Engineered with field-proven A10 swashplate rotary group technology, the HENGYUHANG HYH10FM Series 52 axial piston fixed motor delivers up to 350 bar peak pressure, high rotational speed capability, and direct 1:1 drop-in interchangeability for universal medium-pressure hydrostatic transmissions in open and closed circuits.

| Applications

Tailored for hydrostatic auxiliary drives, cooling fan drives, vibratory compactor drives, sweeper brooms, agricultural machinery, and municipal vehicle systems, the HYH10FM series provides dependable bidirectional power with low operating noise. Its compact SAE 2-bolt mounting envelope and optional integral anti-cavitation valve ensure reliable, shock-free deceleration in high-inertia fan and conveyor circuits.

| Key Technical Specifications

Product Model: HYH10FM Series 52 (Sizes 23, 28, 37, 45, 58, 63)

Brand Replacement: Bosch Rexroth A10FM Series 52 (OEM or tailored as requested)

Displacement: Fixed 23.5 to 63.1 cm³/rev (6 standard frame sizes)

Rotation Direction: Bi-directional / Alternating (W), Clockwise (R), or Counter-clockwise (L)

Speed Range: Up to 4,900 rpm nominal (Size 23), 4,700 rpm (Size 28), 4,200 rpm (Size 37), 4,000 rpm (Size 45), 3,600 rpm (Size 58), 3,400 rpm (Size 63)

Peak Pressure: Nominal p nom = 280 bar (4,100 psi); Maximum peak p max = 350 bar (5,100 psi)

| Overview of HENGYUHANG HYH10FM Series 52 Hydraulic Motors

The HENGYUHANG HYH10FM Series 52 is an all-purpose axial piston fixed displacement motor utilizing an optimized swashplate rotary group for hydrostatic transmissions in both open and closed circuits. Designed as a universal medium-pressure drive, the motor features a high power density, an exceptionally low operating noise profile, and an extended operational service life. With fixed geometric displacements ranging from 23.5 cm³/rev to 63.1 cm³/rev across three modular housing frames, the HYH10FM series is approved for high rotational speeds up to 4,900 rpm. It accommodates diverse mechanical and fluid configurations, including standard SAE 2-bolt mounting flanges (ISO 3019-1), ANSI B92.1a involute splined shafts, metric/UNC SAE Code 62 high-pressure flange ports, threaded metric/UN ports, integrated flushing and boost-pressure valves for heat dissipation in closed loops, and integral anti-cavitation check valves engineered specifically for high-inertia hydraulic fan drive deceleration.

| Dimension of HENGYUHANG HYH10FM Series 52 Hydraulic Motors

11

| Mechanical Mounting & Port Interface Specifications

Frame Size & SeriesSAE Mounting Flange (ISO 3019-1 Standard)Pilot Centering Spigot (∅D1)
HYH10FM23 / 28SAE-B 2-bolt (ISO 101-2)∅101.6 −0.054/0 mm (∅4.0 in)
HYH10FM37 / 45SAE-B 2-bolt (ISO 101-2)∅101.6 −0.054/0 mm (∅4.0 in)
HYH10FM58 / 63SAE-B 2-bolt (ISO 101-2)∅101.6 −0.054/0 mm (∅4.0 in)
Frame Size & SeriesPitch Circle Diameter (PCD) / Bolt HolesStandard Splined Shaft Options (ANSI B92.1a)Work Port Standard (Flange or Threaded)Case Drain Ports (L, L1)
HYH10FM23 / 28∅146 mm / 2× ∅14.3 mm7/8 in 13T 16/32DP (Shaft R) / Tapered Keyed (C)SAE 3/4" (Code 62 / M10 or 3/8-16UNC) / M27×2 / 1 1/16-12UN3/4-16UNF-2B (15 mm deep)
HYH10FM37 / 45∅146 mm / 2× ∅14.3 mm1 in 15T 16/32DP (Shaft R) / 7/8 in 13T (W) / Tapered (C)SAE 3/4" (Code 62 / M10 or 3/8-16UNC) / M27×2 / 1 1/16-12UN7/8-14UNF-2B (17 mm deep)
HYH10FM58 / 63∅146 mm / 2× ∅14.3 mm1 1/4 in 14T 12/24DP (Shaft R) / 1 in 15T (W) / Tapered (C)SAE 3/4" (Code 62 / M10 or 3/8-16UNC) / M27×2 / 1 1/16-12UN7/8-14UNF-2B (17 mm deep)

| Installation Specifications

| Mathematical Operating Characteristics

Inlet Flow Rate: qv = (Vg × n) / (1000 × ηv)  [L/min]

Output Rotational Speed: n = (qv × 1000 × ηv) / Vg  [rpm]

Output Torque: M = (Vg × Δp × ηhm) / (20 × π)  [Nm]

Drive Power: P = (2π × M × n) / 60000 = (qv × Δp × ηt) / 600  [kW]

| Connection Port Identification & Standard Layout

Port IdentifierPort Function / DescriptionPressure Rating (pmax)Applicable Port StandardsConnection State
A, BHigh-Pressure Working Lines (Same Side)280 bar nominal / 350 bar peakISO 6162-2 (SAE Code 62, 3/4") / DIN 3852-1 (M27×2) / ISO 11926 (1 1/16-12UN)Must be connected
LCase Drain Port (Top / Side)2 bar static (4 bar dynamic peak)ISO 11926 (3/4-16UNF-2B or 7/8-14UNF-2B)Connected to reservoir (above fluid level)
L1Case Drain Port (Bottom / Drain)2 bar static (4 bar dynamic peak)ISO 11926 (3/4-16UNF-2B or 7/8-14UNF-2B)Plugged during normal top-drain operation
DST / DSAxSpeed Sensor PortDynamic operating pressureM6 × 1 fastening thread (at least 9 mm deep)Plugged with pressure-tight cap if unused

| Replacement Drive Shaft Interface Matrix (ISO 3019-1 / ANSI B92.1a Standard)

