HENGYUHANG Axial Piston Motors HYH90M

Engineered for closed-circuit hydrostatic transmissions under extreme operating conditions, the HENGYUHANG HYH90M Series axial piston motors deliver proven high-power density, continuous working pressures up to 420 bar, and superior overall operating efficiencies exceeding 93% with seamless 1:1 drop-in interchangeability for Danfoss Series 90 fixed and variable drive systems.

| Applications

Tailored for heavy-duty closed-loop mobile and industrial hydrostatic machinery, providing robust propulsion and auxiliary work drive power across combine harvesters, crawler excavators, directional drill rigs, asphalt compactors, forestry forwarders, and high-pressure winches.

| Key Technical Specifications

Product Model: HYH90M Series (Fixed Displacement: HYH90M042, HYH90M055, HYH90M075, HYH90M100, HYH90M130; Cartridge Fixed: HYH90K055, HYH90K075; Variable Displacement: HYH90V055, HYH90M055-V)

Brand Replacement: Direct 1:1 drop-in replacement for Danfoss / Sauer-Danfoss Series 90 motors (OEM or tailored as requested)

Displacement: 42.0 cm³/rev to 130.0 cm³/rev across 5 fixed displacement frame sizes and 1 two-position variable frame size

Rotation Direction: Bi-directional rotation (clockwise CW and counterclockwise CCW via reversible port flow)

Speed Range: Rated continuous speeds up to 4,200 rpm at maximum displacement; maximum intermittent speed up to 5,100 rpm at minimum displacement

Peak Pressure: Rated continuous system pressure of 420 bar [6,000 psi]; maximum peak operating pressure of 480 bar [7,000 psi]

| Overview of HENGYUHANG HYH90M Series Hydraulic Motors

The HENGYUHANG HYH90M Series axial piston hydraulic motors are premier heavy-duty, high-power-density drive units engineered specifically for high-stress closed-circuit hydrostatic drive lines. Built on the proven parallel axial piston and slipper architecture operating against fixed or variable-angle swashplates, the HYH90M Series provides precise fluid-to-mechanical energy conversion with minimal flow shear, exceptional starting torque efficiency, and proven thermal stability.

Every HYH90M motor incorporates high-strength spheroidal ductile iron housings, hardened bi-metal valve plates, high-grade alloy cylinder barrels, and precision-ground spherical slipper retainers. Available in five fixed displacement frame sizes (HYH90M042, HYH90M055, HYH90M075, HYH90M100, and HYH90M130) and one versatile two-position variable displacement frame size (HYH90V055 / HYH90M055-V), the series accommodates both standard SAE 2-bolt and 4-bolt flange mountings as well as integrated planetary winch/wheel-drive cartridge configurations (HYH90K055, HYH90K075).

For closed-loop circuits demanding active fluid thermal conditioning and particle extraction, HYH90M motors feature an integrated, factory-tuned low-pressure loop flushing shuttle valve with orificed charge pressure relief valves (cracking pressure 16 bar [232 psi]). Dual-rotation capability, multi-position SAE J518 Code 62 6,000 psi high-pressure flange ports (axial rear or twin radial), and real-time Hall-effect digital speed sensors allow complete plug-and-play field replacement of original Sauer-Danfoss Series 90 installations without hydraulic or mechanical re-engineering.

| Dimension of HENGYUHANG HYH90M Series Hydraulic Motors

The physical envelope and installation geometry of the HENGYUHANG HYH90M Series conform 1:1 to standard SAE J744 mounting interfaces and direct OEM planetary gearbox cartridge counterbores.

| Installation Interface Specification

Frame Size & Mounting StylePilot Diameter (mm [in])Bolt Circle Diameter / Pattern (mm [in])Mounting Hole Configuration
HYH90M042 (SAE B Mount)∅101.60 +0.00/−0.05 [∅4.000]146.0 mm [5.750 in] 2-bolt2x ∅14.3 mm [∅0.563 in] clearance holes
HYH90M055 (SAE C Mount)∅127.00 +0.00/−0.05 [∅5.000]114.5×114.5 mm [4.508 in square], 4-bolt4x ∅14.7 mm [∅0.580 in] clearance holes
HYH90K055 (Cartridge Mount)∅159.975±0.025 [∅6.2982]∅230.0 mm [∅9.055 in], 2-ear pilot2x ∅17.1 mm [∅0.673 in] slotted holes
HYH90V055 (SAE C Variable)∅127.00 +0.00/−0.05 [∅5.000]114.5×114.5 mm [4.508 in square], 4-bolt4x ∅14.2 mm [∅0.560 in] clearance holes
HYH90M075 (SAE C Mount)∅127.00 +0.00/−0.05 [∅5.000]114.5×114.5 mm [4.508 in square], 4-bolt4x ∅14.7 mm [∅0.580 in] clearance holes
HYH90K075 (Cartridge Mount)∅189.975±0.025 [∅7.4793]∅265.0 mm [∅10.433 in], 2-ear pilot2x ∅22.2 mm [∅0.874 in] slotted holes
HYH90M100 (SAE C Mount)∅127.00 +0.00/−0.05 [∅5.000]114.5×114.5 mm [4.508 in square], 4-bolt4x ∅14.2 mm [∅0.560 in] clearance holes
HYH90M130 (SAE D Mount)∅152.40 +0.00/−0.05 [∅6.000]161.6×161.6 mm [6.362 in square], 4-bolt4x ∅17.4 mm [∅0.685 in] clearance holes
Frame Size & Mounting StyleHigh-Pressure Main Ports A & BCase Drain Ports L1, L2Gauge Diagnostic Ports M1, M2, M3
HYH90M042 (SAE B Mount)3/4 in SAE J518 Code 62 (6,000 psi split flange, 3/8-16 UNC)7/8-14 UNF-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2) SAE J1926 O-ring boss
HYH90M055 (SAE C Mount)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)7/8-14 UNF-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926
HYH90K055 (Cartridge Mount)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)7/8-14 UNF-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926
HYH90V055 (SAE C Variable)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)7/8-14 UNF-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) + 7/16-20 UNF (X1)
HYH90M075 (SAE C Mount)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)1-1/16-12 UN-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926
HYH90K075 (Cartridge Mount)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)1-1/16-12 UN-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926
HYH90M100 (SAE C Mount)1.00 in SAE J518 Code 62 (6,000 psi split flange, 7/16-14 UNC)1-1/16-12 UN-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926
HYH90M130 (SAE D Mount)1-1/4 in SAE J518 Code 62 (6,000 psi split flange, 1/2-13 UNC)1-5/16-12 UN-2B SAE J1926 O-ring boss9/16-18 UNF-2B (M1, M2, M3) SAE J1926

| Installation Specifications

| Mathematical Sizing & Performance Principles

Hydrostatic drive line sizing is determined by load torque requirements and available pump flow rate. Motor performance variables are calculated via the following fluid power equations:

Input Flow Rate (Q): Q = (Vg · n) / (1000 · ηv)  [L/min]  (Q = (Vg · n) / (231 · ηv)  [US gal/min])

Output Torque (M): M = (Vg · Δp · ηm) / (20 · π)  [N·m]  (M = (Vg · Δp · ηm) / (2 · π)  [lbf·in])

Output Shaft Power (P): P = (Q · Δp · ηt) / 600  [kW]  (P = (Q · Δp · ηt) / 1714  [hp])

