Piston Motors

HENGYUHANG Axial Piston Motors HYHT90M

HENGYUHANG HYHT90M Series axial piston fixed displacement motors provide heavy-duty bidirectional hydrostatic drive power for closed-circuit transmissions, incorporating an optimized 9-piston rotating group, fixed swashplate architecture, and an integrated high-efficiency loop flushing valve engineered for continuous 350 bar [5,076 psi] and 420 bar [6,092 psi] peak operation with high mechanical starting torque.

| Applications

Engineered specifically for demanding mobile and industrial off-highway equipment, the HYHT90M Series delivers high-torque rotary drive power for 6–18 m³ transit concrete mixer drum gearboxes (TMG series), vibratory and propel circuits on road compactors, combine harvester traction drives, and heavy-duty closed-loop winches.

| Key Technical Specifications

Product Model: HENGYUHANG HYHT90M Series (HYHT90M055 / HYHT90M075 / HYHT90M100)

Brand Replacement: Danfoss / Sauer-Danfoss T90M / 90M Series (OEM or tailored as requested)

Displacement: 55 cm³/rev [3.35 in³/rev], 75 cm³/rev [4.57 in³/rev], 100 cm³/rev [6.10 in³/rev]

Rotation Direction: Bidirectional (Clockwise CW / Counterclockwise CCW reversible)

Speed Range: Up to 3,000–3,500 rpm continuous / 3,200–3,700 rpm maximum

Peak Pressure: 350 bar [5,076 psi] continuous working pressure / 420 bar [6,092 psi] peak maximum pressure

| Overview of HENGYUHANG HYHT90M Series Hydraulic Motors

The HENGYUHANG HYHT90M Series represents a high-power-density family of fixed displacement axial piston motors engineered for closed-circuit hydrostatic transmissions. Sharing core hydraulic design heritage with the world-renowned Series 90 and T90 platforms, the HYHT90M delivers proven durability, high starting and running torque efficiency, and compact packaging for heavy mobile machinery.

The motor utilizes a proven parallel axial piston/slipper rotating group operating against a precision-machined fixed swashplate. High-pressure hydraulic fluid entering through either port drives the 9 pistons axially against the inclined swashplate, generating smooth rotary torque at the output shaft. By alternating fluid flow between Ports A and B from a reversible variable pump (such as the HENGYUHANG HYHT90 or HYH90R/L pump), the motor output shaft instantly and smoothly reverses rotation without requiring external directional valves.

Each HYHT90M motor incorporates an integrated, non-adjustable loop flushing shuttle valve paired with a charge pressure relief valve (nominal 16 bar [232 psi] or 13 bar cracking pressure). This integral circuit continuously bleeds off hot, contaminated fluid from the low-pressure return side of the closed working loop into the motor case, circulating it through external oil coolers and filters to ensure cool, clean fluid replenishment and extended bearing life. Optional Hall-effect digital speed sensors provide precision speed and rotational direction feedback for automated machine control architectures.

| Dimension of HENGYUHANG HYHT90M Series Hydraulic Motors

| Interface Technical Specifications

Interface ElementHYHT90M-055 FrameHYHT90M-075 FrameHYHT90M-100 Frame
Mounting Flange (ISO 3019-1 / SAE J744)SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.7 mm bolt holes on ∅161.9 mm B.C.)SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.7 mm bolt holes on ∅161.9 mm B.C.)SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.2 mm bolt holes on ∅161.9 mm B.C.)
Main Working Ports A & B1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 20.8 mm thread depth)1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 20.8 mm thread depth)1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 20.8 mm thread depth)
Porting Configurations AvailableTwin ported (radial opposite sides) or Axial ported (rear endcap)Twin ported (radial opposite sides) or Axial ported (rear endcap)Twin ported (radial opposite sides) or Axial ported (rear endcap)
Case Drain Outlets (L1, L2)7/8-14 UNF-2B (055) / 1-1/16-12 UN-2B straight thread O-ring boss1-1/16-12 UN-2B straight thread O-ring boss per SAE J5141-1/16-12 UN-2B straight thread O-ring boss per SAE J514
System Gauge Ports (M1, M2)9/16-18 UNF-2B O-ring boss per SAE J5149/16-18 UNF-2B O-ring boss per SAE J5149/16-18 UNF-2B O-ring boss per SAE J514
Charge Gauge Port (M3)9/16-18 UNF-2B O-ring boss per SAE J5149/16-18 UNF-2B O-ring boss per SAE J5149/16-18 UNF-2B O-ring boss per SAE J514
Speed Sensor Port9/16-18 UNF-2B straight thread O-ring boss (plugged or sensor installed)9/16-18 UNF-2B straight thread O-ring boss (plugged or sensor installed)9/16-18 UNF-2B straight thread O-ring boss (plugged or sensor installed)

| Installation Specifications

| Fluid Power Calculation Equations

Input Flow: Q = (Vg · n) / (1000 · ηv)  [l/min]  (Q = (Vg · n) / (231 · ηv)  [US gal/min])

Output Torque: M = (Vg · Δp · ηm) / (20 · π)  [N·m]  (M = (Vg · Δp · ηm) / (2 · π)  [lbf·in])

Output Power: P = (M · n · π) / 30,000 = (Q · Δp · ηt) / 600  [kW]  (P = (M · n · π) / 198,000 = (Q · Δp · ηt) / 1714  [hp])

Motor Speed: n = (Q · 1000 · ηv) / Vg  [min⁻¹ / rpm]  (n = (Q · 231 · ηv) / Vg  [min⁻¹ / rpm])

Where:

Vg: Displacement per revolution (cm³/rev or in³/rev)

Δp: Differential system pressure across main ports, pinlet − poutlet  (bar or psi)

n: Shaft rotational speed (min⁻¹ / rpm)

ηv: Volumetric efficiency (≥0.94)

ηm: Mechanical efficiency (≥0.92)