Shaft IdentifierStandard Spline SpecificationApplicable Frame SizesCenter Bore Retention ThreadMaximum Permissible Torque Rating
R (Size 23–28)Splined shaft 7/8 in 13T 16/32DP (ANSI B92.1a)HYH10FM23, HYH10FM281/4-20UNC-2B (usable spline 14.4 mm)105 Nm
C (Size 23–28)Tapered shaft 1:8 with woodruff key (22-3(B))HYH10FM23, HYH10FM285/8-18UNF-2A threaded spigot105 Nm
R (Size 37–45)Splined shaft 1 in 15T 16/32DP (ANSI B92.1a)HYH10FM37, HYH10FM451/4-20UNC-2B (usable spline 18.0 mm)198 Nm
W (Size 37–45)Splined shaft 7/8 in 13T 16/32DP (reduced torque)HYH10FM37, HYH10FM451/4-20UNC-2B (usable spline 16.0 mm)105 Nm
C (Size 37–45)Tapered shaft 1:8 with woodruff key (25-3(B-B))HYH10FM37, HYH10FM45M16 × 1.5 metric threaded spigot198 Nm
R (Size 58–63)Splined shaft 1 1/4 in 14T 12/24DP (ANSI B92.1a)HYH10FM58, HYH10FM635/16-18UNC-2B (usable spline 23.6 mm)281 Nm
W (Size 58–63)Splined shaft 1 in 15T 16/32DP (reduced torque)HYH10FM58, HYH10FM631/4-20UNC-2B (usable spline 16.0 mm)198 Nm
C (Size 58–63)Tapered shaft 1:8 with woodruff key (32-3(C))HYH10FM58, HYH10FM631-12UNF-2A threaded spigot281 Nm

Technical Specifications of HENGYUHANG HYH10FM Series (Sizes 23 to 63)

4.1 Displacement, Rotational Speed, Flow, and Torque Ratings

Technical ParameterUnitHYH10FM23HYH10FM28HYH10FM37HYH10FM45HYH10FM58HYH10FM63
Geometric Displacement (Vgₘₐₓ)cm³/rev (in³/rev)23.5 (1.43)28.5 (1.73)36.7 (2.24)44.5 (2.71)58.0 (3.53)63.1 (3.84)
Nominal Working Pressure (pₙₒₘ)bar (psi)280 (4,100)280 (4,100)280 (4,100)280 (4,100)280 (4,100)280 (4,100)
Maximum Peak Pressure (pₘₐₓ)bar (psi)350 (5,100)350 (5,100)350 (5,100)350 (5,100)350 (5,100)350 (5,100)
Nominal Rotational Speed (nₙₒₘ)rpm4,9004,7004,2004,0003,6003,400
Maximum Inlet Flow (qv max at nₙₒₘ)L/min (gpm)115 (30.4)134 (35.4)154 (40.7)178 (47.0)209 (55.2)215 (56.8)
Drive Power at nₙₒₘ and pₙₒₘ (Pmax)kW (HP)53.6 (71)62.5 (83)71.8 (95)83.1 (111)97.4 (130)100.1 (133)
Output Torque at pₙₒₘ (Mmax)Nm (lb-ft)105 (77.4)127 (93.7)163 (120)198 (146)258 (190)281 (207)
Breakaway Starting Torque approx. (n=0 rpm)Nm (lb-ft)75 (55.3)105 (77.5)125 (92.2)170 (125)205 (151)230 (169)
Rotary Stiffness of Drive Shaft (Shaft R)Nm/rad28,47828,47846,85946,85980,59080,590
Moment of Inertia of Rotary Group (J_TW)kg·m²0.00170.00170.00330.00330.00560.0056
Maximum Angular Acceleration (α)rad/s²5,5005,5004,0004,0003,3003,300
Housing Case Volume (V)L (gal)0.60 (0.16)0.60 (0.16)0.70 (0.18)0.70 (0.18)0.80 (0.21)0.80 (0.21)
Dry Weight approx.kg (lbs)12.0 (26.5)12.0 (26.5)17.0 (37.5)17.0 (37.5)22.0 (48.5)22.0 (48.5)

4.2 Operating Pressure Boundaries

Pressure ParameterRated ValueOperating Condition / Allowable Limits
Nominal Pressure (pₙₒₘ)280 bar (4,100 psi)Maximum continuous design pressure at Port A or Port B
Maximum Pressure (pₘₐₓ)350 bar (5,100 psi)Single operating period t≤2.5 ms; total accumulated duration ≤300 hours
Minimum Pressure (p_HD absolute)10 bar (145 psi)Minimum pressure on high-pressure side required to prevent rotary group lift-off
Rate of Pressure Change (RA max)16,000 bar/s (232,000 psi/s)Maximum permissible speed of pressure build-up and reduction
Minimum Low-Pressure Side (p_ND min)2 bar (30 psi) absoluteMinimum required backpressure on low-pressure side to prevent cavitation
Housing Drain Pressure (p_L max)2 bar (30 psi) static / 4 bar (60 psi) peakMaximum permissible case drain pressure at port L or L1 to protect shaft seal

4.3 Hydraulic Fluid Cleanliness & Viscosity Requirements

Fluid PropertySpecified Operational RangeCriteria & System Guidelines
Recommended Hydraulic FluidMineral oil HLP per DIN 51524Suitable for environmentally acceptable fluids (HEES/HEPR) upon seal review
Optimum Viscosity Range (νₒₚₜ)16 to 36 mm²/s (cSt)Yields optimum volumetric efficiency and lowest thermodynamic wear
Permissible Continuous Range10 to 400 mm²/s (cSt)Fluid temperature range: −25 ∘C to +110 ∘C (FKM Seals) measured at drain port L
Cold Start Viscosity Limit≤1,600 mm²/s (cSt)t≤3 min without load (p≤30 bar, n≤1,000 rpm, ϑ≥−25 ∘C)
Short-Term Viscosity Limitνₘᵢₙ =7 to 10 mm²/s (cSt)t≤1 min at p≤0.3×pₙₒₘ and ϑ≤+110 ∘C
Required ISO Cleanliness ClassISO 4406 Class 20/18/15At fluid viscosity <10 mm²/s, minimum cleanliness must reach ISO 19/17/14

Advantages

Field-Proven A10 Swashplate Technology

Utilizes mature A10 rotary group geometry, combining robust swashplate kinematics, exceptional reliability, and proven durability under continuous industrial duties.

