-terrain reach stackers, and straddle carriers.
Mining, Drilling & Municipal Vehicles: Continuous propel drives on underground mining haulers, horizontal directional drilling rigs (HDD), concrete transit mixer drums, and airport runway snow clearing blowers.
| Technical Parameter / Frame Size | HYH90-042 | HYH90-055 | HYH90-075 | HYH90-100 | HYH90-130 | HYH90-180 | HYH90-250 |
|---|---|---|---|---|---|---|---|
| Maximum Displacement [cm³/rev] | 42.0 | 55.0 | 75.0 | 100.0 | 130.0 | 180.0 | 250.0 |
| Maximum Displacement [in³/rev] | 2.56 | 3.35 | 4.59 | 6.10 | 7.93 | 10.98 | 15.26 |
| Minimum Operating Input Speed [rpm] | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Rated Input Speed at Max Disp [rpm] | 4200 | 3900 | 3600 | 3300 | 3100 | 2600 | 2300 |
| Maximum Intermittent Input Speed [rpm] | 4600 | 4250 | 3950 | 3650 | 3400 | 2850 | 2500 |
| Maximum Working Pressure [bar / psi] | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 |
| Maximum Peak System Pressure [bar / psi] | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 |
| Theoretical Output Flow at Rated Speed [L/min] | 176 | 215 | 270 | 330 | 403 | 468 | 575 |
| Theoretical Output Flow at Rated Speed [US gpm] | 46 | 57 | 71 | 87 | 106 | 124 | 152 |
| Theoretical Input Torque at Vg max [Nm/bar] | 0.67 | 0.88 | 1.19 | 1.59 | 2.07 | 2.87 | 3.97 |
| Theoretical Input Torque at Vg max [lbf·in/1000 psi] | 410 | 530 | 730 | 970 | 1260 | 1750 | 2433 |
| Corner Power at Rated Speed & 450 bar [kW / HP] | 132 / 177 | 161 / 216 | 203 / 272 | 248 / 332 | 302 / 405 | 351 / 471 | 431 / 578 |
| Rotating Group Moment of Inertia J [kg·m²] | 0.0023 | 0.0060 | 0.0096 | 0.0150 | 0.0230 | 0.0380 | 0.0650 |
| Dry Weight (with Manual Control MDC) [kg / lbs] | 34 / 75 | 40 / 88 | 49 / 108 | 68 / 150 | 88 / 195 | 136 / 300 | 154 / 340 |
| Standard Charge Pump Displacement [cm³/rev] | 11 (0.67 in³) | 14 (0.85 in³) | 17 (1.04 in³) | 20 (1.22 in³) | 26 (1.58 in³) | 34 (2.07 in³) | 47 (2.87 in³) |
* All technical values referenced from Danfoss Series 90 Technical Information Manual 11012416 (Rev GC, Pages 8–9). Theoretical flow and torque values exclude mechanical and volumetric efficiency losses. Operational parameters for custom replacement units are verified through confirmed engineering approval drawings and factory dynamometer test certificates prior to dispatch.
Part 1: Primary mounting flange standards (ISO 3019-1 / SAE J744), centering pilot diameters, bolt patterns, ANSI B92.1 drive shafts, and rear auxiliary through-drive pads.
