HENGYUHANG HYHT90 Series axial piston variable displacement pumps deliver heavy-duty hydrostatic power for closed-circuit mobile transmissions, featuring an optimized 9-piston rotating group, cradle swashplate design, and integrated charge pump engineered for continuous 350 to 420 bar operation with exceptional volumetric efficiency and compact installation flexibility.
| Applications
Engineered specifically for extreme-duty mobile machinery, the HYHT90 Series serves as the primary hydrostatic propulsion and drive pump for 6–18 m³ transit concrete mixer truck drums, road compaction rollers, agricultural combine harvesters, and heavy-duty closed-loop industrial winches operating under severe shock and continuous reversal cycles.
| Key Technical Specifications
Product Model: HENGYUHANG HYHT90 Series (HYHT90R / HYHT90L)
Brand Replacement: Danfoss / Sauer-Danfoss T90 Series (OEM or tailored as requested)
Displacement: 55 cm³/rev [3.36 in³/rev], 75 cm³/rev [4.58 in³/rev], 100 cm³/rev [6.10 in³/rev]
Rotation Direction: Clockwise (Right Hand - CW) / Counterclockwise (Left Hand - CCW)
Speed Range: 400–500 rpm minimum, 3,000–3,500 rpm rated, up to 3,700 rpm maximum
Peak Pressure: 350–420 bar [5,076–6,000 psi] continuous / 420–480 bar [6,092–7,000 psi] peak
| Overview of HENGYUHANG HYHT90 Series Hydraulic Pumps
The HENGYUHANG HYHT90 Series represents a specialized, high-power-density family of variable displacement axial piston pumps designed for closed-circuit hydrostatic transmissions. Built upon proven heavy-duty hydrostatic architecture and optimized specifically for high-shock applications such as transit concrete mixers, road rollers, and agricultural vehicles, the HYHT90 delivers exceptional reliability, high mechanical efficiency, and low operating noise.
The pump utilizes a parallel axial piston and slipper retaining mechanism operating against a hardened tiltable cradle swashplate. Tilting the swashplate changes the axial stroke of the 9 pistons, providing smooth, infinitely variable output flow from zero to maximum in both forward and reverse directions. Reversing the swashplate tilt angle smoothly reverses oil flow through the main system loop without requiring external directional control valves.
An integral high-efficiency gerotor charge pump supplies essential replenishing oil to compensate for internal closed-loop leakage, maintains positive suction pressure at the main piston group, feeds cooling flow through external heat exchangers, and delivers steady pilot control fluid to the dual-acting hydraulic servo cylinders. The HYHT90 offers extensive control versatility—including robust Manual Displacement Control (MDC) with neutral start switches and friction detents, 3-position Electric Solenoid Control (FNR), and High Current Electric Displacement Control (HCEDC)—ensuring seamless integration into mechanical cable, linkage, or advanced CAN-bus electronic vehicle architectures.
| Dimension of HENGYUHANG HYHT90 Series Hydraulic Pumps


| Interface Technical Specifications
| Interface Element | HYHT90-055 Frame | HYHT90-075 Frame | HYHT90-100 Frame |
|---|---|---|---|
| Mounting Flange (ISO 3019-1 / SAE J744) | SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.34 mm bolt holes on ∅161.9 mm B.C.) | SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.34 mm bolt holes on ∅161.9 mm B.C.) | SAE C 4-bolt (∅127.0 mm pilot [∅5.00 in], 14.34 mm bolt holes on ∅161.9 mm B.C.) |