Approved for High Rotational Speeds

Engineered for high-speed operation up to 4,900 rpm, delivering responsive auxiliary drive power in compact machinery envelopes.

Exceptionally Low Operating Noise Profile

Precision-contoured swashplate angles, optimized cylinder bore porting, and fluid dampening substantially reduce acoustic emissions across all operating pressure ranges.

High Power-to-Weight Density

Compact ductile iron casing and optimized mass distribution deliver up to 100 kW drive power from an envelope weighing merely 12 kg to 22 kg.

Integral Anti-Cavitation Protection for Fan Drives

Available with an integrated anti-cavitation check valve (Order code 2), safeguarding motor components from overrun vacuum and cavitation damage during sudden diesel engine or hydraulic system shutdowns.

Closed-Circuit Flushing & Cooling Capability

Optional integrated flushing and boost-pressure valve (Order code 7) maintains minimum loop pressure (16 bar retention) and continuous heat dissipation in high-ambient hydrostatic circuits.

Direct 1:1 OEM Bolt-In Interchangeability

Standard SAE-B 2-bolt mounting flange (Ø101.6 mm pilot), standardized shaft splines, and identical port spacing guarantee 100% plug-and-play replacement of Bosch Rexroth A10FM Series 52 motors.

| 6. Cross Reference

6.1 Dimensional & Hydraulic Frame Mapping

Rexroth Original ModelNominal PressureGeometric DisplacementMounting Flange (SAE)Standard Splined ShaftHENGYUHANG Replacement Model
A10FM23.../52280 bar23.5 cm³/revSAE-B 2-bolt (Ø101.6 mm)7/8 in 13T 16/32DP (Shaft R)HYH10FM23
A10FM28.../52280 bar28.5 cm³/revSAE-B 2-bolt (Ø101.6 mm)7/8 in 13T 16/32DP (Shaft R)HYH10FM28
A10FM37.../52280 bar36.7 cm³/revSAE-B 2-bolt (Ø101.6 mm)1 in 15T 16/32DP (Shaft R)HYH10FM37
A10FM45.../52280 bar44.5 cm³/revSAE-B 2-bolt (Ø101.6 mm)1 in 15T 16/32DP (Shaft R)HYH10FM45
A10FM58.../52280 bar58.0 cm³/revSAE-B 2-bolt (Ø101.6 mm)1 1/4 in 14T 12/24DP (Shaft R)HYH10FM58
A10FM63.../52280 bar63.1 cm³/revSAE-B 2-bolt (Ø101.6 mm)1 1/4 in 14T 12/24DP (Shaft R)HYH10FM63

6.2 Port Plate & Valve Configuration Mapping

Port Plate CodePort Orientation & Flange TypeValve IntegrationPrimary Operational Application
10N00Flange Ports ISO 6162-2 (SAE 3/4", M10 metric threads)None (0)Standard medium-pressure open or closed circuit drives
60N00Flange Ports ISO 6162-2 (SAE 3/4", 3/8-16UNC threads)None (0)North American mobile machinery and agricultural implements
16N00 / 66N00Threaded Ports (M27×2 metric or 1 1/16-12UN)None (0)Compact manifold block and threaded tube fitting installations
10N02 / 60N02Flange Ports with Integrated Anti-Cavitation ValveAnti-Cavitation Valve (2)Hydrostatic radiator cooling fan drives with high freewheeling inertia
10N07 / 60N07Flange Ports with Integrated Flushing & Boost ValveFlushing Valve (7, 16 bar)Closed-circuit hydrostatic transmissions requiring continuous heat dissipation

| 7. Brand Replacement

Bosch Rexroth (Primary 1:1 direct drop-in replacement for A10FM Series 52 fixed swashplate motors)

Danfoss / Sauer-Danfoss (Series 45 fixed motors and M46 motor conversions upon engineering review)

Eaton / Vickers (Medium-pressure axial piston motors for auxiliary and fan drive applications)

Parker Hannifin (V12 / V14 / F11 medium-displacement conversions upon engineering review)

Bondioli & Pavesi / Casappa (Fixed axial piston swashplate motors for mobile auxiliary circuits)

| 8. Applications

Hydrostatic Radiator Fan Drives: Powers engine cooling fans in construction machinery, agricultural tractors, and mining trucks; integral anti-cavitation valve prevents overrun cavitation upon engine shutdown.

Vibratory Road Rollers & Compactors: Drives vibration exciter shafts at high rotational speeds with low operating noise and high starting torque.

Agricultural Harvesters & Mowers: Powers header reels, cutter bars, and threshing drives requiring constant speed regulation and reversible operation.

Municipal Street Sweepers & Scrubbers: Drives sweeping brushes, suction turbines, and auxiliary brooms with smooth low-noise fluid power.

Forestry Chipper & Feeder Drives: High-speed swashplate rotary group handles rapid load cycling and shock pressure spikes in timber processing machinery.

Industrial Conveyors & Winch Auxiliaries: Compact SAE-B mounting flange fits directly into planetary gearboxes and conveyor drive sprockets.

| 9. Packaging & Shipping

Packaging LayerSpecification & Protective MaterialSafety Level
Primary ShieldingCorrosion-inhibiting VCI plastic wrap, desiccants, and heavy-duty port thread plugsTotal protection against moisture, humidity, and atmospheric rust
Shock AbsorptionCustom-molded high-density expanded polyethylene (EPE) foam cushioning enclosureAbsorbs multi-axis transit shocks and protects mounting pilots and splines
Outer EnclosureISPM-15 export-compliant non-fumigation engineered solid wooden crateHeavy structural containment for international air, ocean, and multimodal cargo
Logistics OptionsExpress Courier (DHL, FedEx, UPS), International Air Cargo, Ocean LCL/FCL (DDP / CIF)Standard configurations dispatched in 48–72 hours; end-to-end milestone tracking

| 10. Why Choose Hengyuhang?