Motor Speed (n): n = (Q · 1000 · ηv) / Vg  [min⁻¹ (rpm)]  (n = (Q · 231 · ηv) / Vg  [min⁻¹ (rpm)])

Where:

Vg: Displacement per revolution (cm³/rev [in³/rev])

Δp: Differential system pressure between Port A and Port B (po − pi, bar [psi])

n: Motor output shaft speed (rpm)

ηv: Volumetric efficiency (≥95% at rated continuous speed and pressure)

ηm: Mechanical-hydraulic efficiency (≥92% across mid-to-high speed spectrum)

ηt: Total overall motor efficiency (ηt = ηv · ηm, up to 93%)

| Port Function & Circuit Identification Matrix

Port SymbolNominal Size / Thread TypeMaximum Working PressureFunctional Description & System Integration
Port A / Port B3/4 in, 1.00 in, or 1-1/4 in SAE J518 Code 62 split flange420 bar [6,000 psi] continuous / 480 bar [7,000 psi] peakMain bidirectional working loop ports. Flow into Port A produces clockwise (CW) shaft rotation; flow into Port B produces counterclockwise (CCW) rotation (viewed from shaft end).
Port L17/8-14 UNF, 1-1/16-12 UN, or 1-5/16-12 UN O-ring boss3.0 bar [44 psi] continuous / 5.0 bar [73 psi] cold startPrimary case drain outlet port. Must be plumbed from the uppermost physical port location back to the reservoir to ensure complete housing fluid immersion.
Port L2Identical nominal thread size to Port L13.0 bar [44 psi] continuous / 5.0 bar [73 psi] cold startSecondary / alternate case drain port. Enables horizontal, vertical, or inverted installation flexibility without case air trapping.
Port M19/16-18 UNF-2B SAE J1926 straight thread O-ring boss480 bar [7,000 psi]Diagnostic pressure gauge port directly monitoring working pressure at main Port A.
Port M29/16-18 UNF-2B SAE J1926 straight thread O-ring boss480 bar [7,000 psi]Diagnostic pressure gauge port directly monitoring working pressure at main Port B.
Port M39/16-18 UNF-2B SAE J1926 straight thread O-ring boss35 bar [500 psi]Low-loop charge pressure diagnostic port for loop flushing verification.
Port X1 (Variable Only)7/16-20 UNF-2B SAE J1926 straight thread O-ring boss40 bar [580 psi]Hydraulic pilot control port for two-position displacement shifting (PT control). Minimum 4.1 bar [60 psi] differential over case pressure required for minimum displacement shift.

| Drive Shaft Spline & Keyed Options

Shaft CodeShaft Style & Tooth ConfigurationPitch / Pressure AngleRated Maximum Torque (N·m [lbf·in])Rated Continuous Torque (N·m [lbf·in])Compatible Frame Sizes
C2Involute Spline, 13 Teeth, ANSI B92.116/32 Pitch, 30° PA340 N·m [3,000 lbf·in]192 N·m [1,700 lbf·in]HYH90M042
C3Involute Spline, 15 Teeth, ANSI B92.116/32 Pitch, 30° PA340 N·m [3,000 lbf·in]192 N·m [1,700 lbf·in]HYH90M042
S1Involute Spline, 14 Teeth, ANSI B92.112/24 Pitch, 30° PA735 N·m [6,500 lbf·in]283 N·m [2,500 lbf·in]HYH90M055, HYH90K055, HYH90V055, HYH90M075, HYH90M100
C6Involute Spline, 21 Teeth, ANSI B92.116/32 Pitch, 30° PA1,130 N·m [10,000 lbf·in]384 N·m [3,400 lbf·in]HYH90M055, HYH90K055, HYH90M075, HYH90M100
C7Involute Spline, 23 Teeth, ANSI B92.116/32 Pitch, 30° PA1,580 N·m [14,000 lbf·in]509 N·m [4,500 lbf·in]HYH90M075, HYH90K075, HYH90M100
F1Heavy Involute Spline, 13 Teeth, ANSI B92.18/16 Pitch, 30° PA1,810 N·m [16,000 lbf·in]746 N·m [6,600 lbf·in]HYH90M100, HYH90M130
F2Long Involute Spline, 13 Teeth, ANSI B92.18/16 Pitch, 30° PA1,810 N·m [16,000 lbf·in]746 N·m [6,600 lbf·in]HYH90M100
C8Heavy Involute Spline, 27 Teeth, ANSI B92.116/32 Pitch, 30° PA2,938 N·m [26,000 lbf·in]814 N·m [7,200 lbf·in]HYH90M130
K1Straight Cylindrical Keyed (∅34.90 mm [∅1.374 in])7.938 mm [0.3125 in] Key768 N·m [6,800 lbf·in]384 N·m [3,400 lbf·in]HYH90M055, HYH90K055
K2Straight Cylindrical Keyed (∅38.07 mm [∅1.499 in])9.525 mm [0.375 in] Key1,130 N·m [10,000 lbf·in]565 N·m [5,000 lbf·in]HYH90M075, HYH90K075
K3Straight Cylindrical Keyed (∅44.42 mm [∅1.749 in])9.525 mm [0.375 in] Key1,582 N·m [14,000 lbf·in]791 N·m [7,000 lbf·in]HYH90M100

Technical Specifications of HENGYUHANG HYH90 Series (Sizes 042 to 130)

4.1 Comprehensive Performance Ratings

Technical ParameterHYH90M042 MFHYH90M055 MF / HYH90K055HYH90V055 MV (Variable)HYH90M075 MF / HYH90K075HYH90M100 MFHYH90M130 MF
Swashplate TypeFixed SwashplateFixed SwashplateVariable Cradle SwashplateFixed SwashplateFixed SwashplateFixed Swashplate
Max. Displacement (cm³/rev [in³/rev])42.0 [2.56]55.0 [3.35]55.0 [3.35] max / Adjustable min75.0 [4.57]100.0 [6.10]130.0 [7.90]
Continuous Rated Speed (Max. Disp.)4,200 rpm3,900 rpm3,900 rpm3,600 rpm3,300 rpm3,100 rpm
Maximum Intermittent Speed (Max. Disp.)4,600 rpm4,250 rpm4,250 rpm3,950 rpm3,650 rpm3,400 rpm
Continuous Rated Speed (Min. Disp.)——4,600 rpm———
Maximum Intermittent Speed (Min. Disp.)——5,100 rpm———
Rated Continuous Pressure420 bar [6,000 psi]420 bar [6,000 psi]420 bar [6,000 psi]420 bar [6,000 psi]420 bar [6,000 psi]420 bar [6,000 psi]
Maximum Peak Pressure480 bar [7,000 psi]480 bar [7,000 psi]480 bar [7,000 psi]480 bar [7,000 psi]480 bar [7,000 psi]480 bar [7,000 psi]
Rated Flow Rate at Rated Speed176 L/min [46 gpm]215 L/min [57 gpm]215 L/min [57 gpm]270 L/min [71 gpm]330 L/min [87 gpm]403 L/min [106 gpm]
Maximum Flow Rate at Max. Speed193 L/min [51 gpm]234 L/min [62 gpm]234 L/min [62 gpm]296 L/min [78 gpm]365 L/min [96 gpm]442 L/min [117 gpm]
Theoretical Specific Torque0.67 N·m/bar [410 lbf·in/1k psi]0.88 N·m/bar [530 lbf·in/1k psi]0.88 N·m/bar [530 lbf·in/1k psi]1.19 N·m/bar [730 lbf·in/1k psi]1.59 N·m/bar [970 lbf·in/1k psi]2.07 N·m/bar [1,260 lbf·in/1k psi]
Maximum Corner Power155 kW [208 hp]187 kW [251 hp]187 kW [251 hp]237 kW [318 hp]292 kW [392 hp]354 kW [475 hp]
Mass Moment of Inertia0.0023 kg·m² [0.0017 slug·ft²]0.0060 kg·m² [0.0044 slug·ft²]0.0060 kg·m² [0.0044 slug·ft²]0.0096 kg·m² [0.0071 slug·ft²]0.0150 kg·m² [0.0111 slug·ft²]0.0230 kg·m² [0.0170 slug·ft²]
Dry Weight (SAE Mount)15 kg [34 lb]22 kg [49 lb]39 kg [86 lb]26 kg [57 lb]34 kg [74 lb]45 kg [99 lb]
Dry Weight (Cartridge Mount)21 kg [46 lb]26 kg [57 lb]40 kg [88 lb]33 kg [72 lb]——