| Main Working Ports A & B | 1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 24 mm thread depth) | 1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 24 mm thread depth) | 1.00 in SAE J518 Code 62 split flange (M12×1.75 metric or 7/16-14 UNC-2B, min 24 mm thread depth) |
| Charge Pump Inlet Port (S) | 1-5/16-12 UN-2B straight thread O-ring boss | 1-5/16-12 UN-2B straight thread O-ring boss | 1-5/8-12 UN-2B straight thread O-ring boss |
| Case Drain Ports (L1, L2) | 1-1/16-12 UN-2B straight thread O-ring boss | 1-1/16-12 UN-2B straight thread O-ring boss | 1-1/16-12 UN-2B straight thread O-ring boss |
| System Pressure Gauge Ports (M1, M2) | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss |
| Charge Pressure Gauge Port (M3) | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss |
| Servo Gauge Ports (M4, M5) | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss | 9/16-18 UNF-2B O-ring boss |
| Auxiliary Rear Through-Drive Pads | SAE A (9T), SAE B (13T), SAE B-B (15T), SAE C (14T) | SAE A (9T), SAE B (13T), SAE B-B (15T), SAE C (14T) | SAE A (9T), SAE B (13T), SAE B-B (15T), SAE C (14T) |
| Installation Specifications
| Fluid Power Calculation Equations
Output Flow: Q = (Vg · n · ηv) / 1000 [l/min] (Q = (Vg · n · ηv) / 231 [US gal/min])
Input Torque: M = (Vg · Δp) / (20 · π · ηm) [N·m] (M = (Vg · Δp) / (2 · π · ηm) [lbf·in])
Input Power: P = (M · n · π) / 30,000 = (Q · Δp) / (600 · ηt) [kW] (P = (M · n · π) / 198,000 = (Q · Δp) / (1714 · ηt) [hp])
Where:
Vg: Displacement per revolution (cm³/rev or in³/rev)
Δp: Differential system pressure, pO − pi (bar or psi)
n: Shaft rotational speed (min⁻¹ / rpm)
ηv: Volumetric efficiency (≥0.94)
ηm: Mechanical efficiency (≥0.92)
ηt: Overall efficiency, ηv · ηm
| Port Identification & Thread Matrix
| Port Symbol | Functional Description | Port Type & Dimension (ISO / SAE Standard) | Sealing Mechanism |
|---|---|---|---|
| A / B | Main High-Pressure Closed Loop Ports | 1.00 in SAE J518 Code 62 / ISO 6162-2 Split Flange (M12×1.75 or 7/16-14) | O-Ring face seal (6000 psi rating) |
| S | Charge Pump Suction Inlet | 1-5/16-12 UN-2B (055/075) / 1-5/8-12 UN-2B (100) per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| L1, L2 | Case Drain Outlets (Top / Side / Bottom) | 1-1/16-12 UN-2B straight thread per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| M1, M2 | High Pressure Gauge Ports (Loop A & B) | 9/16-18 UNF-2B straight thread per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| M3 | Charge Pressure Gauge Port | 9/16-18 UNF-2B straight thread per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| M4, M5 | Servo Piston Cylinder Pressure Ports | 9/16-18 UNF-2B straight thread per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| M14 | Case Pressure Gauge Port (HCEDC option) | 7/16-20 UNF-2B straight thread per ISO 11926-1 | SAE Straight Thread O-Ring Boss (ORB) |
| Drive Shaft & Overhung Load Ratings
The overhung load moment induced by tandem-mounted auxiliary pumps or extreme machine shock accelerations is calculated via:
MR = g · GR · ∑(Wi · Li) [N·m] (Rated Vibratory Load Moment)
MS = g · GS · ∑(Wi · Li) [N·m] (Maximum Shock Acceleration Load Moment)
Where Wi is component mass (kg), Li is distance from mounting flange to center of gravity (m), g = 9.81 m/s², and GR / GS are dynamic acceleration factors (GR = 6 to 8, GS = 10 to 20 for mixer trucks and compactors).