| Frame Size | Primary Mounting Flange | Centering Pilot Ø (ISO 3019-1) | Bolt Hole Pitch & Pattern | Standard Splined Drive Shaft | Auxiliary Rear Through-Drive Pads |
|---|---|---|---|---|---|
| HYH90-042 | SAE-B 2-bolt (Flange 102-2) | Ø101.6 mm [4.000 in] | 146.0 mm [5.75 in] pitch / 2x Ø14.3 mm | 14T 12/24 DP (S1) / 1.375 in Key (K1) | SAE-A (9T) / SAE-B (13T) |
| HYH90-055 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] | 114.5 mm [4.51 in] square / 4x Ø14.7 mm | 21T 16/32 DP (C6) / 14T 12/24 DP (S1) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
| HYH90-075 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] | 114.5 mm [4.51 in] square / 4x Ø14.7 mm | 21T 16/32 DP (C6) / 23T 16/32 DP (C7) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
| HYH90-100 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] | 114.5 mm [4.51 in] square / 4x Ø14.2 mm | 23T 16/32 DP (C7) / 13T 8/16 DP (F1) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
| HYH90-130 | SAE-D 4-bolt (Flange 152-4) | Ø152.4 mm [6.000 in] | 161.6 mm [6.36 in] square / 4x Ø20.6 mm | 27T 16/32 DP (C8) / 13T 8/16 DP (F1) | SAE-A, B, C, D (13T 8/16 DP) |
| HYH90-180 | SAE-D 4-bolt / SAE-E 4-bolt | Ø152.4 mm [6.000 in] / Ø165.1 mm | 161.6 mm / 224.5 mm / 4x Ø20.6 mm | 27T 16/32 DP (C8) / 13T 8/16 DP (F1) | SAE-A, B, C, D, E (13T / 27T) |
| HYH90-250 | SAE-E 4-bolt (Flange 165-4) | Ø165.1 mm [6.500 in] | 224.5 mm [8.84 in] square / 4x Ø20.6 mm | 27T 16/32 DP (C8) / 13T 8/16 DP (F1) | SAE-A, B, C, D, E (13T / 27T) |
Part 2: Main high-pressure working ports A & B (SAE J518 Code 62 4-bolt split flange), case drain connections, charge suction inlet, and system gauge ports.
| Frame Size | Main Working Ports A & B (SAE Code 62) | Port Layout Options | Case Drain Ports L1, L2 (SAE J514) | Charge Pump Suction Port S | Gauge Ports M1, M2, M3, M4, M5 |
|---|---|---|---|---|---|
| HYH90-042 | 3/4 in (DN19) Code 62 (3/8-16 UNC-2B) | Radial Twin Ports (Same side, 80) | 7/8-14 UNF-2B (SAE-10 O-Ring Boss) | 1 1/16-12 UN-2B (SAE-12) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-055 | 1.00 in (DN25) Code 62 (7/16-14 UNC-2B) | Same side (80) or Opposite side (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/16-12 UN-2B (SAE-16) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-075 | 1.00 in (DN25) Code 62 (7/16-14 UNC-2B) | Same side (80) or Opposite side (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/16-12 UN-2B (SAE-16) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-100 | 1.00 in (DN25) Code 62 (7/16-14 UNC-2B) | Same side (80) or Opposite side (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/8-12 UN-2B (SAE-20) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-130 | 1 1/4 in (DN32) Code 62 (1/2-13 UNC-2B) | Radial Twin Ports (Same side, 80) | 1 5/16-12 UN-2B (SAE-16 O-Ring Boss) | 1 5/16-12 UN-2B / 1 5/8-12 UN-2B | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-180 | 1 1/4 in (DN32) Code 62 (1/2-13 UNC-2B) | Radial Twin Ports (Same side, 80) | 1 5/8-12 UN-2B (SAE-20 O-Ring Boss) | 1 7/8-12 UN-2B (SAE-24) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYH90-250 | 1 1/2 in (DN38) Code 62 (5/8-11 UNC-2B) | Radial Twin Ports (Same side, 80) | 1 5/8-12 UN-2B (SAE-20 O-Ring Boss) | 1 7/8-12 UN-2B (SAE-24) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| Control Code | Designation & Actuation | Operational Principles & System Integration |