4.2 Pressure, Fluid & Environmental Operational Thresholds

Threshold GroupSpecification
Case Pressure LimitsContinuous allowable case pressure: 3.0 bar [44 psi]; maximum cold start peak pressure: 5.0 bar [73 psi].
Operating Fluid Viscosity RangeMinimum Viscosity (intermittent hot oil): 7.0 mm²/s (7.0 cSt [49 SUS])
Recommended Continuous Working Viscosity: 12.0 to 80.0 mm²/s (12.0 to 80.0 cSt [70 to 370 SUS])
Maximum Cold Start Viscosity: 1,600.0 mm²/s (1,600.0 cSt [7,500 SUS])
Temperature LimitsMinimum Cold Start Temperature: −40 ∘C [−40 ∘F]
Continuous Rated Operating Temperature: 104 ∘C [220 ∘F] (measured at housing drain port)
Maximum Intermittent Peak Temperature: 115 ∘C [240 ∘F]
Fluid Cleanliness & FiltrationStandard Cleanliness: ISO 4406 Class 22/18/13 (SAE J1165) or cleaner.
Suction Filtration Efficiency: β₃₅₋₄₅ =75 (β₁₀ ≥2).
Charge Pressure Filtration Efficiency: β₁₅₋₂₀ =75 (β₁₀ ≥10).
Recommended Suction Screen Mesh: 100 to 125 μm [0.0039 to 0.0049 in]

Advantages

High Power Density with Compact Structural Footprint

The parallel axial piston architecture coupled with lightweight, high-yield spheroidal cast iron housing yields class-leading power-to-weight ratios (up to 7.86 kW/kg [4.80 hp/lb] corner power on HYH90M100), fitting into ultra-tight machine engine compartments and planetary wheel hubs.

Continuous Ultra-High Pressure Operation (420 Bar / 480 Bar Peak)

Engineered for punishing duty cycles, the hydrostatically balanced slipper-swashplate interface and reinforced cylinder block support sustained 420 bar [6,000 psi] continuous and 480 bar [7,000 psi] peak differential pressures without mechanical fatigue or cavitation erosion.

Integrated High-Flow Loop Flushing Valve

Factory-equipped with a built-in shuttle valve and orificed charge pressure relief valve (16 bar cracking pressure), constantly purging contaminated, heated fluid from the low-pressure side of the hydrostatic loop to the external oil cooler, extending bearing and oil life.

Multi-Ratio Two-Position Variable Displacement Capability

The HYH90V055 variable displacement model enables on-the-fly hydraulic (PT) or electrohydraulic (NA/NB/NC/ND) shifting under full load between maximum working displacement and pre-set minimum high-speed travel displacement, providing wide vehicle torque/speed modulation.

Universal Installation Flexibility (SAE & Cartridge Hub Configurations)

Offered with standard SAE B, C, and D 2-bolt/4-bolt pilot flanges as well as recessed cartridge configurations that bolt directly into planetary gearbox housings, optimizing final drive stiffness and eliminating external drive line couplings.

Microprocessor-Compatible Digital Speed & Direction Sensing

Optional digital Hall-effect speed sensor reads pulses from a 48 to 69-pole magnetic ring pressed onto the cylinder barrel, providing bi-directional rotational speed and motion feedback compatible with Danfoss PLUS+1 and standard mobile ECU controllers.

| 6. Cross Reference

Displacement & Frame Compatibility Matrix

HENGYUHANG Model CodeDanfoss / Sauer-Danfoss EquivalentDisplacement (cm³/rev)Mounting Flange StandardPrimary High-Pressure PortsOutput Spline StandardDirect Replacement Status
HYH90M04290M042 NC / NF42.0SAE B 2-Bolt (Ø101.6 mm)3/4 in Code 62 Split Flange13T or 15T 16/32 Pitch100% 1:1 Direct Drop-In
HYH90M05590M055 NC / NF55.0SAE C 4-Bolt (Ø127.0 mm)1.00 in Code 62 Split Flange14T 12/24P or 21T 16/32P100% 1:1 Direct Drop-In
HYH90K05590K055 NC / NF55.0Cartridge Mount (Ø160.0 mm)1.00 in Code 62 Split Flange14T 12/24P or 21T 16/32P100% 1:1 Direct Drop-In
HYH90V05590V055 MV / PT55.0 maxSAE C 4-Bolt (Ø127.0 mm)1.00 in Code 62 Split Flange14T 12/24P or 21T 16/32P100% 1:1 Direct Drop-In
HYH90M07590M075 NC / NF75.0SAE C 4-Bolt (Ø127.0 mm)1.00 in Code 62 Split Flange14T 12/24P, 21T or 23T 16/32P100% 1:1 Direct Drop-In
HYH90K07590K075 NC / NF75.0Cartridge Mount (Ø190.0 mm)1.00 in Code 62 Split Flange14T 12/24P, 21T or 23T 16/32P100% 1:1 Direct Drop-In
HYH90M10090M100 NC / NF100.0SAE C 4-Bolt (Ø127.0 mm)1.00 in Code 62 Split Flange14T 12/24P, 23T 16/32P, 13T 8/16P100% 1:1 Direct Drop-In
HYH90M13090M130 NC / NF130.0SAE D 4-Bolt (Ø152.4 mm)1 1/4 in Code 62 Split Flange13T 8/16P or 27T 16/32P100% 1:1 Direct Drop-In

Control & Loop Flushing Valve Cross-Over

HENGYUHANG Valve CodeOEM Functional DescriptionOEM Control Code ReferenceElectrical / Hydraulic Interface
E4 / E6 / F0 / F3Integral Low-Flow Loop Flushing OrificeDanfoss Series 90 Options E4, E6, F0, F316 bar [232 psi] crack; matched to 8 to 14 cm³ charge pump displacement
G0 / G3 / H0Integral High-Flow Loop Flushing OrificeDanfoss Series 90 Options G0, G3, H016 bar [232 psi] crack; matched to 17 to 65 cm³ charge pump displacement
PTTwo-Position Hydraulic Shift ControlDanfoss Series 90 PT OptionPort X1 hydraulic pilot; min 4.1 bar [60 psi] over case pressure
NA / NCTwo-Position Electrohydraulic Control (MS Connector)Danfoss Series 90 NA (12V) / NC (24V)MS3101A10SL-4P 2-pin circular military connector
NB / NDTwo-Position Electrohydraulic Control (Packard Connector)Danfoss Series 90 NB (12V) / ND (24V)Packard Weather-Pack 2-pin shrouded environmental connector
K03379 / K14956Digital Pulse Speed Sensor KitDanfoss Speed Sensor Assembly4-pin Packard Weather-Pack or Turck Eurofast M12 connector (4.5–8.5 VDC regulated)

| 7. Brand Replacement

The HENGYUHANG HYH90M Series is engineered for direct interchangeability with OEM hydraulic drive motors across major global fluid power manufacturers:

Danfoss / Sauer-Danfoss: Series 90 Fixed & Variable Motors (90M042, 90M055, 90K055, 90V055, 90M075, 90K075, 90M100, 90M130)

Bosch Rexroth: A2FM / A2FE / A10FM Series (Fixed displacement closed-circuit replacements)

Parker Hannifin: Gold Cup Series / Denison M6F, M7F, M11F Hydrostatic Motors

Eaton Vickers: Hydrokraft PVX / MF Series Axial Piston Motors


Linde Hydraulics: HMV / HMF Series Heavy Duty Bent Axis / Swashplate Drive Units

Bondioli & Pavesi: M4MF / M4MV Heavy Duty Axial Piston Motors

Poclain Hydraulics: Hydrostatic secondary drive replacements for closed transmission loops

| 8. Applications

Agricultural Harvesters & Combine Traction Drives: Powers secondary steer-assist axles and primary hydrostatic ground drive wheels on combine harvesters, cotton pickers, and forage cutters, maintaining reliable traction through muddy terrain.

Mobile Construction & Earthmoving Machinery: Acts as primary track drive and wheel propulsion motors on compact track loaders (CTL), skid steer loaders, trenchers, and compact crawler excavators requiring up to 420 bar sustained torque.

Road Building & Compaction Equipment: Drives propulsion and high-frequency vibration drum mechanisms on single-drum and tandem asphalt compactors, motor graders, and cold milling machines operating under continuous vibration.

Horizontal Directional Drilling (HDD) & Tunneling Equipment: Supplies rotary drill head drive torque and carriage thrust travel on pipeline horizontal directional drilling rigs, rotary foundation drilling rigs, and micro-tunneling boring units.

Forestry Timber Processing & Forwarding Equipment: Provides high-torque wheel and track drive power on timber forwarders, wheeled tree harvesters, skidders, and stump grinders working under high mechanical impact loads.

Marine, Offshore & Mining Winch Drives: Mounted via cartridge or standard SAE flanges to drive mooring winches, mining tuggers, anchor windlasses, and offshore crane hoisting drums requiring failsafe closed-loop braking and rapid reverse.

| 9. Packaging & Shipping

Packaging SpecificationStandard ConfigurationExport Protection Detail
Port & Interface SealingHeavy-duty threaded polyethylene blanking plugsAll main ports (A, B), case drains (L1, L2), and gauge ports (M1, M2, M3) hermetically sealed against atmospheric moisture and particulate ingress
Surface Rust PreventionIndustrial corrosion-inhibitor oil spray + primerExterior unpainted surfaces, pilot diameters, and drive shaft splines treated with VCI anti-corrosion barrier grease
Inner Protective BarrierSealed VCI (Vapor Corrosion Inhibitor) plastic linerVacuum-sealed plastic bag enclosing the entire motor assembly with desiccant packs
Cushioning & PositioningCustom-molded high-density EPE foam cradlesPrecision-contoured top and bottom foam inserts locking the shaft end, mounting flange, and valve cap firmly in place
Outer Shipping ContainerHeavy-duty heat-treated fumigation-free wooden caseReinforced plywood crates compliant with ISPM 15 export regulations, banded with high-tensile steel strapping
Consignment TraceabilityDual-label identification systemWaterproof shipping label on crate exterior; etched stainless steel product serial nameplate riveted to the motor housing

| 10. Why Choose Hengyuhang?

Direct Factory Precision Manufacturing & CNC Excellence: Quanzhou Hengyuhang Power Technology Co., Ltd. operates a high-precision, vertically integrated production campus featuring German and Japanese 5-axis machining centers, horizontal boring mills, and sub-micron diamond cylindrical grinding lines. Cylinder block bores and piston shoes are machined to micro-inch tolerances, maintaining barrel-to-port-plate flatnesses below 0.8 μm and surface finish Ra < 0.2 μm for class-leading volumetric sealing.

100% Full-Cycle Multi-Parameter Factory Inspection: Every HYH90M motor undergoes rigorous automated digital bench testing prior to packaging. Factory testing includes full-speed validation up to 4,200 rpm, continuous pressure holding at 420 bar, intermittent pressure spiking to 480 bar, volumetric efficiency verification (≥94%), mechanical breakaway torque profiling, loop flushing relief valve flow mapping, and high-temperature case leakage measurement recorded in individual digital QA dossiers.

Seamless 1:1 OEM Drop-In Interchangeability: Engineered with precise adherence to Danfoss / Sauer-Danfoss Series 90 geometric standards, HYH90M motors match OEM pilot diameters, bolt circle layouts, shaft lengths, spline profiles, and port centerlines with zero dimensional deviation. Equipment builders and maintenance fleets achieve true plug-and-play installation without modifying existing hydraulic hard plumbing, electrical harnesses, or mounting brackets.

Flexible Engineering Customization & Rapid Prototyping: Supported by senior fluid power design engineers, Hengyuhang provides custom-tailored shaft splines, metric port conversions, specialized displacement limiters, customized loop flushing crack pressures, and dual-displacement shift controls. We support low-MOQ prototype testing, rapid-turnaround OEM custom casting runs, and dedicated reverse-engineering support for legacy machine lines.

Robust Supply Chain, Extensive Inventory & Fast Global Dispatch: We maintain strategic stockpiles of raw ductile iron casting bodies, finished alloy cylinder barrels, bi-metal valve plates, and pre-assembled cartridge kits across all frame sizes (042, 055, 075, 100, 130). Standard models ship within 48 to 72 hours, backed by worldwide express air freight and complete Door-to-Door (DDP) multimodal logistics networks.

12-Month Comprehensive Warranty & Lifetime Technical Support: All HENGYUHANG HYH90M Series axial piston motors carry an unconditional 12-month factory warranty against manufacturing defects. Customers enjoy 24/7 technical assistance, direct fluid power engineering consultations, digital hydraulic circuit review, CAD model verification, and comprehensive lifetime spare parts availability.

HENGYUHANG Axial Piston Motors HYH90M Series

HENGYUHANG Axial Piston Motors HYH90M Series are high-pressure, heavy-duty axial piston hydraulic motors designed for advanced closed-circuit hydrostatic transmissions. Built with parallel axial pistons, brass-slipper rotary groups, and heavy-duty tapered roller shaft bearings, the series is available in both fixed displacement (HYH90MF, covering six frame sizes: 30, 42, 55, 75, 100, and 130 cm³/rev) and variable displacement (HYH90MV cradle swashplate, sizes 55 and 75 cm³/rev). Rated for continuous system pressures up to 420 bar (6000 psi) and maximum peak pressures up to 480 bar (7000 psi), HYH90M motors deliver high overall operating efficiency, exceptional rotational speed capability up to 5000 rpm, and bi-directional rotation. Featuring integral loop flushing shuttle valves, charge pressure relief valves, and optional electro-hydraulic or hydraulic two-position displacement controls, the HYH90M Series is custom-engineered to benchmark the technical specifications, mounting interfaces, and port dimensions of Danfoss / Sauer-Sundstrand Series 90 axial piston motors across demanding construction, agricultural, mining, and forestry machinery applications.