| Frame Size | Rated Moment MR (N·m [lbf·in]) | Max Shock Moment MS (N·m [lbf·in]) | Available Input Shaft Splines | Max Input Torque (N·m [lbf·ft]) |
|---|---|---|---|---|
| HYHT90-055 | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] | C6: 21T 16/32 DP; D9: 21T 16/32 with M10; S1: 14T 12/24 DP | C6: 1,287 N·m [949 lbf·ft]; S1: 832 N·m [613 lbf·ft] |
| HYHT90-075 | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] | C7: 23T 16/32 DP; D7: 23T with M10; DC: 23T Mixer Flange; S1: 14T 12/24 | C7: 1,625 N·m [1,218 lbf·ft]; C6: 1,214 N·m [895 lbf·ft] |
| HYHT90-100 | 1,580 N·m [14,000 lbf·in] | 5,650 N·m [50,000 lbf·in] | C7: 23T 16/32 DP; D7: 23T with M10; DC: 23T Mixer Flange; S1: 14T 12/24 | C7: 1,822 N·m [1,344 lbf·ft]; S1: 974 N·m [718 lbf·ft] |
| Parameter Metric | Unit | HYHT90-055 Frame | HYHT90-075 Frame | HYHT90-100 Frame |
|---|---|---|---|---|
| Geometric Displacement | cm³/rev [in³/rev] | 55.0 [3.36] | 75.0 [4.58] | 100.0 [6.10] |
| Theoretical Flow @ Rated Speed | l/min [US gpm] | 193 [51] (@ 3500 rpm) | 270 [71] (@ 3600 rpm) | 300 [79] (@ 3000 rpm) |
| Theoretical Flow @ 1000 rpm | l/min [US gpm] | 55.0 [14.5] | 75.0 [19.8] | 100.0 [26.4] |
| Theoretical Torque @ Max Displacement | N·m/bar [lbf·in/1000 psi] | 0.88 [530] | 1.19 [730] | 1.59 [970] |
| Rotating Assembly Mass Moment of Inertia | kg·m² [slug·ft²] | 0.0065 [0.0048] | 0.0100 [0.0074] | 0.0171 [0.0126] |
| Dry Weight (with Manual Control MA) | kg [lb] | 40 [88] | 49 [108] | 68 [150] |
| Minimum Operating Speed | min⁻¹ (rpm) | 400–500 | 400–500 | 400–500 |
| Continuous Rated Speed | min⁻¹ (rpm) | 3,500–3,900 | 3,150–3,600 | 3,000–3,300 |
| Maximum Intermittent Speed | min⁻¹ (rpm) | 3,700–4,250 | 3,350–3,950 | 3,200–3,650 |
| Continuous Operating Working Pressure | bar [psi] | 350–420 [5,076–6,000] | 350–420 [5,076–6,000] | 350–420 [5,076–6,000] |
| Maximum Peak System Pressure | bar [psi] | 420–480 [6,092–7,000] | 420–480 [6,092–7,000] | 420–480 [6,092–7,000] |
| Minimum Low-Pressure Loop Backpressure | bar [psi] | 10 [150] | 10 [150] | 10 [150] |
| Charge Pump Relief Valve Pressure | bar [psi] | 20–24 [290–350] nominal | 20–24 [290–350] nominal | 20–24 [290–350] nominal |
| Charge Pump Suction Inlet Pressure (Continuous) | bar abs. [in Hg vac.] | ≥0.7 bar abs. [9 in Hg] | ≥0.7 bar abs. [9 in Hg] | ≥0.7 bar abs. [9 in Hg] |
| Case Drain Pressure (Rated / Cold Start Peak) | bar [psi] | 3.0 [40–44] continuous / 5.0 [75] peak | 3.0 [40–44] continuous / 5.0 [75] peak | 3.0 [40–44] continuous / 5.0 [75] peak |
| Operating Characteristic | Operational Standard & Limitation Requirement | Technical Field Note |
|---|---|---|
| Recommended Operating Viscosity Range | 12 to 80 mm²/s (cSt) [66 to 370 SUS] | Optimum balance of volumetric film thickness and fluid friction |
| Absolute Minimum Fluid Viscosity | 7 mm²/s (cSt) [49 SUS] | Minimum intermittent rating at elevated operating temperatures |
| Cold Start Maximum Viscosity | 1,600 mm²/s (cSt) [7,500 SUS] | Cold start at low rpm (<1000 rpm) and low pressure (<50 bar) |
| Operating Temperature Range | −40 ∘C to 104 ∘C [−40 ∘F to 220 ∘F] | Continuous rating; intermittent short-term ceiling is 115 ∘C [240 ∘F] |
| Recommended Fluid Cleanliness Class | ISO 4406 Class 22/18/13 (or cleaner) | Essential for long-term valve plate and slipper hydro-bearing life |
| Filtration Beta Ratio (β) Requirement | Charge filtration: β₁₅₋₂₀ ≥75 (β₁₀ ≥10); Suction: β₃₅₋₄₅ ≥75 | Suction screen mesh size: 100 to 125 μm |
Engineered with a high-density 9-piston rotating assembly that minimizes hydraulic pressure pulsation and fluid-borne vibration by up to 25% compared to 7-piston designs. The high-strength ductile iron cylinder barrel is mated with an alloy-bonded bimetallic valve plate (CP15 design with +0.5 ∘ timing advance), ensuring optimal hydrodynamic oil film formation, low boundary friction, and superior galling resistance under extreme loads.