Direct Factory Precision Manufacturing & CNC Excellence:

Multi-Axis CNC Machining Infrastructure: In-house precision machining centers, swashplate surface grinding lines, and automated honing cells process every motor housing, cylinder block, and swashplate under climate-controlled conditions.

Sub-Micron Micro-Finishing (Ra < 0.2 μm): Critical dynamic friction pairs—including piston slipper pads, swashplate running tracks, and bi-metal valve plate running faces—undergo super-finishing to ensure fluid-film hydro-dynamic equilibrium, minimal internal leakage, and zero micro-scuffing even under high operating temperatures.

Metallurgical Integrity & Thermal Hardening: High-grade nodular ductile iron castings and hardened alloy piston assemblies withstand continuous 280 bar rated duty and 350 bar transient dynamic shock spikes without structural distortion or bore deformation.

100% Full-Cycle Multi-Parameter Factory Inspection & Digital Testing:

End-of-Line Automated Test Bench Validation: Every assembled HYH10FM motor undergoes mandatory, computer-controlled testing simulating real-world fan drive and auxiliary transmission duty cycles.

High-Standard Performance Criteria:

Volumetric Efficiency Verification: Proven >93% under full working pressure, eliminating sluggish auxiliary response.

Pressure Endurance Verification: 100% sustained high-pressure hold at 280 bar nominal and 350 bar peak with zero external seal weepage.

Case Drain Flow Measurement: Real-time monitoring ensures internal bypass flow remains strictly within engineering limits, protecting machine coolers from excess heat generation.

Anti-Cavitation & Low-Noise Verification: Functional validation of anti-cavitation check valve seating and acoustic spectrum testing ensuring smooth, low-noise deceleration.

Full Traceability: Individual test data curves and quality inspection logs are archived per unit serial number before packaging.

Seamless 1:1 OEM Drop-In Interchangeability (True Plug-and-Play):

Exact Dimensional Match: Standard SAE-B 2-bolt mounting flange pilot diameter (Ø101.6 mm / Ø4.0 in), bolt hole spacing (Ø146 mm PCD), and pilot depth correspond 1:1 to original Bosch Rexroth A10FM Series 52 specifications down to the millimeter.

Zero Piping or Chassis Rework: Standard side SAE flange ports (Port Plate 10/60) and threaded ports (Port Plate 16/66) connect directly to existing high-pressure hose assemblies with zero pipe bending or adaptor refitting.

Drive Spline Conformity: Precision ANSI B92.1a involute splines (Shaft Codes R and W) and tapered shafts (Shaft Code C) slide seamlessly into OEM couplings and pump drive hubs without spline binding, backlash vibration, or premature drive hub wear.

Flexible Engineering Customization & Rapid Prototyping:

Fan Drive & Cavitation Protection Options: Factory-configured Port Plate 10/60 with integrated anti-cavitation check valves specifically tuned for heavy-inertia fan drive applications.

Flushing & High-Temperature Options: Integrated low-pressure flushing and boost valves for continuous closed-loop operations in high-ambient tropical environments.

Agile OEM/ODM Solutions: Experienced fluid power engineers provide rapid turnaround for customized port thread standards, specialized shaft extensions, and speed sensor mountings (DST/DSAx), backed by flexible, low-MOQ policies for trial batches.

Robust Supply Chain, Extensive Inventory & Fast Global Dispatch:

Strategic Component Buffering: Continuous safety stocks of fully machined motor housings, finished swashplate rotary groups, precision bearing kits, and valve port plates maintained at the factory warehouse.

Rapid 48–72 Hour Dispatch: Standard configurations and replacement units ship within 48 to 72 hours of order confirmation, eliminating costly mobile machinery downtime.

Global Multimodal Logistics: Established partnerships with tier-1 international freight forwarders, supporting express courier (DHL, FedEx, UPS), air cargo, and door-to-door DDP ocean shipping with full customs handling.

12-Month Comprehensive Warranty & Dedicated Lifetime Technical Support:

Full-Protection Factory Warranty: Comprehensive 12-month warranty covering any manufacturing or material defects with immediate replacement-part dispatch support.

24-Hour Drawing & Model Code Verification: Dedicated technical desk reviews customer machine models, nameplates, port layouts, and dimensional drawings within 24 hours to guarantee zero ordering errors.

Direct Hydraulic Engineering Consultation: Direct technical access to fluid power engineers for circuit troubleshooting, oil contamination analysis, flushing flow sizing, and replacement cross-referencing throughout the machine's entire operational lifecycle.

HENGYUHANG Axial Piston Fixed Motor HYH10FM Series 52

HENGYUHANG Axial Piston Fixed Motor HYH10FM Series 52 is a high-speed, medium-to-high pressure fixed displacement hydraulic motor designed with well-proven A10 swashplate rotary group technology. Engineered for hydrostatic transmissions in both open and closed circuits, the HYH10FM Series 52 features a universal SAE-B 2-bolt mounting flange (ISO 3019-1), ANSI B92.1a involute splined drive shafts, and high-pressure SAE Code 62 or metric/UN threaded working ports. Rated for a nominal continuous operating pressure of 280 bar (4100 psi) and maximum peak pressures up to 350 bar (5100 psi), the HYH10FM delivers high power density, exceptional rotational speed capability up to 4900 rpm, low operating noise, and extended service life. The series is custom-engineered to benchmark OEM specifications of the Bosch Rexroth A10FM Series 52 fixed motor (sizes 23 to 63 cm³/rev), serving as an interchangeable replacement for hydrostatic radiator cooling fan drives, agricultural machinery, municipal sweepers, and auxiliary mobile equipment.