Technical Benchmark & Engineering Notice: All performance parameters, dimensional envelopes, pressure ratings, and port sizes presented on this page reference original manufacturer published technical specifications (Sauer-Sundstrand / Danfoss Series 90 Technical Information BLN-10029, Pages 1–25). Replacement units are custom-manufactured; key mounting interfaces, pilot diameters, shaft splines, and hydraulic control settings must be cross-verified against confirmed factory engineering drawings and test certificates prior to final commissioning.

Key Technical & Operational Features

  • Heavy-Duty Swashplate Axial Piston Architecture: High-efficiency parallel piston design with precision spherical slipper retention delivers superior volumetric and mechanical efficiency under continuous cyclic loading in closed-loop hydrostatic drives.

  • High Pressure & Power Density: Robust ductile iron housing supports continuous working pressures up to 420 bar (6000 psi) and maximum peak pressures up to 480 bar (7000 psi), generating up to 354 kW (475 HP) of theoretical corner power on the 130 cm³ frame.

  • Fixed & Variable Displacement Configurations: Available as fixed displacement motors (MF: 030, 042, 055, 075, 100, 130 cm³) or two-position variable displacement motors (MV: 055 and 075 cm³) with stepless cradle swashplate actuation for 2-speed vehicle propel transmissions.

  • Integral Loop Flushing Shuttle & Charge Relief Valve: Built-in loop flushing shuttle spool continuously removes heated, contaminated oil from the low-pressure working loop and directs it across a calibrated charge relief valve into the motor case for active cooling and fluid filtration.

  • High Rotational Speed Capability: Low-inertia rotating cylinder blocks and optimized fluid timing ports allow rated speeds up to 4200 rpm on sizes 030/042, 3900 rpm on size 055, and maximum attainable speeds up to 5000 rpm.

  • Heavy-Duty Shaft Bearings for External Loads: High-capacity tapered roller bearings provide substantial radial and axial side-load capacity, permitting direct pinion, sprocket, or belt drive mounting.

  • Versatile Mounting & Porting Standards: Standard SAE J744 2-bolt and 4-bolt flanges (SAE-B, SAE-C, SAE-D) or 2-bolt Cartridge plug-in flanges for direct planetary gearbox recess mounting, with radial twin ports or axial high-pressure ports (SAE J518 Code 62).

  • Digital Speed Sensor Readiness: Motor housing features a dedicated 9/16-18 O-ring boss port to accommodate non-contact electronic magnetic speed sensors (Packard Weather-Pack connector) for real-time digital closed-loop speed regulation.

Heavy-Duty Industrial & Mobile Applications

The HENGYUHANG HYH90M Series axial piston motor is engineered for demanding closed-circuit hydrostatic propel, winch, and auxiliary drives across a broad range of heavy-duty mobile and stationary machinery:

Earthmoving & Road Construction: Hydrostatic track and wheel propel drives on crawler dozers, asphalt pavers, soil compactors, tandem vibratory rollers, cold planers, and skid-steer loaders.

Agricultural & Harvesting Equipment: Traction propel drives on combine harvesters, self-propelled forage harvesters, sugar beet harvesters, and high-clearance agricultural sprayers.

Mobile Cranes & Marine Winches: Primary and auxiliary high-torque hoist winches, boat davits, dynamic anchor winches, and rotary drill rig rotary head rotation drives.

Forestry & Material Handling: Wheeled log forwarders, timber skidders, rough-terrain heavy forklifts, straddle carriers, and airport container ground-support loaders.

Technical Performance Matrix (OEM Benchmark Reference)

Technical Parameter / Frame SizeHYH90M-030HYH90M-042HYH90M-055HYH90M-075HYH90M-100HYH90M-130
Motor Architecture ExecutionFixed (MF)Fixed (MF)Fixed (MF) / Var (MV)Fixed (MF) / Var (MV)Fixed (MF)Fixed (MF)
Maximum Displacement [cm³/rev / in³/rev]30.0 / 1.8342.0 / 2.5655.0 / 3.3575.0 / 4.57100.0 / 6.10130.0 / 7.93
Minimum Displacement (MV Version) [cm³/rev]––19.0 (19–40)26.0 (26–54)––
Rated Speed at Maximum Displacement [rpm]420042003900360033003100
Rated Speed at Minimum Displacement (MV) [rpm]––46004250––
Maximum Speed at Maximum Displacement [rpm]460046004250395036503400
Maximum Speed at Minimum Displacement (MV) [rpm]––51004700––
Maximum Attainable Speed [rpm]500050004700430040003700
Rated System Pressure [bar / psi]420 / 6000420 / 6000420 / 6000420 / 6000420 / 6000420 / 6000
Maximum Peak System Pressure [bar / psi]480 / 7000480 / 7000480 / 7000480 / 7000480 / 7000480 / 7000
Theoretical Torque at Vg max [Nm/bar]0.480.670.881.191.592.07
Theoretical Torque at Vg max [lbf·in/1000 psi]2904105307309701260
Maximum Rated Input Flow Q max [L/min / gpm]138 / 36193 / 51234 / 62296 / 78365 / 96442 / 117
Maximum Corner Power at Vg max [kW / HP]110 / 149155 / 208187 / 251237 / 318292 / 392354 / 475
Rotating Group Moment of Inertia J [kg·m²]0.00230.00390.00600.00960.01500.0230
Dry Weight (SAE Flange Fixed Motor MF) [kg / lbs]11 / 2415 / 3422 / 4926 / 5734 / 7445 / 99
Dry Weight (Cartridge Fixed Motor) [kg / lbs]–21 / 4626 / 5733 / 72––
Dry Weight (Variable Motor MV) [kg / lbs]––39 / 8644 / 98––

* All technical values referenced from Danfoss Series 90 Technical Information Manual BLN-10029 (Pages 9–10). Theoretical values excluding mechanical and volumetric losses. Operational parameters for custom replacement units are verified through engineering approval drawings and factory dynamometer test certificates prior to dispatch.

Mechanical Installation Interface Specifications

Part 1: Primary mounting flange standards (SAE J744 / Cartridge plug-in), centering pilot diameters, bolt patterns, and ANSI B92.1 / DIN splined drive shafts.

Frame SizePrimary Flange ExecutionCentering Pilot Ø (SAE J744)Bolt Hole Pitch & PatternStandard Splined ShaftSecondary Shaft Options
HYH90M-030SAE-B 2-bolt FlangeØ101.6 mm [4.000 in]146.0 mm pitch / 2x Ø14.3 mm13T 16/32 DP (Code C2)15T 16/32 DP (Code C3)
HYH90M-042SAE-B 2-bolt / Cartridge FlangeØ101.6 mm [4.000 in]146.0 mm pitch / 2x Ø14.3 mm15T 16/32 DP (Code C4)14T 12/24 DP (S1) / 1.375 in Key (K1)
HYH90M-055SAE-C 4-bolt / Cartridge FlangeØ127.0 mm [5.000 in]114.5 mm square / 4x Ø14.7 mm21T 16/32 DP (Code C6)14T 12/24 (S1) / 1.375 in Key (K1) / T1 Taper
HYH90M-075SAE-C 4-bolt / Cartridge FlangeØ127.0 mm [5.000 in]114.5 mm square / 4x Ø14.7 mm21T 16/32 DP (Code C6)23T 16/32 (C7) / DIN 5482 B35×31 (D4) / K2 Key
HYH90M-100SAE-C 4-bolt FlangeØ127.0 mm [5.000 in]114.5 mm square / 4x Ø14.2 mm23T 16/32 DP (Code C7)13T 8/16 DP (F1) / 14T 12/24 (S1) / K3 Key
HYH90M-130SAE-D 4-bolt FlangeØ152.4 mm [6.000 in]161.6 mm square / 4x Ø17.4 mm27T 16/32 DP (Code C8)13T 8/16 DP (F1) / 1.750 in Key (K3)

Fluid Connection & Port Configuration Specifications

Part 2: Main high-pressure ports A & B (SAE J518 Code 62 split flange), case drain outlets, and system gauge ports.