ηt: Overall efficiency, ηv · ηm

| Port Identification & Fluid Flow Direction

Working PortInflow DirectionResulting Shaft Rotation (Viewed from Drive Shaft End)Outflow Port
Port AHigh-pressure fluid inletCounterclockwise (CCW)Port B (Low-pressure return)
Port BHigh-pressure fluid inletClockwise (CW)Port A (Low-pressure return)

| Drive Shaft Matrix & External Moment Limits

External moments (Me) and radial side loads (Re) imposed on the motor shaft by direct gear meshes, misaligned couplings, or cardan joints are subject to strict allowable thresholds to ensure full L20 bearing fatigue life:

Frame SizeMax Allowable External Moment Me (N·m)Available Output Shaft SplinesSpline Specifications (ANSI B92.1-1970 Class 5)Max Allowable Torque Rating (N·m [lbf·in])
HYHT90M-055101 N·mC6: 21-Tooth Spline; S1: 14-Tooth Spline; K1: Straight Keyed21T 16/32 DP (30° PA); 14T 12/24 DP (30° PA)C6: 1,130 N·m [10,000 lbf·in]; S1: 735 N·m [6,500 lbf·in]
HYHT90M-075118 N·mC7: 23-Tooth Spline; C6: 21-Tooth Spline; S1: 14-Tooth Spline; K2: Keyed23T 16/32 DP (30° PA); 21T 16/32 DP (30° PA)C7: 1,580 N·m [14,000 lbf·in]; C6: 1,130 N·m [10,000 lbf·in]
HYHT90M-100126 N·mC7: 23-Tooth Spline; F1/F2: 13-Tooth Spline; S1: 14-Tooth Spline; K3: Keyed23T 16/32 DP (30° PA); 13T 8/16 DP (30° PA)F1/F2: 1,810 N·m [16,000 lbf·in]; C7: 1,580 N·m [14,000 lbf·in]

Technical Specifications of HENGYUHANG HYHT90M Series (Sizes 055 to 100)

4.1 Comprehensive Operating Parameter Matrix

Parameter MetricUnitHYHT90M-055 FrameHYHT90M-075 FrameHYHT90M-100 Frame
Geometric Displacementcm³/rev [in³/rev]55.0 [3.35]75.0 [4.57]100.0 [6.10]
Continuous Rated Speedmin⁻¹ (rpm)3,5003,1503,000
Maximum Intermittent Speedmin⁻¹ (rpm)3,7003,3503,200
Rated Flow @ Rated Speedl/min [US gpm]175 [46]236 [62]300 [79]
Maximum Flow @ Max Speedl/min [US gpm]185 [49]251 [66]320 [85]
Maximum Working Pressure (Continuous)bar [psi]350 [5,076]350 [5,076]350 [5,076]
Maximum System Pressure (Peak Spike)bar [psi]420 [6,092]420 [6,092]420 [6,092]
Maximum Corner Power RatingkW [hp]142 [190]175 [235]224 [300]
Theoretical Torque OutputN·m/bar [lbf·in/1000 psi]0.88 [530]1.19 [730]1.59 [970]
Mass Moment of Inertia (Rotating Group)kg·m² [slug·ft²]0.0060 [0.0044]0.0096 [0.0071]0.0150 [0.0111]
Dry Weight (SAE C Mount)kg [lb]22 [49]26 [57]34 [74]
Case Pressure (Continuous / Cold Peak)bar [psi]3.0 [44] continuous / 5.0 [73] cold start3.0 [44] continuous / 5.0 [73] cold start3.0 [44] continuous / 5.0 [73] cold start
Loop Flushing Relief Cracking Pressurebar [psi]16 [232] standard / 13 [188] optional16 [232] standard / 13 [188] optional16 [232] standard / 13 [188] optional

4.2 Hydraulic Fluid, Viscosity & Temperature Specifications

Operational ParameterFactory Recommended SpecificationPermissible Extreme / Limit
Operating Viscosity Range12 to 80 mm²/s (cSt) [66 to 370 SUS]Optimum efficiency and bearing hydrodynamic lubrication
Minimum Viscosity (Continuous / Intermittent)7 mm²/s (cSt) [49 SUS] continuous5 mm²/s (cSt) [42 SUS] intermittent (t<1 min)
Maximum Cold Start Viscosity1,600 mm²/s (cSt) [7,500 SUS]Permitted at p≤50 bar, n≤1,000 rpm, t>3 min
Operating Temperature Range60 ∘C to 85 ∘C [140 ∘F to 185 ∘F]Continuous maximum 104 ∘C; intermittent ceiling 115 ∘C
Minimum Cold Start Temperature−40 ∘C [−40 ∘F]Pre-warming protocol required prior to high-speed operation
Fluid Cleanliness RequirementISO 4406 Class 22/18/13 (SAE J1165)Filtration beta ratio β₁₅₋₂₀ ≥75 (β₁₀ ≥10)

Advantages

High-Efficiency 9-Piston Fixed Swashplate Architecture

Engineered with an optimized 9-piston rotating assembly that ensures exceptionally smooth torque output across the entire speed envelope. Low torque ripple reduces mechanical fatigue on planetary reduction gearboxes, while precision-contoured piston slippers deliver starting torque efficiencies exceeding 91%, preventing vehicle stall during heavy slope starts.

Ultra-Compact Length & Lightweight Ductile Iron Housing

Designed with concentrated porting passages and an integrated valve endcap, the HYHT90M weighs merely 22 to 34 kg across its three displacements. Its shortened overall length enables effortless drop-in mounting into restricted mixer truck chassis frames, compact compactor drums, and tight drill rig carriage envelopes.

Integrated High-Flow Loop Flushing Shuttle & Relief System

Features a built-in, non-adjustable shuttle valve and charge relief valve that automatically selects the low-pressure side of the working loop to purge a calibrated volume of hot fluid into the motor case. This continuously removes particulate contamination and thermal build-up, preventing thermal degradation of transmission oil and maintaining consistent viscosity.

Dual Porting Flexibility (Twin Radial or Axial Endcap)

Available with either twin radial side ports or axial rear-entry ports, both complying with ISO 6162 / SAE J518 Code 62 1.00" 6,000 psi high-pressure split flange dimensions. Metric M12x1.75 mounting threads are provided as standard for global mixer truck gearboxes, with optional 7/16-14 UNC threads to match North American specifications.