Specifically redesigned to minimize overall length and mass compared to generic industrial pumps, the HYHT90 features shortened endcaps and concentrated porting. This ultra-compact profile delivers exceptional power-to-weight density, freeing critical chassis space for mixer truck water tanks, chute mechanisms, engine cooling stacks, and auxiliary tractor components.
Equipped with integrated gerotor charge pump options (14, 17, 20, and 26 cm³/rev) delivering substantial replenishing flow even at engine idle speeds (400–500 rpm). This guarantees adequate low-pressure loop replenishment, prevents cavitational erosion during rapid vehicle braking, and provides steady pilot pressure to servo actuators.
Integrates dual multi-function valves incorporating high-pressure relief valves and optional sequenced Pressure Limiting (PL) cut-off spools. When preset working pressure is reached, the PL system instantly de-strokes the swashplate within milliseconds, preventing excessive fluid heating and energy waste associated with full-flow relief valve dumping.
The driveshaft is supported by premium heavy-duty tapered roller bearings engineered to absorb high external overhung moments and radial loads from direct cardan shaft PTO couplings. The hardened alloy swashplate swivels on steel-backed PTFE-lined polymer cradle bushings, providing frictionless angular responsiveness and exceptional fatigue resistance.
Offers multiple control architectures including Manual Displacement Control (MDC) with adjustable friction lock or spring-return-to-neutral, neutral start safety switches (NSS) to prevent engine ignition while in gear, 3-position electric solenoid control (FNR), and proportional High Current Electric Displacement Control (HCEDC) with IP69K sealed Deutsch connectors.
| 6. Cross Reference
Frame Displacement & Model Code Crossover
| HENGYUHANG Model | Danfoss / Sauer-Danfoss Equivalent | Displacement (cm³/rev) | Mounting Flange | Standard Drive Shaft | Main Work Ports |
|---|---|---|---|---|---|
| HYHT90R055 / HYHT90L055 | T90R055 / T90L055 / 90R055 / 90L055 | 55.0 cc | SAE C 4-Bolt (∅127 mm) | 21T 16/32 DP (C6) / 14T 12/24 (S1) | 1.00 in Code 62 Split Flange |
| HYHT90R075 / HYHT90L075 | T90R075 / T90L075 / 90R075 / 90L075 | 75.0 cc | SAE C 4-Bolt (∅127 mm) | 23T 16/32 DP (C7) / 23T Mixer (DC) | 1.00 in Code 62 Split Flange |
| HYHT90R100 / HYHT90L100 | T90R100 / T90L100 / 90R100 / 90L100 | 100.0 cc | SAE C 4-Bolt (∅127 mm) | 23T 16/32 DP (C7) / 23T Mixer (DC) | 1.00 in Code 62 Split Flange |
Control Module Interchangeability
| HENGYUHANG Control Code | Danfoss Control Code | Control Type | Operational Description | Field Compatibility |
|---|---|---|---|---|
| MA | MA | Manual Displacement Control (MDC) | Proportional manual control lever with internal spring-centering | 100% 1:1 Direct Field Drop-in |
| MS | MS | MDC with Neutral Start Switch | Includes integrated electrical safety switch for engine start lockout | 100% 1:1 Direct Field Drop-in |
| LU / LW | LU / LW | MDC Heavy-Duty Sealed / Offset | Offset handle with heavy-duty wiper seal for abrasive mixer truck environments | 100% 1:1 Direct Field Drop-in |
| DD | DD | 3-Position Electric Control (FNR) | 24V DC solenoid-activated forward-neutral-reverse directional control | 100% 1:1 Direct Field Drop-in |
| A4 / A5 | A4 / A5 | High Current EDC (HCEDC) | Dual proportional coils (12V / 24V) with Deutsch DT04-2P connectors | 100% 1:1 Direct Field Drop-in |