|---|---|---|
| MDC (MA / MB / ME / M8) | Manual Displacement Control (Mechanical Handle Actuation) | Direct mechanical handle control modulating internal pilot servo spool. Handle rotation directly controls swashplate angle and flow direction with spring-centered return. Option MB includes neutral start switch (NSS); Option ME/M8 integrates 12V/24V 2/2-way parking brake release solenoid. |
| EDC (KA / KP / KN) | Electric Displacement Control (Dual Proportional Solenoids) | Electro-hydraulic proportional control utilizing two proportional solenoids acting on pilot spool. Current input (12V/24V PWM or 4–20 mA current on KN) modulates servo cylinder pressure to provide stepless swashplate angle control. Electrical connector: MS circular (KA/KN) or Packard Weather-Pack (KP). |
| FNR (DC / DD) | 3-Position Electric Control (Forward-Neutral-Reverse) | Bi-stable on/off solenoid control shifting the pump swashplate between full forward displacement, spring-centered neutral, and full reverse displacement. Operating voltage: 12 VDC (DC) or 24 VDC (DD). |
| HDC (HF / HS) | Hydraulic Displacement Control (External Pilot Pressure) | Hydraulic remote pilot control actuating swashplate proportional to differential hydraulic pilot pressure applied across pilot ports X1 and X2. Standard pilot pressure control range: 3 to 11 bar [44 to 160 psi] (HF) or 6 to 18 bar [87 to 261 psi] (HS). |
| NFPE (FC / FD / FG / FH) | Non-Feedback Proportional Electric (Direct Proportional Pressure) | Proportional electro-hydraulic displacement control without internal mechanical feedback linkage. Dual proportional pressure-reducing valves (12V or 24V with AMP Junior-Timer connectors) directly meter pilot pressure to servo piston. Options FG/FH provide fast dynamic response. |
| Pos. | Code Segment | Available Options | Description & Engineering Specifications |
|---|---|---|---|
| 01 | Product Series | HYH90 | Series 90 closed-circuit axial piston variable displacement pump technology |
| 02 | Rotation Direction | R L | Clockwise rotation (CW, viewed from shaft end) Counterclockwise rotation (CCW, viewed from shaft end) |
| 03 | Frame Displacement | 042 / 055 075 / 100 130 / 180 / 250 | Displacement: 42.0 cm³ [2.56 in³] / 55.0 cm³ [3.35 in³] Displacement: 75.0 cm³ [4.59 in³] / 100.0 cm³ [6.10 in³] Displacement: 130.0 cm³ [7.93 in³] / 180.0 cm³ [10.98 in³] / 250.0 cm³ [15.26 in³] |
| 04 | Control Execution | MA / MB / ME KA / KP / KN DC / DD HF / HS FC / FD / FG / FH | Manual Displacement Control (MA: standard; MB: with NSS; ME: with 12V brake valve) Electric Displacement Control EDC (KA: MS connector; KP: Packard WP; KN: 4–20 mA) 3-position electric control FNR (DC: 12 VDC; DD: 24 VDC) Hydraulic displacement control HDC (HF: 3–11 bar; HS: 6–18 bar) Non-feedback proportional electric NFPE (FC: 12V; FD: 24V; FG/FH: fast response) |
| 05 | Pressure Regulation | 1 / 5 2 | Multi-function valve with Pressure Limiter (PL) and HPRV (Code 1 standard USA/China; Code 5 Europe) Multi-function valve with High Pressure Relief Valve only (without pressure limiter) |