Frame SizeMain Working Ports A & B (Code 62)Port Layout ExecutionsCase Drain Ports L1, L2 (SAE J514)System Gauge Ports M1, M2Loop Flushing Standard
HYH90M-0303/4 in SAE Code 62 (3/8-16 UNC)Radial Twin Ports (Option 8)3/4-14 O-Ring Boss (SAE-12)9/16-18 UNF-2B (SAE-6)Option W (10 to 30 bar charge relief)
HYH90M-0423/4 in SAE Code 62 (3/8-16 UNC)Radial Twin Ports (Option 8)3/4-14 O-Ring Boss (SAE-12)9/16-18 UNF-2B (SAE-6)Option W (10 to 30 bar charge relief)
HYH90M-0551.00 in SAE Code 62 (7/16-14 UNC)Radial (Option 8) or Axial (Option 7)3/4-14 O-Ring Boss (SAE-12)9/16-18 UNF-2B (SAE-6)Option W / A (with calibrated orifice)
HYH90M-0751.00 in SAE Code 62 (7/16-14 UNC)Radial (Option 8) or Axial (Option 7)1 1/16-12 O-Ring Boss (SAE-12)9/16-18 UNF-2B (SAE-6)Option W (10 to 30 bar charge relief)
HYH90M-1001.00 in SAE Code 62 (7/16-14 UNC)Radial (Option 8) or Axial (Option 7)1 1/16-12 O-Ring Boss (SAE-12)9/16-18 UNF-2B (SAE-6)Option W (10 to 30 bar charge relief)
HYH90M-1301.25 in (1 1/4") SAE Code 62 (1/2-13 UNC)Radial Twin Ports (Option 8)1 5/16-12 O-Ring Boss (SAE-16)9/16-18 UNF-2B (SAE-6)Option W (10 to 30 bar charge relief)

Control & Valve Execution Options

Control / Valve CodeExecution & Operating VoltageOperational Principles & Functional Characteristics
Option W / AIntegral Loop Flushing Valve & Charge Relief ValveIntegrated shuttle spool automatically shifts toward the high-pressure side, diverting low-pressure return oil across a built-in charge relief valve into the motor case. Available with factory calibrated charge relief cracking pressures from 10 to 30 bar (e.g. Code 24 = 24 bar [350 psi]). Option A includes calibrated orifice for size 055.
NA / NB (12 VDC)
NC / ND (24 VDC)
Electrohydraulic Two-Position Control
(Max to Min Displacement)
Solenoid-operated two-position displacement control for variable motor (MV). When de-energized, the motor remains at maximum displacement for high tractive rim-pull; energizing the solenoid directs pilot servo pressure to shift swashplate to preset minimum displacement for high-speed travel. Connector: MS (NA/NC) or Packard Weather-Pack (NB/ND).
PTHydraulic Two-Position Control
(Pilot Pressure 12 to 35 bar)
Hydraulically actuated two-position displacement control for variable motor (MV). Application of external hydraulic pilot pressure (12 to 35 bar [175 to 510 psi]) shifts the motor from maximum displacement to calibrated minimum displacement.
EAA / EBAElectronic Speed Sensor Preparation / MountedNon-contact magnetic pulse pickup mounted in the motor housing (Packard Weather-Pack connector). EAA for fixed motors (sizes 030–100); EBA for variable motors (sizes 055–075). Provides digital frequency feedback for vehicle speedometers and closed-loop electronic controllers.

HENGYUHANG HYH90M Series Ordering Code Structure

Pos.Code SegmentAvailable OptionsDescription & Engineering Specifications
01Product SeriesHYH90Series 90 closed-circuit axial piston hydraulic motor technology
02Motor ArchitectureM
K
V
C
SAE Flange Fixed Displacement Motor (Bi-directional rotation)
Cartridge Plug-in Flange Fixed Displacement Motor (Bi-directional)
SAE Flange Variable Displacement Motor (Bi-directional rotation)
Cartridge Plug-in Flange Variable Displacement Motor (Bi-directional)
03Displacement Size030 / 042
055 / 075
100 / 130
Displacement: 30 cm³ [1.83 in³] / 42 cm³ [2.56 in³]
Displacement: 55 cm³ [3.35 in³] / 75 cm³ [4.57 in³]
Displacement: 100 cm³ [6.10 in³] / 130 cm³ [7.93 in³]
04Control Option (Variable)NN
NA / NB
NC / ND
PT
Not applicable (Fixed displacement motor, Code NN)
Electrohydraulic two-position 12 VDC (NA = MS connector; NB = Packard WP)
Electrohydraulic two-position 24 VDC (NC = MS connector; ND = Packard WP)
Hydraulic two-position pilot control (pilot pressure 12 to 35 bar)
05Mounting / Control Option0
2
Cartridge motor configuration (no external bracket)
SAE flange motor configuration
06End Cap Ports8
7
Radial twin ports, SAE J518 Code 62 split flange boss (standard on all sizes)
Axial ports, SAE J518 Code 62 split flange boss (available on sizes 055, 075, 100)
07Minimum Displacement (MV)019 to 040
026 to 054
NNN
Minimum displacement setting in cm³ for size 055 (e.g. 019 = 19 cm³/rev)
Minimum displacement setting in cm³ for size 075 (e.g. 026 = 26 cm³/rev)
Not applicable for fixed displacement motors
08Drive Shaft ConfigurationC2 / C3 / C4
C6 / C7 / C8
F1 / F2
S1 / K1 / T1
13T 16/32 DP (C2), 15T 16/32 DP (C3 on 030/055; C4 on 042/075)
21T 16/32 DP (C6 on 055/075), 23T (C7 on 075/100), 27T (C8 on 130)
13T 8/16 DP standard spline (F1 on 100/130) or long spline (F2 on 100)
14T 12/24 DP (S1), Straight Keyed (K1/K2/K3), Tapered Keyed (T1/T2)
09Loop Flushing SystemW
A
N / X
With integral loop flushing shuttle and charge relief valve (standard)
With loop flushing valve and calibrated orifice (size 055 only)
Without loop flushing valve (defeated, Code N) or no loop flushing (Code X)
10Charge Pressure Setting10 to 30
00
Charge relief pressure setting in bar (e.g. 24 = 24 bar [350 psi]; 20 = 20 bar)
None / defeated (used with loop flushing option N)
11Special Hardware FeatureNNN
EAA / EBA
Standard hardware execution (without electronic speed sensor)
Speed sensor installed with Packard Weather-Pack connector (EAA for MF; EBA for MV)

Example Standard Order Codes: HYH90M055-NC0N-8-NNN-C6-W-24-NNN (55 cm³, Fixed Motor, SAE-C Flange, Radial Ports, 21T Spline, Loop Flushing set at 24 bar) or HYH90V075-NB2N-8-026-S1-W-24-NNN (75 cm³, Variable Motor, 12V Packard EDC Control, Radial Ports, Min Disp 26 cm³, 14T Spline, Loop Flushing set at 24 bar).