Technical Benchmark Notice: All performance values, physical dimensions, and interface standards presented on this page are benchmarked against original manufacturer technical specifications (Bosch Rexroth RE 91172). Dimensional alignment, port threads, and performance ratings for custom replacement units are verified against customer application requirements and factory test certificates prior to dispatch.

Key Technical & Operational Features

  • Field-Proven A10 Swashplate Technology: Built on the mature A10 rotary unit architecture featuring high-precision piston-slipper assemblies and bi-metal valve plates, ensuring excellent volumetric efficiency, high reliability, and low operational friction.

  • Approved for High Rotational Speeds: Optimized swashplate angle and low-mass rotating components permit high continuous operating speeds up to 4900 rpm (size 23), 4700 rpm (size 28), and 4000 rpm (size 45), perfectly suited for high-speed blower and fan applications.

  • Integral Anti-Cavitation Valve (Option Code 2): Available with an integrated anti-cavitation check valve built into the port plate. When the system shuts down, the valve feeds hydraulic fluid from the return line to prevent motor cavitation caused by heavy fan impeller inertia during coast-down.

  • Compact Standardized SAE-B Mounting: Standardized ISO 3019-1 (SAE J744) 2-bolt mounting flange with Ø101.6 mm pilot diameter and 146 mm bolt hole spacing facilitates straightforward retrofit into existing machine frames.

  • Flexible Porting Configurations: Same-side lateral working ports available in 3/4" SAE Code 62 flange (ISO 6162-2 with metric or UNC mounting threads) or threaded DIN 3852 / ISO 11926 ports for streamlined hydraulic plumbing.

  • Integrated Closed-Circuit Flushing Valve (Option Code 7): Optional integrated flushing and boost-pressure valve (fixed 16 bar cracking pressure) continuously discharges warm fluid into the casing for circuit cooling in closed-loop systems.

  • Electronic Speed Sensor Integration: Factory-machined housing port (Option Code W) allows seamless installation of DSA or DST digital Hall-effect speed sensors for precision closed-loop fan speed and motor speed monitoring.

  • Low Acoustic Emission: Rigid cast housing and fluid pre-compression damping reduce pressure pulsation and operational noise levels across the entire working speed range.

Primary Application Fields

The HENGYUHANG HYH10FM Series 52 fixed displacement motor is widely utilized across mobile machinery, commercial vehicles, and agricultural equipment requiring compact high-speed drives:

Engine Cooling Fan Drives: Hydrostatic radiator fan drives on heavy trucks, transit buses, wheel loaders, and excavators (utilizing Code 2 integral anti-cavitation valve to safeguard against impeller inertia shutdown).

Agricultural Machinery: Combine harvester cleaning fan drives, pneumatic seed drill blower fans, fertilizer spreader disc rotators, and forage harvester header drives.

Municipal & Road Maintenance: Road sweeper suction turbine fans, broom rotation drives, salt/sand spreader spinner motors, and snow blower auger auxiliary drives.

Forestry & Industrial Equipment: Hydraulic oil cooler fan drives, mobile generator hydraulic drives, wood chipper feeder rollers, and industrial conveyor auxiliary rotators.

Technical Performance Matrix (OEM Benchmark Reference)

Technical Parameter / Frame SizeSize 23Size 28Size 37Size 45Size 58Size 63
Geometric Displacement Vg max [cm³/rev]23.528.536.744.558.063.1
Geometric Displacement Vg max [cu.in/rev]1.431.732.242.713.533.84
Nominal Operating Pressure pnom [bar / psi]280 / 4100280 / 4100280 / 4100280 / 4100280 / 4100280 / 4100
Maximum Peak Pressure pmax [bar / psi]350 / 5100350 / 5100350 / 5100350 / 5100350 / 5100350 / 5100
Maximum Rotational Speed nnom (at Vg max) [rpm]490047004200400036003400
Maximum Inlet Flow qV max (at nnom) [L/min / gpm]115 / 30.4134 / 35.4154 / 40.7178 / 47.0209 / 55.2215 / 56.8
Maximum Drive Power Pmax (at nnom, 280 bar) [kW / HP]53.6 / 7162.5 / 8371.8 / 9583.1 / 11197.4 / 130100.1 / 133
Output Torque Mmax (at pN = 280 bar) [Nm / lb-ft]105 / 77.4127 / 93.7163 / 120198 / 146258 / 190281 / 207
Actual Starting Torque (approx. at n=0, 280 bar) [Nm / lb-ft]75 / 55.3105 / 77.5125 / 92.2170 / 125205 / 151230 / 169
Rotary Stiffness of Drive Shaft R [Nm/rad]284782847846859468598059080590
Moment of Inertia of Rotary Group JTW [kg·m²]0.00170.00170.00330.00330.00560.0056
Maximum Angular Acceleration α [rad/s²]550055004000400033003300
Case Fluid Volume V [L / gal]0.6 / 0.160.6 / 0.160.7 / 0.180.7 / 0.180.8 / 0.210.8 / 0.21
Dry Weight (Approximate) [kg / lbs]12 / 26.512 / 26.517 / 37.517 / 37.522 / 48.522 / 48.5

* Technical values referenced from OEM datasheet RE 91172 for optimal mineral oil viscosity range νopt = 16 to 36 mm²/s. Theoretical values excluding mechanical and volumetric tolerances. Note: Micro displacement sizes 10, 11, 14, 16, and 18 cm³/rev are available upon request in the plug-in A10FE series configuration.

Mechanical Installation Interface Specifications

Part 1: Standard SAE-B 2-bolt mounting flange dimensions (ISO 3019-1), centering pilot diameter, bolt hole pitch, and ANSI B92.1a involute splined / conical drive shafts.