| 06 | Auxiliary Mounting Pad | NN AB / AD BC / BG CD / DE / EF | No auxiliary through-drive pad (closed rear cover) SAE-A auxiliary mounting pad (9T 16/32 DP internal spline coupling sleeve) SAE-B auxiliary mounting pad (13T 16/32 DP internal spline coupling sleeve) SAE-C (14T 12/24 DP), SAE-D (13T 8/16 DP), or SAE-E (13T / 27T) through-drive |
| 07 | End Cap Ports Layout | 80 / 8 60 / 6 | Radial twin ports on same side (SAE J518 Code 62 split flange) Radial ports on opposite sides (SAE J518 Code 62 split flange, available on 055/075/100) |
| 08 | Filtration Execution | S R / T P / L D | Suction filtration system (standard) Remote pressure filtration circuit (without filter canister, R: 055–130; T: 180/250) Integrated pressure filtration with spin-on filter canister (P: short; L: long) Suction filtration for system without internal charge pump |
| 09 | Displacement Limiters | 3 / C 4 / M 7 | Without mechanical displacement limiters (standard; Code C for 180cc) With mechanical displacement limiters on both sides (factory set to 100% max displacement) NFPE standard execution, reinforced spring on one side of servo cylinder |
| 10 | Drive Shaft Configuration | C6 / C7 / C8 F1 / S1 K1 / K2 / K3 T1 / T2 / T4 | 21T 16/32 DP (C6), 23T 16/32 DP (C7), 27T 16/32 DP (C8) ANSI B92.1 splines 13T 8/16 DP (F1 on 100–250), 14T 12/24 DP (S1 on 042–100) Straight cylindrical keyed shafts: 1.375 in (K1), 1.500 in (K2), 1.750 in (K3) Tapered keyed shafts: 1.375 in (T1), 1.500 in (T2), 1.750 in (T4) |
| 11 | Charge Pump Size | B / C / D E / F / H / J / K L / N | 11 cm³ [B], 14 cm³ [C], 17 cm³ [D] internal gerotor charge pump 20 cm³ [E], 26 cm³ [F], 34 cm³ [H], 47 cm³ [J], 65 cm³ [K] charge pump External charge pump with internal relief valve (L) or without auxiliary flange (N) |
| 12 | Control Orifice Setting | 00 / 01 / 02 03 04 / 05 / 06 / 09 G4 / G8 / GB | Without orifice (00), Ø0.46 mm (01), Ø0.66 mm (02) Ø0.81 mm (03, standard orifice setting for MDC, EDC, HDC) Damped / high-flow orifices: Ø1.02 mm (04), Ø1.37 mm (05), Ø1.57 mm (06), Ø2.34 mm (09) Calibrated orifices for FNR controls: Ø0.46 mm (G4), Ø0.66 mm (G8), Ø0.81 mm (GB) |
| 13 | Special Hardware Feature | NNN GBA / GCA EBA / EBC FAC / FAD | Standard hardware execution Valve plate with CP 15 +0.5° (GBA) or CP 15 +1.5° (GCA) Hall-effect electronic speed sensor KPPG13408 (EBA: sensor; EBC: with Weather-Pack) Valve plate with reinforced servo centering springs (FAC / FAD) |
| 14 | High Pressure Relief (Y/Z) | 26 / 29 / 32 35 / 38 / 40 / 42 | HPRV pressure setting for Port A (Y) and Port B (Z): 260 bar [26], 290 bar [29], 320 bar [32] HPRV pressure setting: 350 bar [35], 380 bar [38], 400 bar [40], 420 bar [42] |
| 15 | Charge Pressure Relief (K) | 18 / 20 / 22 24 26 / 28 / 30 / 34 | Charge relief valve nominal setting: 18 bar [18], 20 bar [20], 22 bar [22] 24 bar [Code 24 = 350 psi, factory standard setting] Charge relief valve setting: 26 bar [26], 28 bar [28], 30 bar [30], 34 bar [34] |
Example Standard Order Codes: HYH90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 (55 cm³, CW, 12V EDC Control, Pressure Limiter, Same-side Ports, Suction Filtration, 21T Spline, 14 cm³ Charge Pump, Ø0.81 mm Orifice, 350 bar HPRV, 24 bar Charge Relief) or HYH90L100-MA-1-AB-80-S-3-F1-E-03-NNN-42-42-24 (100 cm³, CCW, Manual MDC Control, SAE-A Auxiliary Pad, 13T 8/16 DP Spline, 20 cm³ Charge Pump, 420 bar HPRV, 24 bar Charge Relief).