Robust Heavy-Duty Tapered Roller Output Shaft Bearings

The driveshaft is supported by a rugged pair of high-capacity tapered roller bearings positioned to absorb substantial external overhung bending moments and radial side loads from gear pinions or misaligned couplings, ensuring exceptional L20 bearing fatigue life.

Optional Integrated Digital Hall-Effect Speed Sensor

Offers a factory-installed Hall-effect speed pickup sensor reading an integrated magnetic pulse ring pressed onto the cylinder barrel (52 pulses/rev for size 055, 58 for size 075, and 63 for size 100). Available with Turck Eurofast or Packard Weather-Pack sealed connectors, providing digital direction and velocity signals for closed-loop cruise and drum speed automation.

| 6. Cross Reference

Frame Displacement & Model Code Crossover

HENGYUHANG ModelDanfoss / Sauer-Danfoss EquivalentDisplacement (cm³/rev)Mounting FlangeStandard Drive ShaftMain Work Ports
HYHT90M055T90M055 / 90M05555.0 ccSAE C 4-Bolt (∅127 mm)21T 16/32 DP (C6) / 14T 12/24 DP (S1)1.00 in Code 62 Split Flange
HYHT90M075T90M075 / 90M07575.0 ccSAE C 4-Bolt (∅127 mm)23T 16/32 DP (C7) / 21T 16/32 DP (C6)1.00 in Code 62 Split Flange
HYHT90M100T90M100 / 90M100100.0 ccSAE C 4-Bolt (∅127 mm)23T 16/32 DP (C7) / 13T 8/16 DP (F1/F2)1.00 in Code 62 Split Flange

Hydrostatic Transit Mixer Drive Train Matching

Mixer Drum CapacityHydrostatic Pump ModelHydrostatic Motor ModelPlanetary Gearbox ModelGearbox Ratio (i)Max Output Torque
6–7 m³ DrumHYHT90P055 / T90P055HYHT90M055 / 90M055TMG 51.2 Series101.951,000 N⋅m
8–9 m³ DrumHYHT90P075 / T90P075HYHT90M075 / 90M075TMG 61.2 Series111.561,000 N⋅m
10 m³ DrumHYHT90P100 / T90P100HYHT90M100 / 90M100TMG 61.2 Series111.561,000 N⋅m
12 m³ DrumHYHT90P100 / T90P100HYHT90M100 / 90M100TMG 71.2 Series131.371,000 N⋅m

| 7. Brand Replacement

HENGYUHANG HYHT90M Series motors serve as direct form-fit-function replacements for leading global closed-circuit hydrostatic transmission motors:

Danfoss / Sauer-Danfoss: T90 Series (T90M055, T90M075, T90M100) & Series 90 (90M055, 90M075, 90M100 Fixed Displacement Motors)

Rexroth (Bosch Rexroth): A2FE Series (A2FE56, A2FE63, A2FE80, A2FE90, A2FE107) & A2FM Series Bent-Axis Fixed Motors

Eaton (Danfoss / Vickers): Heavy Duty Model 33, 39, 46, 54, 64 Fixed Displacement Hydrostatic Motors

PMP Pro-Mec: PMH M55, PMH M72, PMH M90 Concrete Mixer Drum Drive Motors

Bondioli & Pavesi: M4MF Series (M4MF50, M4MF65, M4MF90) Closed Circuit Motors

Linde Hydraulics: HMF-02 Series (HMF55, HMF75, HMF105) Fixed Displacement Hydraulic Motors

| 8. Applications

Transit Concrete Mixer Drum Planetary Drives (6–18 m³): Directly bolted to TMG 51.2, TMG 61.2, or TMG 71.2 planetary gearboxes, powering smooth drum charging, transit agitating, and high-torque discharging across standard ready-mix truck fleets.

Road Compactor Propulsion & Vibratory Drives: Powers dual-amplitude eccentric vibratory exciter shafts and main wheel drive planetary hubs on heavy single-drum asphalt and soil compaction rollers.

Agricultural Combine Harvester Ground Propel Systems: Acts as secondary hydrostatic drive motor driving 2-speed or 3-speed manual mechanical transaxles on combine harvesters, cotton pickers, and forage cutters.

Trenchless Horizontal Directional Drilling (HDD) Spindle Drives: Drives high-torque rotary drill heads and carriage pullback winches on directional drilling and micro-tunneling rigs under continuous high-pressure cycles.

Closed-Loop Marine & Mooring Winches: Powers bidirectional anchor handling, mooring winches, and deck cranes requiring smooth, positive creep-speed control and high holding torque.

Heavy-Duty Industrial Shredders & Conveyors: Drives reversible apron feeders, scrap metal shredders, and mining slurry conveyors where rapid bidirectional reversal and extreme pressure shock dampening are critical.

| 9. Packaging & Shipping

Packaging SpecificationStandard ConfigurationExport Protection Detail
Port & Interface SealingHeavy-duty threaded polyethylene blanking plugsWorking ports A & B, case drains L1, L2, and all gauge ports sealed against contamination
Surface Rust PreventionIndustrial corrosion-inhibitor oil spray + primerExterior machined pilot surfaces, flange mounting faces, and drive shaft splines coated with anti-rust grease
Inner Protective BarrierSealed VCI (Vapor Corrosion Inhibitor) plastic linerVacuum-sealed moisture-proof plastic enclosure packed with active industrial desiccant sachets
Cushioning & PositioningCustom-molded high-density EPE foam cradlesPrecision-contoured internal foam cushions immobilizing the motor body, shaft extension, and flushing block
Outer Shipping ContainerHeavy-duty heat-treated fumigation-free wooden caseMulti-ply plywood export crates compliant with ISPM 15 standards, reinforced with high-tensile steel banding
Consignment TraceabilityDual-label identification systemWeatherproof exterior shipping markings; etched stainless steel serial nameplate riveted to motor housing

| 10. Why Choose Hengyuhang?