OEM Cross-Reference & Compatibility Reference Matrix

HENGYUHANG HYH90M Series axial piston motors are custom-engineered to match OEM Danfoss / Sauer-Sundstrand Series 90 mounting pilots, shaft splines, port locations, and loop flushing options. Mechanical interchangeability should be cross-verified against OEM reference drawings for specific machine serial numbers:

OEM Danfoss Model CodeHENGYUHANG Benchmarked ModelDisplacement & FlangeShaft Spline & PortsLoop Flushing SettingCompatibility Status
90M030-NC0N-8-NNN-C2-W-20-NNNHYH90M030-NC0N-8-NNN-C2-W-20-NNN30 cm³, SAE-B 2-bolt13T 16/32 DP, Radial 3/4"Loop Flushing 20 barBenchmarked Equivalent (Verify Fit)
90M042-NC0N-8-NNN-C4-W-24-NNNHYH90M042-NC0N-8-NNN-C4-W-24-NNN42 cm³, SAE-B 2-bolt15T 16/32 DP, Radial 3/4"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M055-NC0N-8-NNN-C6-W-24-NNNHYH90M055-NC0N-8-NNN-C6-W-24-NNN55 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M075-NC0N-8-NNN-C6-W-24-NNNHYH90M075-NC0N-8-NNN-C6-W-24-NNN75 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M100-NC0N-8-NNN-C7-W-24-NNNHYH90M100-NC0N-8-NNN-C7-W-24-NNN100 cm³, SAE-C 4-bolt23T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M130-NC0N-8-NNN-C8-W-24-NNNHYH90M130-NC0N-8-NNN-C8-W-24-NNN130 cm³, SAE-D 4-bolt27T 16/32 DP, Radial 1.25"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90V055-NB2N-8-019-S1-W-24-NNNHYH90V055-NB2N-8-019-S1-W-24-NNN55 cm³ Var, SAE-C 4-bolt14T 12/24 DP, Min 19 cm³12V EDC Control + FlushBenchmarked Equivalent (Verify Fit)
90V075-NB2N-8-026-S1-W-24-NNNHYH90V075-NB2N-8-026-S1-W-24-NNN75 cm³ Var, SAE-C 4-bolt14T 12/24 DP, Min 26 cm³12V EDC Control + FlushBenchmarked Equivalent (Verify Fit)

Hydraulic Commissioning & Installation Guidelines

1. Initial Casing Pre-filling & Air Bleeding: Before initial operation, the motor housing must be pre-filled with clean, filtered hydraulic oil through the highest positioned case drain port (L1 or L2) and thoroughly deaerated. Dry startup will cause immediate boundary friction damage to the brass piston slippers and valve plate.

2. Housing Drain Line Routing & Pressure Limits: Case drain lines must be piped directly back to the reservoir below minimum fluid level without check valves or restrictive fittings. Continuous case pressure must not exceed 3.0 bar [40 psi] (cold start transient maximum ≤ 5.0 bar [75 psi]; minimum case pressure ≥ 0.3 bar [4 psi] to ensure bearing lubrication).

3. Loop Flushing Pressure Coordination: When pairing HYH90M motors with Series 90 variable pumps, ensure the motor charge pressure relief valve setting matches the pump charge pressure setting (typically 20 or 24 bar). Setting the motor relief valve too low will cause excessive loop flushing flow, depleting system servo pressure.

4. Fluid Cleanliness Standard: Maintain fluid cleanliness according to ISO 4406 at 22/18/13 or cleaner (utilizing charge pressure filtration with β15-20 ≥ 75). Contaminated fluid will accelerate barrel face scoring and cause loop flushing shuttle valve sticking.

5. Fluid Viscosity & Operating Temperature: Recommended operating viscosity is νopt = 12 to 60 mm²/s [70 to 278 SUS] (minimum allowable 7 mm²/s [49 SUS]; cold-start maximum 1600 mm²/s [7500 SUS]). Continuous operating oil temperature should remain below 104 °C [220 °F] (intermittent peak ≤ 115 °C [240 °F]).

Data Verification & Technical Notes

Reference Benchmark Datasheet: Sauer-Sundstrand / Danfoss Technical Information Manual (Document Ref: BLN-10029, Edition 0695 H), Pages 1–25 (Axial Piston Fixed and Variable Displacement Motors Series 90).

Quality Assurance & Dynamometer Testing: Every HENGYUHANG HYH90M motor undergoes 100% full-loop hydraulic test-stand validation for volumetric efficiency, starting torque, casing leakage, and loop flushing relief valve cracking accuracy under 420 bar rated and 480 bar peak pressure prior to dispatch.

Custom Engineering & Tailored Configurations: HENGYUHANG offers custom drive shaft spline lengths, special charge relief pressure springs, tailored orifice combinations, customized auxiliary through-drive coupling sleeves, and PLUS+1 compatible solenoid resistance ratings. Critical mounting dimensions, pilot tolerances, and hydraulic circuit parameters should be cross-verified against OEM reference drawings for specific machine serial numbers.

SEO Meta Title: HYH90M Series Axial Piston Motors | Danfoss Series 90 Replacement | Hengyuhang

SEO Meta Keywords: HYH90M, Danfoss Series 90 replacement, Sauer Danfoss 90M motor, axial piston fixed motor, axial piston variable motor, 90M030, 90M042, 90M055, 90M075, 90M100, 90M130, 90V055, 90V075, closed circuit hydrostatic motor, loop flushing valve, Hengyuhang hydraulic

SEO Meta Description: HENGYUHANG HYH90M Series axial piston fixed and variable displacement hydraulic motors for closed hydrostatic transmissions. Benchmarked replacement for Danfoss Series 90 (displacements 30 to 130 cm³). Rated pressures up to 420 bar, peak 480 bar, swashplate design, integral loop flushing, SAE-B/C/D and cartridge mounting.

Technical Performance Matrix (OEM Benchmark Reference)

Technical Parameter / Frame SizeHYH90M-030HYH90M-042HYH90M-055HYH90M-075HYH90M-100HYH90M-130
Motor Architecture ExecutionFixed (MF)Fixed (MF)Fixed (MF) / Var (MV)Fixed (MF) / Var (MV)Fixed (MF)Fixed (MF)
Maximum Displacement [cm³/rev / in³/rev]30.0 / 1.8342.0 / 2.5655.0 / 3.3575.0 / 4.57100.0 / 6.10130.0 / 7.93
Minimum Displacement (MV Version) [cm³/rev]––19.0 (19–40)26.0 (26–54)––
Rated Speed at Maximum Displacement [rpm]420042003900360033003100
Rated Speed at Minimum Displacement (MV) [rpm]––46004250––
Maximum Speed at Maximum Displacement [rpm]460046004250395036503400
Maximum Speed at Minimum Displacement (MV) [rpm]––51004700––
Maximum Attainable Speed [rpm]500050004700430040003700
Rated System Pressure [bar / psi]420 / 6000420 / 6000420 / 6000420 / 6000420 / 6000420 / 6000
Maximum Peak System Pressure [bar / psi]480 / 7000480 / 7000480 / 7000480 / 7000480 / 7000480 / 7000
Theoretical Torque at Vg max [Nm/bar]0.480.670.881.191.592.07
Theoretical Torque at Vg max [lbf·in/1000 psi]2904105307309701260
Maximum Rated Input Flow Q max [L/min / gpm]138 / 36193 / 51234 / 62296 / 78365 / 96442 / 117
Maximum Corner Power at Vg max [kW / HP]110 / 149155 / 208187 / 251237 / 318292 / 392354 / 475
Rotating Group Moment of Inertia J [kg·m²]0.00230.00390.00600.00960.01500.0230
Dry Weight (SAE Flange Fixed Motor MF) [kg / lbs]11 / 2415 / 3422 / 4926 / 5734 / 7445 / 99
Dry Weight (Cartridge Fixed Motor) [kg / lbs]–21 / 4626 / 5733 / 72––
Dry Weight (Variable Motor MV) [kg / lbs]––39 / 8644 / 98––