HENGYUHANG HYH90R / HYH90L Series variable displacement pumps are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss 90R / 90L Series mounting pilots, shaft splines, port locations, and control characteristics. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:
| OEM Danfoss Model Code | HENGYUHANG Benchmarked Model | Displacement & Flange | Input Shaft & Port Style | Control & Valve Setting | Compatibility Status |
|---|---|---|---|---|---|
| 90R042-MA-1-NN-80-S-3-S1-B-03-NNN-35-35-24 | HYH90R042-MA-1-NN-80-S-3-S1-B-03-NNN-35-35-24 | 42 cm³, SAE-B 2-bolt | 14T 12/24 DP, Radial 3/4" | Manual MDC, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| 90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 | HYH90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 | 55 cm³, SAE-C 4-bolt | 21T 16/32 DP, Radial 1.00" | 12V EDC Control, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| 90L075-KA-1-NN-80-S-3-C6-D-03-NNN-38-38-24 | HYH90L075-KA-1-NN-80-S-3-C6-D-03-NNN-38-38-24 | 75 cm³, SAE-C 4-bolt | 21T 16/32 DP, Radial 1.00" | 12V EDC Control, PL 380 bar | Benchmarked Equivalent (Verify Fit) |
| 90R075-MA-1-AB-80-S-3-C7-D-03-NNN-42-42-24 | HYH90R075-MA-1-AB-80-S-3-C7-D-03-NNN-42-42-24 | 75 cm³, SAE-C 4-bolt | 23T 16/32 DP, SAE-A Rear | Manual MDC, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90L100-KA-1-BC-80-S-3-F1-E-03-NNN-42-42-24 | HYH90L100-KA-1-BC-80-S-3-F1-E-03-NNN-42-42-24 | 100 cm³, SAE-C 4-bolt | 13T 8/16 DP, SAE-B Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R130-KA-1-CD-80-S-3-C8-F-03-NNN-42-42-24 | HYH90R130-KA-1-CD-80-S-3-C8-F-03-NNN-42-42-24 | 130 cm³, SAE-D 4-bolt | 27T 16/32 DP, SAE-C Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R180-KA-1-DE-80-S-C-C8-H-03-NNN-42-42-24 | HYH90R180-KA-1-DE-80-S-C-C8-H-03-NNN-42-42-24 | 180 cm³, SAE-D/E 4-bolt | 27T 16/32 DP, SAE-D Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R250-KA-1-EF-80-S-3-C8-J-03-NNN-42-42-24 | HYH90R250-KA-1-EF-80-S-3-C8-J-03-NNN-42-42-24 | 250 cm³, SAE-E 4-bolt | 27T 16/32 DP, SAE-E Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
1. Initial Casing Pre-filling & Deaeration: Prior to initial startup, the pump housing must be completely pre-filled with clean, filtered hydraulic oil through the highest positioned case drain port (L1 or L2) and thoroughly deaerated. Operating the unit without oil in the casing will cause immediate boundary friction seizure to the brass piston slippers, cylinder block barrel, and swashplate bearings.
2. Charge Pump Suction Pressure & Vacuum Limits: Suction line S must be sized to ensure absolute charge pump suction pressure remains ≥ 0.7 bar abs [9 in Hg vacuum] at normal operating temperature. Minimum allowable suction pressure during cold start is 0.2 bar abs [24 in Hg vacuum]. Never exceed 4.0 bar [58 psi] suction pressure.
3. Housing Drain Routing & Casing Pressure Limits: Case drain lines must be piped directly back to the reservoir below the minimum fluid level without flow restrictions. Rated continuous casing pressure must not exceed 3.0 bar [44 psi] (cold start maximum ≤ 5.0 bar [73 psi]). External shaft seal differential pressure must not exceed 0.4 bar [5.8 psi].
4. Fluid Cleanliness Standard: Maintain fluid cleanliness strictly according to ISO 4406 at 22/18/13 or cleaner. For charge pressure filtration, utilize filter elements with β15-20 = 75 (β10 ≥ 10). Contaminated fluid will accelerate servo spool sticking and barrel face scoring.
5. Viscosity & Operating Temperature Range: Optimal operating viscosity is νopt = 12 to 80 mm²/s [66 to 370 SUS] (minimum allowable 7 mm²/s [49 SUS]; cold-start maximum 1600 mm²/s [7500 SUS]). Continuous oil temperature should remain within 60 to 85 °C [140 to 185 °F] (rated maximum 104 °C [220 °F]; intermittent peak ≤ 115 °C [240 °F]).
Reference Benchmark Datasheets: Danfoss / Sauer-Danfoss Series 90 Axial Piston Pumps Technical Information Manual (Document Ref: 11012416, Revision GC, April 2012 Edition, Pages 1–88) and Series 90 Model Code Selection Guide (Document Ref: 11012702, July 2008 Edition, Pages 1–4).
Quality Inspection & Performance Testing: Every HENGYUHANG HYH90R / HYH90L pump is dynamically validated on automated hydraulic test benches for full-displacement volumetric flow, input torque, servo control hysteresis, and high-pressure relief valve cracking under 450 bar working pressure prior to dispatch.