Direct Factory Precision Manufacturing & Sub-Micron CNC Craftsmanship: Quanzhou Hengyuhang Power Technology Co., Ltd. operates an advanced high-precision manufacturing facility equipped with multi-axis CNC turning-milling centers, horizontal boring centers, and automated spherical grinding units. Critical hydraulic rotating components—including ductile iron cylinder barrels, brass-clad bi-metallic valve plates, high-tensile alloy steel pistons, and nitrided swashplate shoes—are machined to ultra-tight geometric tolerances. We maintain cylinder-to-valve-plate contact flatness within 0.8 μm and surface finish smoothness of Ra < 0.2 μm. By sourcing directly from our factory floor, customers bypass intermediary trading markups, gain full batch-to-batch traceability, and secure rock-solid supply continuity at competitive factory pricing.

100% Digitalized Multi-Parameter Test Bench Quality Verification: Zero unverified motors leave our factory. Every single HYHT90M motor is mounted on our automated digital hydraulic test benches to undergo rigorous pre-shipment performance screening. Our multi-stage dynamic testing protocol evaluates:

Full-range speed testing up to rated continuous and maximum rpm in both CW and CCW rotational directions.

High-pressure endurance holding at continuous 350 bar [5,076 psi] and transient pressure spike verification at 420 bar [6,092 psi].

Starting torque mechanical efficiency certification (≥91%) and overall volumetric efficiency validation (≥94%).

Integrated loop flushing shuttle valve shifting responsiveness and charge pressure relief cracking accuracy (16 bar or 13 bar).

Internal case drain leakage flow measurement under peak operating temperatures (60 °C to 85 °C) to eliminate seal failure risks. Every unit is assigned a permanent engraved serial number linked directly to an individual digital QA test dossier for complete customer peace of mind.

Guaranteed 1:1 OEM Drop-In Interchangeability with Zero Re-Engineering: Engineered strictly to original Danfoss / Sauer-Danfoss T90M and 90M Series geometric, hydraulic, and mechanical interface standards, HENGYUHANG motors provide true plug-and-play field interchangeability. Every critical mounting parameter—including standard ISO 3019-1 / SAE pilot diameters (SAE C ∅127 mm), mounting bolt pitch circles, drive shaft splines (ANSI B92.1 Class 5 21T/23T/14T), Code 62 split flange main ports, and SAE straight-thread O-ring boss ports—matches OEM dimensions down to the millimeter. Ready-mix fleet operators, equipment rebuilders, and hydraulic service centers can replace worn OEM motors in under two hours with zero piping alterations, zero bracket modifications, and zero harness adaptations.

Agile Engineering Customization & Dedicated Application Co-Development: Backed by a team of senior fluid power design engineers with over 15 years of closed-circuit hydrostatic specialization, Hengyuhang provides flexible, tailored engineering services to accommodate unique machine operating requirements:

Customized drive shaft configurations (ANSI involute splines, DIN splines, or straight cylindrical keyed shafts).

Tailored loop flushing relief valve cracking pressures (13 bar to 18 bar) and interchangeable orifice nozzles to balance cooling purge volume against system charge pressure.

Dual porting options: twin radial side ports or rear axial endcap ports with metric M12x1.75 or inch 7/16-14 UNC flange threads.

Factory integration of digital Hall-effect speed sensors (Turck Eurofast or Packard Weather-Pack connectors) calibrated to internal pulse rings.

Low-MOQ prototype support for specialized mobile OEM applications, planetary gearbox adaptations, and legacy machine fleet retrofits.

Strategic Component Inventory, Rapid Dispatch & End-to-End Global Logistics: To minimize machine downtime and lost contractor revenue, Hengyuhang maintains an extensive buffer inventory of semi-finished ductile iron housings, finished rotating barrel groups, valve plates, shaft bearings, and imported FKM/Viton seal kits across all 3 displacements (055, 075, 100). Standard configuration motors ship within 48 to 72 hours of order confirmation. We partner with leading international freight forwarders (DHL, FedEx, UPS) and global maritime carriers to provide complete Door-to-Door (DDP) customs-cleared logistics, transparent tracking, and reliable door delivery across North America, Europe, Southeast Asia, Australia, and South America.

Comprehensive 12-Month Factory Warranty & Lifetime Engineering Support: We stand firmly behind the durability of our hydrostatic products. All HENGYUHANG HYHT90M Series axial piston fixed displacement motors carry an unconditional 12-month factory replacement warranty against manufacturing defects and material failures. In addition to hardware protection, customers enjoy lifetime engineering support from our technical department—including free 2D/3D CAD model verification, hydraulic circuit diagram reviews, commissioning guidance, fluid cleanliness troubleshooting, and guaranteed availability of factory-original maintenance rotating groups, valve plates, and seal repair kits.

HENGYUHANG Axial Piston Fixed Displacement Motors HYHT90M Series

HENGYUHANG Axial Piston Fixed Displacement Motors HYHT90M Series are high-pressure, high-efficiency hydraulic motors engineered for closed-circuit hydrostatic drive transmissions in severe mobile machinery applications. Operating on proven 9-piston in-line rotary group technology with brass slippers and a fixed swashplate, the motor accommodates fluid intake and discharge bi-directionally through either port, enabling seamless clockwise and counterclockwise shaft rotation without external valving. Tailored for extreme cyclic duties—including transit concrete mixer drum drives (6 to 14 m³), vibratory compaction rollers, agricultural harvesting machinery, and heavy winches—the HYHT90M Series is available in three primary displacement sizes: 55 cm³, 75 cm³, and 100 cm³/rev. The motor is rated for continuous working pressures up to 350 bar (5076 psi) and peak operating pressures up to 420 bar (6092 psi), generating up to 224 kW (300 HP) corner power. Equipped with standard SAE-C 4-bolt mounting flanges, ANSI B92.1 splined drive shafts, integrated loop flushing valves with cracking pressure relief, and provisions for hall-effect speed sensors, the HYHT90M Series is custom-manufactured to benchmark the mounting interfaces, performance envelopes, and fluid port configurations of Danfoss / Sauer-Danfoss Series T90 (T90M) fixed displacement axial piston motors.