Frame Size (NG)Flange Standard & CodeCentering Pilot Ø (ISO 3019-1)Bolt Hole Pitch & PatternPrimary Splined Shaft (ANSI B92.1a)Secondary Splined / Conical Shaft
HYH10FM023 / 028ISO 3019-1 (SAE-B 2-bolt, Code C)Ø101.6 mm (0 / -0.054 mm)Pitch 146 mm / 2x Ø14.3 mmCode R: 7/8 in 13T 16/32 DP (22-4(B))Code C: Conical keyed shaft (22-3(B))
HYH10FM037 / 045ISO 3019-1 (SAE-B 2-bolt, Code C)Ø101.6 mm (0 / -0.054 mm)Pitch 146 mm / 2x Ø14.3 mmCode R: 1 in 15T 16/32 DP (25-4(B-B))Code W: 7/8 in 13T / Code C: Conical shaft
HYH10FM058 / 063ISO 3019-1 (SAE-B 2-bolt, Code C)Ø101.6 mm (0 / -0.054 mm)Pitch 146 mm / 2x Ø14.3 mmCode R: 1 1/4 in 14T 12/24 DP (32-4(C))Code W: 1 in 15T / Code C: Conical shaft

Fluid Connection & Port Configuration Specifications

Part 2: Hydraulic fluid connections across working lines A/B (SAE Code 62 or metric/UN thread), case drain ports L/L1, and valve interface options.

Frame Size (NG)Working Ports A & B (SAE Metric 10N00)Working Ports A & B (SAE UNC 60N00)Threaded Ports A & B (Metric 16 / UN 66)Case Drain Ports L & L1 (ISO 11926)
HYH10FM023 / 0283/4 in SAE Code 62 (M10×1.5, 17 deep)3/4 in SAE Code 62 (3/8-16 UNC, 21 deep)M27×2 (DIN 3852) / 1 1/16-12 UN (ISO 11926)3/4-16 UNF-2B (15 mm deep, max 4 bar)
HYH10FM037 / 0453/4 in SAE Code 62 (M10×1.5, 17 deep)3/4 in SAE Code 62 (3/8-16 UNC, 21 deep)M27×2 (DIN 3852) / 1 1/16-12 UN (ISO 11926)7/8-14 UNF-2B (17 mm deep, max 4 bar)
HYH10FM058 / 0633/4 in SAE Code 62 (M10×1.5, 17 deep)3/4 in SAE Code 62 (3/8-16 UNC, 21 deep)M27×2 (DIN 3852) / 1 1/16-12 UN (ISO 11926)7/8-14 UNF-2B (17 mm deep, max 4 bar)

Integrated Valve Configurations

Valve Option CodeValve Description & ExecutionFunctional Characteristics & Circuit Application
Code 0Standard Port Plate (Without Valve)Standard open- and closed-circuit bi-directional operation without internal valves. Intended for systems with external relief and counterbalance valves.
Code 2Integrated Anti-Cavitation Valve (Fan Drive)Specifically engineered for heavy-duty fan drives. Upon diesel engine shutdown or abrupt valve closure, the anti-cavitation check valve automatically draws fluid from the low-pressure/return line into the motor inlet, preventing severe cavitation and cylinder barrel lift-off while the fan impeller inertia coasts down to a stop. Pre-configured for either Clockwise (R) or Counter-clockwise (L) rotation. External dimensions remain identical to the standard motor.
Code 7Integrated Flushing & Boost-Pressure ValveUsed in closed hydrostatic circuits for heat dissipation and safeguarding minimum boost pressure. A flushing spool directs warm low-pressure fluid across an orifice into the motor casing to be returned to tank, replaced by cooled fluid from the charge pump. Standard flushing flow is 5.5 L/min with fixed 16 bar cracking pressure.
Sensor Option (W / C / K / E)Electronic Speed Sensor Preparation / MountedMachined housing port allows non-contact magnetic speed sensing off the rotary group piston count. Code W is prepared with plug; Code C includes DSA1 sensor (speed & direction); Code K includes DSA2 sensor (quadrature phase-shifted); Code E includes DST speed sensor.

HENGYUHANG HYH10FM Series 52 Ordering Code Structure

Pos.Code SegmentAvailable OptionsDescription & Engineering Specifications
01Axial Piston UnitHYH10FSwashplate design, fixed displacement, nominal pressure 280 bar (4100 psi), peak 350 bar (5100 psi)
02Operating ModeMMotor, open and closed hydrostatic circuits
03Nominal Size (NG)023 / 028
037 / 045
058 / 063
Displacement sizes: 23.5, 28.5, 36.7, 44.5, 58.0, 63.1 cm³/rev
04Series Index52Series 5, Index 2
05Direction of RotationR
L
W
Clockwise rotation (viewed on drive shaft, required with anti-cavitation valve)
Counter-clockwise rotation (required with anti-cavitation valve)
Alternating / reversible rotation (standard motor without anti-cavitation valve)
06Sealing MaterialVFKM (Fluorocarbon rubber / Viton seals, high-temperature rating up to 110 °C)
07Drive Shaft CodeR
W
C
Splined shaft ANSI B92.1a (standard high torque: 7/8" on 23-28, 1" on 37-45, 1 1/4" on 58-63)
Splined shaft ANSI B92.1a (reduced diameter: 7/8" on 37-45, 1" on 58-63)
Conical keyed shaft with threaded spigot (taper 125:1000)
08Mounting FlangeCBased on ISO 3019-1 (SAE-B 2-hole, Ø101.6 mm pilot, 146 mm hole pitch)
09Working Ports A & B10N00
60N00
16N00
66N00
3/4" SAE Code 62 flange ports lateral same side, metric M10 fastening threads
3/4" SAE Code 62 flange ports lateral same side, 3/8-16 UNC fastening threads
Threaded ports DIN 3852-1, metric M27×2 lateral same side
Threaded ports ISO 11926, 1 1/16-12 UN lateral same side
10Integrated Valves0
2
7
Without internal valve (standard)
Integrated anti-cavitation valve (configured for fan drives)
Integrated flushing and boost-pressure valve (closed circuits, fixed 16 bar)
11Speed SensingOmitted
W
C / K / E
Without speed sensor
Prepared for electronic speed sensor (DST or DSAx)
DSA1 speed sensor mounted (C), DSA2 mounted (K), or DST sensor mounted (E)

Example Standard Order Codes: HYH10FM45/52W-VRC10N000 (Size 45 cm³, Series 52, Bi-directional, Viton Seals, 1" Splined Shaft, SAE-B Flange, 3/4" Metric Flange Ports, Standard without Valve) or HYH10FM28/52R-VRC10N002 (Size 28 cm³, Clockwise, with Integrated Anti-Cavitation Valve for Cooling Fan Drives).