Custom Engineering & Tailored Configurations: HENGYUHANG provides custom drive shaft spline lengths, customized multi-function valve pressure relief settings (140 to 420 bar), special charge pump displacements, tailored control orifice diameters, and PLUS+1 compatible electrical connector pinouts. Critical mounting dimensions, pilot tolerances, and hydraulic circuit parameters should be cross-verified against OEM reference drawings for specific machine serial numbers.
| Technical Parameter / Frame Size | HYH90-042 | HYH90-055 | HYH90-075 | HYH90-100 | HYH90-130 | HYH90-180 | HYH90-250 |
|---|---|---|---|---|---|---|---|
| Maximum Displacement [cm³/rev] | 42.0 | 55.0 | 75.0 | 100.0 | 130.0 | 180.0 | 250.0 |
| Maximum Displacement [in³/rev] | 2.56 | 3.35 | 4.59 | 6.10 | 7.93 | 10.98 | 15.26 |
| Minimum Operating Input Speed [rpm] | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Rated Input Speed at Max Disp [rpm] | 4200 | 3900 | 3600 | 3300 | 3100 | 2600 | 2300 |
| Maximum Intermittent Input Speed [rpm] | 4600 | 4250 | 3950 | 3650 | 3400 | 2850 | 2500 |
| Maximum Working Pressure [bar / psi] | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 | 450 / 6525 |
| Maximum Peak System Pressure [bar / psi] | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 | 480 / 6960 |
| Theoretical Output Flow at Rated Speed [L/min] | 176 | 215 | 270 | 330 | 403 | 468 | 575 |
| Theoretical Output Flow at Rated Speed [US gpm] | 46 | 57 | 71 | 87 | 106 | 124 | 152 |
| Theoretical Input Torque at Vg max [Nm/bar] | 0.67 | 0.88 | 1.19 | 1.59 | 2.07 | 2.87 | 3.97 |
| Theoretical Input Torque at Vg max [lbf·in/1000 psi] | 410 | 530 | 730 | 970 | 1260 | 1750 | 2433 |
| Corner Power at Rated Speed & 450 bar [kW / HP] | 132 / 177 | 161 / 216 | 203 / 272 | 248 / 332 | 302 / 405 | 351 / 471 | 431 / 578 |
| Rotating Group Moment of Inertia J [kg·m²] | 0.0023 | 0.0060 | 0.0096 | 0.0150 | 0.0230 | 0.0380 | 0.0650 |
| Dry Weight (with Manual Control MDC) [kg / lbs] | 34 / 75 | 40 / 88 | 49 / 108 | 68 / 150 | 88 / 195 | 136 / 300 | 154 / 340 |
| Standard Charge Pump Displacement [cm³/rev] | 11 (0.67 in³) | 14 (0.85 in³) | 17 (1.04 in³) | 20 (1.22 in³) | 26 (1.58 in³) | 34 (2.07 in³) | 47 (2.87 in³) |
* All technical values referenced from Danfoss Series 90 Technical Information Manual 11012416 (Rev GC, Pages 8–9). Theoretical flow and torque values exclude mechanical and volumetric efficiency losses. Operational parameters for custom replacement units are verified through confirmed engineering approval drawings and factory dynamometer test certificates prior to dispatch.