Technical Benchmark & Engineering Notice: All technical parameters, displacement ratings, rotational speeds, and dimensional interface standards presented on this page reference original manufacturer published technical documentation (Danfoss Power Solutions Series T90 Axial Piston Motors Technical Information Manual BC195786485247en-000302 / former BC00000366, Rev 0302 / August 2021, Pages 1–25; Sauer-Danfoss Series 90 Motor Catalog 11012417 / July 2008, Pages 1–4; and Transit Mixer Systems Brochure L1118131 Rev AA / September 2011, Pages 1–6). Replacement units are custom-manufactured; key mounting interfaces, centering pilots, shaft splines, port threads, and loop flushing orifice settings must be cross-verified against confirmed factory engineering drawings and test certificates prior to final commissioning.

Key Technical & Operational Features

  • Heavy-Duty 9-Piston Cylinder Rotating Group: High-efficiency parallel axial piston rotating assembly featuring brass slippers, hardened spherical cylinder barrel face, and heavy-duty tapered roller bearings engineered to sustain high radial/axial thrust loads and harsh continuous duty cycles.

  • Targeted Transit Mixer Displacements: Manufactured in three standard fixed displacement sizes—55 cm³ (3.35 in³), 75 cm³ (4.57 in³), and 100 cm³ (6.10 in³/rev)—specifically dimensioned to match hydraulic output requirements for 6 m³, 8 m³, 9 m³, 10 m³, and 12–14 m³ concrete transit mixer drums.

  • Bi-Directional Symmetrical Operation: Symmetrical port plate design allows identical speed, torque, and volumetric performance in both clockwise (CW) and counterclockwise (CCW) rotations, ensuring smooth transitions between drum charging (mixing) and discharging.

  • High Operating Pressure & Power Density: Maximum continuous working pressure of 350 bar (5076 psi) with intermittent peak pressure up to 420 bar (6092 psi), delivering continuous output torque up to 1.59 N·m/bar (970 lbf·in/1000 psi) on frame size 100.

  • Integrated Loop Flushing Valve Assembly: Built-in low-pressure loop flushing shuttle valve and calibrated charge relief valve (standard 16 bar cracking pressure; optional 13 bar) continuously divert heated and contaminated fluid from the low-pressure working loop to the motor casing for cooling and filtration.

  • Dual Porting Orientations (Twin Radial or Axial): Available with 1.00 in SAE J518 Code 62 (6000 psi) split-flange ports configured in either same-side twin radial orientation (Option 8 / 8A with M12 metric threads) or rear axial orientation (Option 7) for optimal chassis plumbing clearance.

  • Standardized SAE-C 4-Bolt Mounting: Standard ISO 3019-1 (SAE J744) 127-4 mounting flange with Ø127.0 mm (5.000 in) centering pilot allows direct drop-in mechanical interchangeability with existing transit mixer speed reducers (TMG 51.2 / 61.2 / 71.2).

  • Digital Electronic Speed Sensing Compatibility: Integrated casing sensor cavity accepts non-contact Hall-effect speed and direction sensors (Turck Eurofast or Packard Weather-Pack connectors) pulse-matched to internal target rings (52, 58, or 63 pulses/rev).

Primary Application Fields & Matched System Configurations

The HENGYUHANG HYHT90M Series fixed displacement hydraulic motor is specifically optimized as the secondary drive unit in closed-circuit hydrostatic transmissions across heavy mobile equipment:

Concrete Transit Mixer Trucks: Direct flange mounting onto planetary drum reducers (TMG 51.2 / 61.2 / 71.2) for continuous bi-directional drum rotation, charging, agitation, and discharge across 6 to 14 m³ mixer trucks.

Vibratory Compaction Rollers: Heavy-duty vibratory drum exciter mechanism drives and closed-circuit propel drives on single-drum soil compactors and tandem asphalt rollers.

Agricultural Combines & Forage Harvesters: Ground propulsion assist drives, high-torque threshing cylinder drives, and cutter bar header drives operating under continuous variable load.

Marine & Mobile Hoisting Winches: High-tractive bi-directional winch drum drives on crawler cranes, offshore recovery vessels, and specialized drilling rig drawworks.

Transit Concrete Mixer Drivetrain Matching Reference Table:

Mixer Drum SizeHydraulic Motor ModelMotor DisplacementPaired Variable PumpPaired Drum ReducerReducer Ratio (i)Max Drum Torque
6 – 7 m³ DrumHYHT90M055 (or 90M055)55 cm³/rev [3.35 in³]HYHT90P055 / T90P055TMG 51.2 Planetary101.9 : 151,000 N·m
8 – 9 m³ DrumHYHT90M075 (or 90M075)75 cm³/rev [4.57 in³]HYHT90P075 / T90P075TMG 61.2 Planetary111.5 : 161,000 N·m
10 m³ DrumHYHT90M100 (or 90M100)100 cm³/rev [6.10 in³]HYHT90P100 / T90P100TMG 61.2 Planetary111.5 : 161,000 N·m
12 – 14 m³ DrumHYHT90M100 (or 90M100)100 cm³/rev [6.10 in³]HYHT90P100 / T90P100TMG 71.2 Planetary131.3 : 171,000 N·m

Technical Performance Matrix (OEM Benchmark Reference)

Technical Parameter / Frame SizeHYHT90M-055HYHT90M-075HYHT90M-100
Swashplate ConstructionFixed SwashplateFixed SwashplateFixed Swashplate
Displacement [cm³/rev]55.075.0100.0
Displacement [in³/rev]3.354.576.10
Continuous Operating Speed (max disp) [rpm]350031503000
Maximum Intermittent Speed (max disp) [rpm]370033503200
Maximum Continuous Working Pressure [bar / psi]350 / 5076350 / 5076350 / 5076
Maximum Peak System Pressure [bar / psi]420 / 6092420 / 6092420 / 6092
Rated Input Flow at Rated Speed [L/min / US gpm]175 / 46236 / 62300 / 79
Maximum Flow at Max Speed [L/min / US gpm]185 / 49251 / 66320 / 85
Theoretical Output Torque [N·m/bar]0.881.191.59
Theoretical Output Torque [lbf·in/1000 psi]530730970
Maximum Corner Power [kW / HP]142 / 190175 / 235224 / 300
Dry Weight (SAE-C Flange Mount) [kg / lbs]22 / 4926 / 5734 / 74
Speed Sensor Pulse Rate [pulses per revolution]525863

* All technical values referenced from Danfoss Series T90 Axial Piston Motors Technical Information Manual BC195786485247en-000302 (Pages 7–8). Theoretical torque and flow values exclude mechanical and volumetric efficiency losses. Operational parameters for custom replacement units are verified through confirmed engineering approval drawings and factory dynamometer test certificates prior to dispatch.