Direct Interchangeability & OEM Cross-Reference Matrix

HENGYUHANG HYH10FM Series 52 fixed motors are engineered to match OEM Bosch Rexroth A10FM Series 52 mounting flanges, drive shafts, and port locations. Key dimensional and interface specifications should be cross-verified against OEM reference drawings for exact fitment:

OEM Rexroth Model CodeHENGYUHANG Replacement CodeDisplacement & FlangeShaft & PortsValve ConfigurationCompatibility Status
A10FM23/52W-VRC10N000HYH10FM23/52W-VRC10N00023.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM28/52R-VRC10N002HYH10FM28/52R-VRC10N00228.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM28/52W-VRC60N000HYH10FM28/52W-VRC60N00028.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" UNCWithout ValveDirect Interchangeable (Verify Fit)
A10FM37/52W-VRC10N000HYH10FM37/52W-VRC10N00036.7 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM45/52R-VRC10N002HYH10FM45/52R-VRC10N00244.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM45/52W-VRC10N000HYH10FM45/52W-VRC10N00044.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM45/52W-VRC10N007HYH10FM45/52W-VRC10N00744.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricFlushing & Boost (16 bar)Direct Interchangeable (Verify Fit)
A10FM58/52W-VRC10N000HYH10FM58/52W-VRC10N00058.0 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM63/52R-VRC10N002HYH10FM63/52R-VRC10N00263.1 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM63/52W-VRC10N000HYH10FM63/52W-VRC10N00063.1 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)

Hydraulic Commissioning & Installation Guidelines

1. Initial Priming & Casing Filling: Before commissioning, the motor casing must be filled with clean, filtered hydraulic oil through the highest positioned drain port (L or L1) and completely deaerated. Running the motor dry or partially primed will cause rapid wear on the piston shoes and swashplate bearing surface.

2. Housing Drain Line Routing: Drain line L or L1 must be piped directly to the hydraulic reservoir without restrictions or check valves. The static casing pressure must not exceed 2 bar absolute (continuous) or 4 bar absolute (transient peak). Excessive casing pressure damages the FKM shaft seal.

3. Anti-Cavitation Valve Operation (Fan Drives): When utilizing Option Code 2, verify that the specified rotation direction (R for Clockwise or L for Counter-clockwise) matches the system hydraulic feed. Ensure that the low-pressure return line has a minimum static pressure of pND min ≥ 2 bar to provide sufficient makeup oil during fan coast-down.

4. Fluid Cleanliness Standard: Maintain fluid cleanliness class according to ISO 4406 at 20/18/15 or better (maintain 19/17/14 if fluid temperature exceeds 80 °C or viscosity drops below 10 mm²/s). Use pressure or return-line filters with β10 ≥ 100.

5. Drive Shaft Alignment & Radial Loading: When driving cooling fans via belts or direct pulleys, ensure that external radial forces (Fq) do not exceed the permissible limits (1200 N for sizes 23–28; 1500 N for sizes 37–45; 1700 N for sizes 58–63 at shaft center).

Data Verification & Technical Notes

Reference Benchmark Datasheet: Bosch Rexroth AG Technical Datasheet RE 91172 (Edition: 2024-11-18), Pages 1–39 (Axial Piston Fixed Motor A10FM / A10FE Series 52).

Quality Inspection & Performance Testing: Every HENGYUHANG HYH10FM motor is dynamically tested on automated test benches for volumetric efficiency, starting torque, casing leakage, and high-speed stability under 280 bar nominal and 350 bar peak pressure prior to dispatch.

Custom Engineering & Application Verification: Key mounting dimensions, flange pilots, drive shaft splines, port thread standards, and valve settings should be cross-verified against OEM reference drawings and specific machine requirements prior to final selection.

SEO Meta Title: HYH10FM Series 52 Axial Piston Fixed Motor | Rexroth A10FM Replacement | Hengyuhang

SEO Meta Keywords: HYH10FM, A10FM series 52, axial piston fixed motor, swashplate motor, A10FM23, A10FM28, A10FM37, A10FM45, A10FM58, A10FM63, Rexroth A10FM replacement, hydraulic fan drive motor, anti-cavitation motor, Hengyuhang hydraulic

SEO Meta Description: HENGYUHANG HYH10FM Series 52 axial piston fixed displacement hydraulic motors. Benchmarked replacement for Bosch Rexroth A10FM Series 52 (sizes 23 to 63). Nominal pressure 280 bar, peak 350 bar, swashplate design, SAE 2-bolt flange, integral anti-cavitation valve for cooling fan drives.

Technical Performance Matrix (OEM Benchmark Reference)