| Pos. | Code Segment | Available Options | Description & Engineering Specifications |
|---|---|---|---|
| 01 | Product Series | HYH90 | Series 90 closed-circuit axial piston variable displacement pump technology |
| 02 | Rotation Direction | R L | Clockwise rotation (CW, viewed from shaft end) Counterclockwise rotation (CCW, viewed from shaft end) |
| 03 | Frame Displacement | 042 / 055 075 / 100 130 / 180 / 250 | Displacement: 42.0 cm³ [2.56 in³] / 55.0 cm³ [3.35 in³] Displacement: 75.0 cm³ [4.59 in³] / 100.0 cm³ [6.10 in³] Displacement: 130.0 cm³ [7.93 in³] / 180.0 cm³ [10.98 in³] / 250.0 cm³ [15.26 in³] |
| 04 | Control Execution | MA / MB / ME KA / KP / KN DC / DD HF / HS FC / FD / FG / FH | Manual Displacement Control (MA: standard; MB: with NSS; ME: with 12V brake valve) Electric Displacement Control EDC (KA: MS connector; KP: Packard WP; KN: 4–20 mA) 3-position electric control FNR (DC: 12 VDC; DD: 24 VDC) Hydraulic displacement control HDC (HF: 3–11 bar; HS: 6–18 bar) Non-feedback proportional electric NFPE (FC: 12V; FD: 24V; FG/FH: fast response) |
| 05 | Pressure Regulation | 1 / 5 2 | Multi-function valve with Pressure Limiter (PL) and HPRV (Code 1 standard USA/China; Code 5 Europe) Multi-function valve with High Pressure Relief Valve only (without pressure limiter) |
| 06 | Auxiliary Mounting Pad | NN AB / AD BC / BG CD / DE / EF | No auxiliary through-drive pad (closed rear cover) SAE-A auxiliary mounting pad (9T 16/32 DP internal spline coupling sleeve) SAE-B auxiliary mounting pad (13T 16/32 DP internal spline coupling sleeve) SAE-C (14T 12/24 DP), SAE-D (13T 8/16 DP), or SAE-E (13T / 27T) through-drive |
| 07 | End Cap Ports Layout | 80 / 8 60 / 6 | Radial twin ports on same side (SAE J518 Code 62 split flange) Radial ports on opposite sides (SAE J518 Code 62 split flange, available on 055/075/100) |
| 08 | Filtration Execution | S R / T P / L D | Suction filtration system (standard) Remote pressure filtration circuit (without filter canister, R: 055–130; T: 180/250) Integrated pressure filtration with spin-on filter canister (P: short; L: long) Suction filtration for system without internal charge pump |
| 09 | Displacement Limiters | 3 / C 4 / M 7 | Without mechanical displacement limiters (standard; Code C for 180cc) With mechanical displacement limiters on both sides (factory set to 100% max displacement) NFPE standard execution, reinforced spring on one side of servo cylinder |
| 10 | Drive Shaft Configuration | C6 / C7 / C8 F1 / S1 K1 / K2 / K3 T1 / T2 / T4 | 21T 16/32 DP (C6), 23T 16/32 DP (C7), 27T 16/32 DP (C8) ANSI B92.1 splines 13T 8/16 DP (F1 on 100–250), 14T 12/24 DP (S1 on 042–100) Straight cylindrical keyed shafts: 1.375 in (K1), 1.500 in (K2), 1.750 in (K3) Tapered keyed shafts: 1.375 in (T1), 1.500 in (T2), 1.750 in (T4) |
| 11 | Charge Pump Size | B / C / D E / F / H / J / K L / N | 11 cm³ [B], 14 cm³ [C], 17 cm³ [D] internal gerotor charge pump 20 cm³ [E], 26 cm³ [F], 34 cm³ [H], 47 cm³ [J], 65 cm³ [K] charge pump External charge pump with internal relief valve (L) or without auxiliary flange (N) |
| 12 | Control Orifice Setting | 00 / 01 / 02 03 04 / 05 / 06 / 09 G4 / G8 / GB | Without orifice (00), Ø0.46 mm (01), Ø0.66 mm (02) Ø0.81 mm (03, standard orifice setting for MDC, EDC, HDC) Damped / high-flow orifices: Ø1.02 mm (04), Ø1.37 mm (05), Ø1.57 mm (06), Ø2.34 mm (09) Calibrated orifices for FNR controls: Ø0.46 mm (G4), Ø0.66 mm (G8), Ø0.81 mm (GB) |
| 13 | Special Hardware Feature | NNN GBA / GCA EBA / EBC FAC / FAD | Standard hardware execution Valve plate with CP 15 +0.5° (GBA) or CP 15 +1.5° (GCA) Hall-effect electronic speed sensor KPPG13408 (EBA: sensor; EBC: with Weather-Pack) Valve plate with reinforced servo centering springs (FAC / FAD) |
| 14 | High Pressure Relief (Y/Z) | 26 / 29 / 32 35 / 38 / 40 / 42 | HPRV pressure setting for Port A (Y) and Port B (Z): 260 bar [26], 290 bar [29], 320 bar [32] HPRV pressure setting: 350 bar [35], 380 bar [38], 400 bar [40], 420 bar [42] |
| 15 | Charge Pressure Relief (K) | 18 / 20 / 22 24 26 / 28 / 30 / 34 | Charge relief valve nominal setting: 18 bar [18], 20 bar [20], 22 bar [22] 24 bar [Code 24 = 350 psi, factory standard setting] Charge relief valve setting: 26 bar [26], 28 bar [28], 30 bar [30], 34 bar [34] |
Example Standard Order Codes: HYH90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 (55 cm³, CW, 12V EDC Control, Pressure Limiter, Same-side Ports, Suction Filtration, 21T Spline, 14 cm³ Charge Pump, Ø0.81 mm Orifice, 350 bar HPRV, 24 bar Charge Relief) or HYH90L100-MA-1-AB-80-S-3-F1-E-03-NNN-42-42-24 (100 cm³, CCW, Manual MDC Control, SAE-A Auxiliary Pad, 13T 8/16 DP Spline, 20 cm³ Charge Pump, 420 bar HPRV, 24 bar Charge Relief).