Mechanical Installation Interface Specifications

Part 1: Primary mounting flange standards (ISO 3019-1 / SAE J744), centering pilot dimensions, mounting bolt pitch, overall lengths, and ANSI B92.1 splined output shafts.

Frame SizeMounting FlangeCentering Pilot Ø (ISO 3019-1)Bolt Hole Pitch & PatternBody Length to Flange FaceAvailable Output Drive Shafts
HYHT90M-055SAE-C 4-bolt (Flange 127-4)Ø127.0 mm [5.000 in] (+0 / -0.05 mm)114.5 mm [4.51 in] square / 4x Ø14.7 mm228.3 mm (twin) / 228.9 mm (axial)21T 16/32 DP (C6) / 14T 12/24 DP (S1) / 1.375 in Key (K1)
HYHT90M-075SAE-C 4-bolt (Flange 127-4)Ø127.0 mm [5.000 in] (+0 / -0.05 mm)114.5 mm [4.51 in] square / 4x Ø14.7 mm239.8 mm (twin) / 246.1 mm (axial)21T 16/32 DP (C6) / 23T 16/32 DP (C7) / 14T (S1) / 1.50 in Key (K2)
HYHT90M-100SAE-C 4-bolt (Flange 127-4)Ø127.0 mm [5.000 in] (+0 / -0.05 mm)114.5 mm [4.51 in] square / 4x Ø14.2 mm265.7 mm (twin) / 273.3 mm (axial)23T 16/32 DP (C7) / 13T 8/16 DP (F1/F2) / 14T (S1) / 1.75 in Key (K3)

Fluid Connection & Port Configuration Specifications

Part 2: Main working ports A & B (SAE J518 Code 62 4-bolt split flange), case drain connections, loop flushing ports, and system gauge ports.

Frame SizeMain Working Ports A & B (Code 62)Port Layout OptionsCase Drain Ports L1, L2 (SAE J514)Working Gauge Ports M1, M2Charge Gauge Port M3
HYHT90M-0551.00 in (DN25) Code 62 (7/16-14 UNC or M12×1.75)Twin radial (8) or Axial end (7)7/8-14 UNF-2B (SAE-10 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)
HYHT90M-0751.00 in (DN25) Code 62 (7/16-14 UNC or M12×1.75)Twin radial (8) or Axial end (7)1 1/16-12 UN-2B (SAE-12 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)
HYHT90M-1001.00 in (DN25) Code 62 (7/16-14 UNC or M12×1.75)Twin radial (8) or Axial end (7)1 1/16-12 UN-2B (SAE-12 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)9/16-18 UNF-2B (SAE-6 O-Ring Boss)

Loop Flushing & Special Hardware Options

Functional OptionExecution & Setting CodesTechnical Characteristics & Operational Flow Rates
Loop Flushing Valve (Integral)Option Code W (With Valve)
Option Code N / X (Without Valve)
Integral non-adjustable shuttle spool that shifts automatically towards the high-pressure side, connecting the low-pressure side of the working loop to a calibrated charge pressure relief valve. Continuous flushing flow prevents loop overheating and removes wear particles to the reservoir filter.
Flushing Relief Cracking Pressure16 bar ± 8.5% (Standard)
13 bar ± 8.5% (Optional)
Cracking pressure of the internal charge relief valve. Nominal 16 bar [232 psi] setting matches standard Danfoss / Sauer-Danfoss closed-loop charge pressure (20 to 24 bar), ensuring sufficient pilot pressure is maintained for variable pump swashplate control.
Flushing Orifice Options (16 bar Cracking)Code E4: 4.0 L/min
Code E6: 7.0 L/min
Code F0: 11.5 L/min
Code F3: 14.5 L/min
Code G0: 22.0 L/min
Calibrated flushing flow rate at 25 bar differential pressure (low system pressure minus case pressure). Recommended charge pump displacements: 8 cm³ for E4/E6; 11 cm³ for F0; 14 cm³ for F3; 17–20 cm³ for G0. Standard mixer application configuration is Code E6 or F0.
Special Hardware & Valve PlatesMBX / MIX: CP15+0.5°
NNN: Standard Valve Plate
EBA: Speed Sensor (Packard)
CP15 +0.5° pre-compression angle valve plates specifically configured for transit concrete mixer duty cycles to minimize commutation pressure pulsation. Option EBA integrates a Hall-effect magnetic speed sensor with Packard Weather-Pack connector (supply voltage 4.5 to 8.5 VDC regulated).