Technical Parameter / Frame SizeSize 23Size 28Size 37Size 45Size 58Size 63
Geometric Displacement Vg max [cm³/rev]23.528.536.744.558.063.1
Geometric Displacement Vg max [cu.in/rev]1.431.732.242.713.533.84
Nominal Operating Pressure pnom [bar / psi]280 / 4100280 / 4100280 / 4100280 / 4100280 / 4100280 / 4100
Maximum Peak Pressure pmax [bar / psi]350 / 5100350 / 5100350 / 5100350 / 5100350 / 5100350 / 5100
Maximum Rotational Speed nnom (at Vg max) [rpm]490047004200400036003400
Maximum Inlet Flow qV max (at nnom) [L/min / gpm]115 / 30.4134 / 35.4154 / 40.7178 / 47.0209 / 55.2215 / 56.8
Maximum Drive Power Pmax (at nnom, 280 bar) [kW / HP]53.6 / 7162.5 / 8371.8 / 9583.1 / 11197.4 / 130100.1 / 133
Output Torque Mmax (at pN = 280 bar) [Nm / lb-ft]105 / 77.4127 / 93.7163 / 120198 / 146258 / 190281 / 207
Actual Starting Torque (approx. at n=0, 280 bar) [Nm / lb-ft]75 / 55.3105 / 77.5125 / 92.2170 / 125205 / 151230 / 169
Rotary Stiffness of Drive Shaft R [Nm/rad]284782847846859468598059080590
Moment of Inertia of Rotary Group JTW [kg·m²]0.00170.00170.00330.00330.00560.0056
Maximum Angular Acceleration α [rad/s²]550055004000400033003300
Case Fluid Volume V [L / gal]0.6 / 0.160.6 / 0.160.7 / 0.180.7 / 0.180.8 / 0.210.8 / 0.21
Dry Weight (Approximate) [kg / lbs]12 / 26.512 / 26.517 / 37.517 / 37.522 / 48.522 / 48.5

* Technical values referenced from OEM datasheet RE 91172 for optimal mineral oil viscosity range νopt = 16 to 36 mm²/s. Theoretical values excluding mechanical and volumetric tolerances. Note: Micro displacement sizes 10, 11, 14, 16, and 18 cm³/rev are available upon request in the plug-in A10FE series configuration.

HENGYUHANG HYH10FM Series 52 Ordering Code Structure

Pos.Code SegmentAvailable OptionsDescription & Engineering Specifications
01Axial Piston UnitHYH10FSwashplate design, fixed displacement, nominal pressure 280 bar (4100 psi), peak 350 bar (5100 psi)
02Operating ModeMMotor, open and closed hydrostatic circuits
03Nominal Size (NG)023 / 028
037 / 045
058 / 063
Displacement sizes: 23.5, 28.5, 36.7, 44.5, 58.0, 63.1 cm³/rev
04Series Index52Series 5, Index 2
05Direction of RotationR
L
W
Clockwise rotation (viewed on drive shaft, required with anti-cavitation valve)
Counter-clockwise rotation (required with anti-cavitation valve)
Alternating / reversible rotation (standard motor without anti-cavitation valve)
06Sealing MaterialVFKM (Fluorocarbon rubber / Viton seals, high-temperature rating up to 110 °C)
07Drive Shaft CodeR
W
C
Splined shaft ANSI B92.1a (standard high torque: 7/8" on 23-28, 1" on 37-45, 1 1/4" on 58-63)
Splined shaft ANSI B92.1a (reduced diameter: 7/8" on 37-45, 1" on 58-63)
Conical keyed shaft with threaded spigot (taper 125:1000)
08Mounting FlangeCBased on ISO 3019-1 (SAE-B 2-hole, Ø101.6 mm pilot, 146 mm hole pitch)
09Working Ports A & B10N00
60N00
16N00
66N00
3/4" SAE Code 62 flange ports lateral same side, metric M10 fastening threads
3/4" SAE Code 62 flange ports lateral same side, 3/8-16 UNC fastening threads
Threaded ports DIN 3852-1, metric M27×2 lateral same side
Threaded ports ISO 11926, 1 1/16-12 UN lateral same side
10Integrated Valves0
2
7
Without internal valve (standard)
Integrated anti-cavitation valve (configured for fan drives)
Integrated flushing and boost-pressure valve (closed circuits, fixed 16 bar)
11Speed SensingOmitted
W
C / K / E
Without speed sensor
Prepared for electronic speed sensor (DST or DSAx)
DSA1 speed sensor mounted (C), DSA2 mounted (K), or DST sensor mounted (E)

Example Standard Order Codes: HYH10FM45/52W-VRC10N000 (Size 45 cm³, Series 52, Bi-directional, Viton Seals, 1" Splined Shaft, SAE-B Flange, 3/4" Metric Flange Ports, Standard without Valve) or HYH10FM28/52R-VRC10N002 (Size 28 cm³, Clockwise, with Integrated Anti-Cavitation Valve for Cooling Fan Drives).

Direct Interchangeability & OEM Cross-Reference Matrix

HENGYUHANG HYH10FM Series 52 fixed motors are engineered to match OEM Bosch Rexroth A10FM Series 52 mounting flanges, drive shafts, and port locations. Key dimensional and interface specifications should be cross-verified against OEM reference drawings for exact fitment:

OEM Rexroth Model CodeHENGYUHANG Replacement CodeDisplacement & FlangeShaft & PortsValve ConfigurationCompatibility Status
A10FM23/52W-VRC10N000HYH10FM23/52W-VRC10N00023.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM28/52R-VRC10N002HYH10FM28/52R-VRC10N00228.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM28/52W-VRC60N000HYH10FM28/52W-VRC60N00028.5 cm³, SAE-B 2-bolt7/8" 13T, SAE 3/4" UNCWithout ValveDirect Interchangeable (Verify Fit)
A10FM37/52W-VRC10N000HYH10FM37/52W-VRC10N00036.7 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM45/52R-VRC10N002HYH10FM45/52R-VRC10N00244.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM45/52W-VRC10N000HYH10FM45/52W-VRC10N00044.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM45/52W-VRC10N007HYH10FM45/52W-VRC10N00744.5 cm³, SAE-B 2-bolt1" 15T, SAE 3/4" MetricFlushing & Boost (16 bar)Direct Interchangeable (Verify Fit)
A10FM58/52W-VRC10N000HYH10FM58/52W-VRC10N00058.0 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)
A10FM63/52R-VRC10N002HYH10FM63/52R-VRC10N00263.1 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricAnti-Cavitation (Clockwise)Direct Interchangeable (Verify Fit)
A10FM63/52W-VRC10N000HYH10FM63/52W-VRC10N00063.1 cm³, SAE-B 2-bolt1 1/4" 14T, SAE 3/4" MetricWithout ValveDirect Interchangeable (Verify Fit)