* All technical values referenced from Danfoss Series 90 Technical Information Manual BLN-10029 (Pages 9–10). Theoretical values excluding mechanical and volumetric losses. Operational parameters for custom replacement units are verified through engineering approval drawings and factory dynamometer test certificates prior to dispatch.

HENGYUHANG HYH90M Series Ordering Code Structure

Pos.Code SegmentAvailable OptionsDescription & Engineering Specifications
01Product SeriesHYH90Series 90 closed-circuit axial piston hydraulic motor technology
02Motor ArchitectureM
K
V
C
SAE Flange Fixed Displacement Motor (Bi-directional rotation)
Cartridge Plug-in Flange Fixed Displacement Motor (Bi-directional)
SAE Flange Variable Displacement Motor (Bi-directional rotation)
Cartridge Plug-in Flange Variable Displacement Motor (Bi-directional)
03Displacement Size030 / 042
055 / 075
100 / 130
Displacement: 30 cm³ [1.83 in³] / 42 cm³ [2.56 in³]
Displacement: 55 cm³ [3.35 in³] / 75 cm³ [4.57 in³]
Displacement: 100 cm³ [6.10 in³] / 130 cm³ [7.93 in³]
04Control Option (Variable)NN
NA / NB
NC / ND
PT
Not applicable (Fixed displacement motor, Code NN)
Electrohydraulic two-position 12 VDC (NA = MS connector; NB = Packard WP)
Electrohydraulic two-position 24 VDC (NC = MS connector; ND = Packard WP)
Hydraulic two-position pilot control (pilot pressure 12 to 35 bar)
05Mounting / Control Option0
2
Cartridge motor configuration (no external bracket)
SAE flange motor configuration
06End Cap Ports8
7
Radial twin ports, SAE J518 Code 62 split flange boss (standard on all sizes)
Axial ports, SAE J518 Code 62 split flange boss (available on sizes 055, 075, 100)
07Minimum Displacement (MV)019 to 040
026 to 054
NNN
Minimum displacement setting in cm³ for size 055 (e.g. 019 = 19 cm³/rev)
Minimum displacement setting in cm³ for size 075 (e.g. 026 = 26 cm³/rev)
Not applicable for fixed displacement motors
08Drive Shaft ConfigurationC2 / C3 / C4
C6 / C7 / C8
F1 / F2
S1 / K1 / T1
13T 16/32 DP (C2), 15T 16/32 DP (C3 on 030/055; C4 on 042/075)
21T 16/32 DP (C6 on 055/075), 23T (C7 on 075/100), 27T (C8 on 130)
13T 8/16 DP standard spline (F1 on 100/130) or long spline (F2 on 100)
14T 12/24 DP (S1), Straight Keyed (K1/K2/K3), Tapered Keyed (T1/T2)
09Loop Flushing SystemW
A
N / X
With integral loop flushing shuttle and charge relief valve (standard)
With loop flushing valve and calibrated orifice (size 055 only)
Without loop flushing valve (defeated, Code N) or no loop flushing (Code X)
10Charge Pressure Setting10 to 30
00
Charge relief pressure setting in bar (e.g. 24 = 24 bar [350 psi]; 20 = 20 bar)
None / defeated (used with loop flushing option N)
11Special Hardware FeatureNNN
EAA / EBA
Standard hardware execution (without electronic speed sensor)
Speed sensor installed with Packard Weather-Pack connector (EAA for MF; EBA for MV)

Example Standard Order Codes: HYH90M055-NC0N-8-NNN-C6-W-24-NNN (55 cm³, Fixed Motor, SAE-C Flange, Radial Ports, 21T Spline, Loop Flushing set at 24 bar) or HYH90V075-NB2N-8-026-S1-W-24-NNN (75 cm³, Variable Motor, 12V Packard EDC Control, Radial Ports, Min Disp 26 cm³, 14T Spline, Loop Flushing set at 24 bar).

OEM Cross-Reference & Compatibility Reference Matrix

HENGYUHANG HYH90M Series axial piston motors are custom-engineered to match OEM Danfoss / Sauer-Sundstrand Series 90 mounting pilots, shaft splines, port locations, and loop flushing options. Mechanical interchangeability should be cross-verified against OEM reference drawings for specific machine serial numbers:

OEM Danfoss Model CodeHENGYUHANG Benchmarked ModelDisplacement & FlangeShaft Spline & PortsLoop Flushing SettingCompatibility Status
90M030-NC0N-8-NNN-C2-W-20-NNNHYH90M030-NC0N-8-NNN-C2-W-20-NNN30 cm³, SAE-B 2-bolt13T 16/32 DP, Radial 3/4"Loop Flushing 20 barBenchmarked Equivalent (Verify Fit)
90M042-NC0N-8-NNN-C4-W-24-NNNHYH90M042-NC0N-8-NNN-C4-W-24-NNN42 cm³, SAE-B 2-bolt15T 16/32 DP, Radial 3/4"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M055-NC0N-8-NNN-C6-W-24-NNNHYH90M055-NC0N-8-NNN-C6-W-24-NNN55 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M075-NC0N-8-NNN-C6-W-24-NNNHYH90M075-NC0N-8-NNN-C6-W-24-NNN75 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M100-NC0N-8-NNN-C7-W-24-NNNHYH90M100-NC0N-8-NNN-C7-W-24-NNN100 cm³, SAE-C 4-bolt23T 16/32 DP, Radial 1.00"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90M130-NC0N-8-NNN-C8-W-24-NNNHYH90M130-NC0N-8-NNN-C8-W-24-NNN130 cm³, SAE-D 4-bolt27T 16/32 DP, Radial 1.25"Loop Flushing 24 barBenchmarked Equivalent (Verify Fit)
90V055-NB2N-8-019-S1-W-24-NNNHYH90V055-NB2N-8-019-S1-W-24-NNN55 cm³ Var, SAE-C 4-bolt14T 12/24 DP, Min 19 cm³12V EDC Control + FlushBenchmarked Equivalent (Verify Fit)
90V075-NB2N-8-026-S1-W-24-NNNHYH90V075-NB2N-8-026-S1-W-24-NNN75 cm³ Var, SAE-C 4-bolt14T 12/24 DP, Min 26 cm³12V EDC Control + FlushBenchmarked Equivalent (Verify Fit)

RELATED PRODUCTS

Get a Quote

HENGYUHANG Power Technology Co., LTD

Location

No. 173, Xiacuo, Sihuang Village, Xiamei Town, Nan 'an City, Fujian Province

Make a Call

+86 19918575358

WhatsApp Email +86 19918575358