HENGYUHANG HYHT90M Series Ordering Code Structure

Pos.Code SegmentAvailable OptionsDescription & Engineering Specifications
01Product ArchitectureHYHT90Series T90 heavy-duty axial piston closed-circuit hydraulic motor technology
02Motor Mounting TypeMSAE-C 4-bolt flange mounting, fixed displacement bi-directional motor
03Frame Displacement055
075
100
Displacement: 55.0 cm³/rev [3.35 in³/rev]
Displacement: 75.0 cm³/rev [4.57 in³/rev]
Displacement: 100.0 cm³/rev [6.10 in³/rev]
04Motor Control ExecutionNCFixed displacement motor (non-controlled, fixed swashplate)
05Product Category0Standard fixed displacement motor execution
06Displacement LimitN100% nominal maximum fixed displacement
07Endcap Ports Layout8 / 8A
7
Radial twin ports on same side (8: standard 7/16-14 UNC; 8A: M12×1.75 metric for mixer trucks)
Axial end ports (rear porting orientation, 1.00 in Code 62 split flange)
08Loop Flushing FeatureW
N / X
With integrated loop flushing valve and charge pressure relief valve
Without loop flushing valve (plugged cavity, Code N; unmachined endcap, Code X)
09Loop Flushing Shuttle0Standard symmetrical shuttle spool execution
10Output Drive ShaftC6
C7
F1 / F2
S1
K1 / K2 / K3
21T 16/32 DP spline (C6, available on 055, 075, 100)
23T 16/32 DP spline (C7, available on 075, 100)
13T 8/16 DP spline (F1 standard; F2 long shaft, available on 100)
14T 12/24 DP spline (S1, available on 055, 075, 100)
Straight cylindrical keyed shaft: 1.375 in (K1), 1.500 in (K2), 1.749 in (K3)
11Flushing Valve SelectionW
N
Equipped with loop flushing valve
Without loop flushing valve (option Pos. 16 = "00")
12Loop Flushing Setting16
13
00
16 bar [232 psi] cracking pressure (factory standard)
13 bar [188 psi] cracking pressure
None (without flushing valve)
13Special Hardware FeatureMBX / MIX
NNN
EBA
CP15 +0.5° valve plate for transit mixer duty cycles (MBX / MIX)
Standard hardware configuration without special features (NNN)
Hall-effect magnetic speed sensor with Packard Weather-Pack connector (EBA)
14Flushing Orifice SettingE4 / E6
F0 / F3
G0
00
4.0 L/min (E4) or 7.0 L/min (E6) at 16 bar cracking pressure
11.5 L/min (F0) or 14.5 L/min (F3) at 16 bar cracking pressure
22.0 L/min (G0) high-capacity flushing flow
None (00, without flushing orifice)

Example Standard Order Codes: HYHT90M055-NC0N-8-N-0-C6-W-16-MBX-00-00-E6 (55 cm³, Fixed Motor, Radial Twin Ports, 21T Spline, Loop Flushing with 16 bar Cracking, Mixer Valve Plate, 7 L/min Orifice) or HYHT90M075-NC0N-8A-N-0-C7-W-16-MBX-00-00-F0 (75 cm³, Fixed Motor, Metric M12 Ports for Mixer Truck, 23T Spline, 16 bar Flushing, 11.5 L/min Orifice) or HYHT90M100-NC0N-8A-N-0-F1-W-16-MBX-00-00-F0 (100 cm³, Fixed Motor, Metric M12 Ports, 13T 8/16 DP Spline, 16 bar Flushing, 11.5 L/min Orifice).

OEM Cross-Reference & Compatibility Reference Matrix

HENGYUHANG HYHT90M Series fixed displacement hydraulic motors are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss Series T90 (T90M) and Series 90 (90M) motor mounting flanges, drive shafts, and hydraulic port layouts. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:

OEM Danfoss Model CodeHENGYUHANG Benchmarked ModelDisplacement & FlangeOutput Shaft & PortsLoop Flushing SettingCompatibility Status
T90M055-NC0N-8-N0-C6-W00-MBX-00-00-E6HYHT90M055-NC0N-8-N0-C6-W00-MBX-00-00-E655 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"16 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
T90M075-NC0N-8A-N0-C7-W00-MBX-00-00-F0HYHT90M075-NC0N-8A-N0-C7-W00-MBX-00-00-F075 cm³, SAE-C 4-bolt23T 16/32 DP, Metric M12 8A16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
T90M075-NC0N-7-N0-C6-W00-NNN-00-00-E6HYHT90M075-NC0N-7-N0-C6-W00-NNN-00-00-E675 cm³, SAE-C 4-bolt21T 16/32 DP, Axial End 716 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
T90M100-NC0N-8A-N0-C7-W00-MBX-00-00-F0HYHT90M100-NC0N-8A-N0-C7-W00-MBX-00-00-F0100 cm³, SAE-C 4-bolt23T 16/32 DP, Metric M12 8A16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
T90M100-NC0N-8A-N0-F1-W00-MBX-00-00-F3HYHT90M100-NC0N-8A-N0-F1-W00-MBX-00-00-F3100 cm³, SAE-C 4-bolt13T 8/16 DP, Metric M12 8A16 bar Cracking, 14.5 L/minBenchmarked Equivalent (Verify Fit)
90M055-NC0N-8-N0-C6-W00-NNN-00-00-E6HYHT90M055-NC0N-8-N0-C6-W00-NNN-00-00-E655 cm³, SAE-C 4-bolt21T 16/32 DP, Radial Twin 816 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
90M075-NC0N-8-N0-C7-W00-NNN-00-00-F0HYHT90M075-NC0N-8-N0-C7-W00-NNN-00-00-F075 cm³, SAE-C 4-bolt23T 16/32 DP, Radial Twin 816 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0HYHT90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0100 cm³, SAE-C 4-bolt13T 8/16 DP, Radial Twin 816 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)

Hydraulic Commissioning & Installation Guidelines

1. Initial Casing Pre-filling & Air Purging: Prior to initial startup, the motor housing must be completely pre-filled with clean, filtered hydraulic oil through the highest positioned case drain port (L1 or L2) and thoroughly deaerated. Dry startup will cause instantaneous friction seizure and galling to the brass piston slippers, cylinder barrel face, and valve plate.

2. Housing Drain Plumbing & Pressure Limits: Motor case drain lines must be piped independently and unrestricted back to the hydraulic reservoir below the minimum fluid level. Operating continuous case pressure must not exceed 3.0 bar [44 psi] (cold start transient maximum ≤ 5.0 bar [73 psi]). Excessive casing pressure causes front shaft seal extrusion and oil contamination into planetary gearboxes.

3. Charge Pressure Matching & Low-Loop Protection: Ensure that closed-loop charge pressure is maintained at or above the motor loop flushing cracking pressure (16 bar ± 8.5%) under all operating conditions. Operating below charge pressure limits will cause loop flushing malfunction, swashplate instability on the pump, and rapid cavitation damage.

4. Fluid Cleanliness Standard: Maintain fluid cleanliness strictly according to ISO 4406 at 22/18/13 or cleaner. For transit mixer installations, ensure hydraulic tank breathers and reservoir fill caps are sealed against cement dust and high-pressure pressure-washer spray ingress during vehicle wash-downs.