HENGYUHANG HYH90R / HYH90L Series variable displacement pumps are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss 90R / 90L Series mounting pilots, shaft splines, port locations, and control characteristics. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:
| OEM Danfoss Model Code | HENGYUHANG Benchmarked Model | Displacement & Flange | Input Shaft & Port Style | Control & Valve Setting | Compatibility Status |
|---|---|---|---|---|---|
| 90R042-MA-1-NN-80-S-3-S1-B-03-NNN-35-35-24 | HYH90R042-MA-1-NN-80-S-3-S1-B-03-NNN-35-35-24 | 42 cm³, SAE-B 2-bolt | 14T 12/24 DP, Radial 3/4" | Manual MDC, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| 90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 | HYH90R055-KA-1-NN-80-S-3-C6-C-03-NNN-35-35-24 | 55 cm³, SAE-C 4-bolt | 21T 16/32 DP, Radial 1.00" | 12V EDC Control, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| 90L075-KA-1-NN-80-S-3-C6-D-03-NNN-38-38-24 | HYH90L075-KA-1-NN-80-S-3-C6-D-03-NNN-38-38-24 | 75 cm³, SAE-C 4-bolt | 21T 16/32 DP, Radial 1.00" | 12V EDC Control, PL 380 bar | Benchmarked Equivalent (Verify Fit) |
| 90R075-MA-1-AB-80-S-3-C7-D-03-NNN-42-42-24 | HYH90R075-MA-1-AB-80-S-3-C7-D-03-NNN-42-42-24 | 75 cm³, SAE-C 4-bolt | 23T 16/32 DP, SAE-A Rear | Manual MDC, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90L100-KA-1-BC-80-S-3-F1-E-03-NNN-42-42-24 | HYH90L100-KA-1-BC-80-S-3-F1-E-03-NNN-42-42-24 | 100 cm³, SAE-C 4-bolt | 13T 8/16 DP, SAE-B Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R130-KA-1-CD-80-S-3-C8-F-03-NNN-42-42-24 | HYH90R130-KA-1-CD-80-S-3-C8-F-03-NNN-42-42-24 | 130 cm³, SAE-D 4-bolt | 27T 16/32 DP, SAE-C Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R180-KA-1-DE-80-S-C-C8-H-03-NNN-42-42-24 | HYH90R180-KA-1-DE-80-S-C-C8-H-03-NNN-42-42-24 | 180 cm³, SAE-D/E 4-bolt | 27T 16/32 DP, SAE-D Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
| 90R250-KA-1-EF-80-S-3-C8-J-03-NNN-42-42-24 | HYH90R250-KA-1-EF-80-S-3-C8-J-03-NNN-42-42-24 | 250 cm³, SAE-E 4-bolt | 27T 16/32 DP, SAE-E Rear | 12V EDC Control, PL 420 bar | Benchmarked Equivalent (Verify Fit) |
No. 173, Xiacuo, Sihuang Village, Xiamei Town, Nan 'an City, Fujian Province