5. Viscosity & Operating Temperature Range: Recommended operating viscosity is νopt = 12 to 80 mm²/s [66 to 370 SUS] (minimum allowable 7 mm²/s [49 SUS]; cold-start maximum 1600 mm²/s [7500 SUS]). Continuous oil temperature should remain within 60 to 85 °C [140 to 185 °F] (rated maximum 104 °C [220 °F]; intermittent peak ≤ 115 °C [240 °F]).

Data Verification & Technical Notes

Reference Benchmark Datasheets: Danfoss Power Solutions Series T90 Axial Piston Motors Technical Information Manual (Document Ref: BC195786485247en-000302 / former BC00000366, Rev 0302, August 2021 Edition, Pages 1–25); Sauer-Danfoss Series 90 Axial Piston Motors Model Code Selection Guide (Document Ref: 11012417, July 2008 Edition, Pages 1–4); and Sauer-Danfoss Transit Mixer Drivetrain Systems Brochure (Document Ref: L1118131, Rev AA, September 2011 Edition, Pages 1–6).

Quality Inspection & Factory Dyno Testing: Every HENGYUHANG HYHT90M motor is dynamically validated on automated hydraulic test benches for full-load bi-directional volumetric efficiency, starting torque, loop flushing flow calibration, and external leakage under 350 bar continuous and 420 bar peak pressure prior to dispatch.

Custom Engineering & Tailored Configurations: HENGYUHANG provides custom drive shaft splines (C6, C7, F1, F2), specialized metric M12 mixer truck port flanges (Option 8A), tailored loop flushing orifice flow ratings (E4 to G0), and Hall-effect speed sensor integrations. Critical mounting dimensions, pilot tolerances, and hydraulic circuit parameters should be cross-verified against OEM reference drawings for specific machine serial numbers.

SEO Meta Title: HYHT90M Series Axial Piston Fixed Motor | Danfoss T90M Replacement | Hengyuhang

SEO Meta Keywords: HYHT90M, Danfoss T90M replacement, T90 motor, Sauer Danfoss T90M, 90M055, 90M075, 90M100, T90M055, T90M075, T90M100, concrete mixer motor, transit mixer hydraulic motor, fixed displacement axial piston motor, loop flushing motor, Hengyuhang hydraulic

SEO Meta Description: HENGYUHANG HYHT90M Series axial piston fixed displacement hydraulic motors for concrete transit mixer drum drives and heavy closed-loop transmissions. Benchmarked replacement for Danfoss Series T90 / 90M (displacements 55, 75, 100 cm³). Continuous working pressure 350 bar, peak 420 bar, bi-directional rotation, integral loop flushing, SAE-C mounting.

OEM Cross-Reference & Compatibility Reference Matrix

HENGYUHANG HYHT90M Series fixed displacement hydraulic motors are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss Series T90 (T90M) and Series 90 (90M) motor mounting flanges, drive shafts, and hydraulic port layouts. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:

OEM Danfoss Model CodeHENGYUHANG Benchmarked ModelDisplacement & FlangeOutput Shaft & PortsLoop Flushing SettingCompatibility Status
T90M055-NC0N-8-N0-C6-W00-NNN-00-00-E6HYHT90M055-NC0N-8-N0-C6-W00-NNN-00-00-E655 cm³, SAE-C 4-bolt21T 16/32 DP, Radial 1.00"16 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
T90M055-NC0N-7-N0-C6-W00-NNN-00-00-E6HYHT90M055-NC0N-7-N0-C6-W00-NNN-00-00-E655 cm³, SAE-C 4-bolt21T 16/32 DP, Axial End 716 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
T90M075-NC0N-8A-N0-C7-W00-NNN-00-00-F0HYHT90M075-NC0N-8A-N0-C7-W00-NNN-00-00-F075 cm³, SAE-C 4-bolt23T 16/32 DP, Metric M12 8A16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
T90M075-NC0N-8-N0-C7-W00-NNN-00-00-F0HYHT90M075-NC0N-8-N0-C7-W00-NNN-00-00-F075 cm³, SAE-C 4-bolt23T 16/32 DP, Radial 1.00"16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
T90M075-NC0N-7-N0-C6-W00-NNN-00-00-E6HYHT90M075-NC0N-7-N0-C6-W00-NNN-00-00-E675 cm³, SAE-C 4-bolt21T 16/32 DP, Axial End 716 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
T90M100-NC0N-8A-N0-C7-W00-NNN-00-00-F0HYHT90M100-NC0N-8A-N0-C7-W00-NNN-00-00-F0100 cm³, SAE-C 4-bolt23T 16/32 DP, Metric M12 8A16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
T90M100-NC0N-8A-N0-F1-W00-NNN-00-00-F3HYHT90M100-NC0N-8A-N0-F1-W00-NNN-00-00-F3100 cm³, SAE-C 4-bolt13T 8/16 DP, Metric M12 8A16 bar Cracking, 14.5 L/minBenchmarked Equivalent (Verify Fit)
T90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0HYHT90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0100 cm³, SAE-C 4-bolt13T 8/16 DP, Radial 1.00"16 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
90M055-NC0N-8-N0-C6-W00-NNN-00-00-E6HYHT90M055-NC0N-8-N0-C6-W00-NNN-00-00-E655 cm³, SAE-C 4-bolt21T 16/32 DP, Radial Twin 816 bar Cracking, 7.0 L/minBenchmarked Equivalent (Verify Fit)
90M075-NC0N-8-N0-C7-W00-NNN-00-00-F0HYHT90M075-NC0N-8-N0-C7-W00-NNN-00-00-F075 cm³, SAE-C 4-bolt23T 16/32 DP, Radial Twin 816 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)
90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0HYHT90M100-NC0N-8-N0-F1-W00-NNN-00-00-F0100 cm³, SAE-C 4-bolt13T 8/16 DP, Radial Twin 816 bar Cracking, 11.5 L/minBenchmarked Equivalent (Verify Fit)

RELATED PRODUCTS

Get a Quote

HENGYUHANG Power Technology Co., LTD

Location

No. 173, Xiacuo, Sihuang Village, Xiamei Town, Nan 'an City, Fujian Province

Make a Call

+86 19918575358

WhatsApp Email +86 19918575358