| 7. Brand Replacement
HENGYUHANG HYHT90 Series pumps serve as direct form-fit-function replacements for leading global closed-circuit hydrostatic transmission pumps:
Danfoss / Sauer-Danfoss: T90 Series (T90R055, T90R075, T90R100) & Series 90 (90R055, 90R075, 90R100)
Rexroth (Bosch Rexroth): A4VTG Series (A4VTG071, A4VTG090) & A4VG Series (A4VG56, A4VG71, A4VG90) Closed Circuit Pumps
Eaton (Danfoss / Vickers): Heavy Duty Model 33, 39, 46, 54, 64 Mixer & Propel Hydrostatic Pumps
PMP Pro-Mec: PMH P55, PMH P72, PMH P90 Heavy Duty Axial Piston Pumps for Concrete Mixers
Bondioli & Pavesi: M4PV Series (M4PV50, M4PV65, M4PV90) Closed Loop Pumps
Linde Hydraulics: HPV-02 Series (HPV55, HPV75, HPV105) Hydrostatic Pumps
| 8. Applications
Transit Concrete Mixer Drum Drives (6–18 m³): Serves as the core hydrostatic drive pump paired with S90/T90 fixed displacement motors and TMG planetary drum reduction gearboxes (TMG 51.2, 61.2, 71.2) to deliver controlled concrete mixing, agitating during transit, and high-speed discharge.
Road Compactor & Tandem Vibratory Rollers: Powers closed-loop traction propel drive and vibratory exciter eccentric shafts on heavy single-drum soil compactors, asphalt paving machines, and tandem vibrating rollers.
Agricultural Combine Harvesters & Self-Propelled Forage Cutters: Acts as primary hydrostatic ground drive transmission pump on modern harvesters and self-propelled sprayers, providing infinitely variable speed adjustment and seamless directional reversal.
Skid Steer Loaders & Compact Track Loaders (SSL / CTL): Drives independent left/right dual-path hydrostatic drive systems, enabling agile spin-turns, counter-rotation, and responsive handling under heavy digging cycles.
Horizontal Directional Drilling (HDD) & Trenchless Rigs: Supplies continuous high-pressure closed-circuit hydraulic power to carriage thrust/pullback racks and rotational drill head spindle drive motors.
Heavy Industrial Winches & Dredging Equipment: Drives bidirectional closed-circuit anchor winches, mooring capstans, and mining conveyor drives requiring high starting torque and precise low-speed creep control.
| 9. Packaging & Shipping
| Packaging Specification | Standard Configuration | Export Protection Detail |
|---|---|---|
| Port & Interface Sealing | Heavy-duty threaded polyethylene blanking plugs | Working ports A & B, suction S, case drains L1, L2, and all gauge ports sealed against moisture and dirt ingress |
| Surface Rust Prevention | Industrial corrosion-inhibitor oil spray + primer | Exterior machined pilot surfaces, flange mounting faces, and drive shaft splines coated with heavy-duty anti-rust oil |
| Inner Protective Barrier | Sealed VCI (Vapor Corrosion Inhibitor) plastic liner | Vacuum-sealed moisture-proof plastic enclosure packed with active industrial desiccant sachets |
| Cushioning & Positioning | Custom-molded high-density EPE foam cradles | Precision-contoured internal foam cushions immobilizing the pump body, shaft extension, and control valve block |
| Outer Shipping Container | Heavy-duty heat-treated fumigation-free wooden case | Multi-ply plywood export crates compliant with ISPM 15 standards, reinforced with high-tensile steel banding |
| Consignment Traceability | Dual-label identification system | Weatherproof exterior shipping markings; etched stainless steel serial nameplate riveted to pump housing |
| 10. Why Choose Hengyuhang?
Direct Factory Precision Manufacturing & Sub-Micron CNC Craftsmanship: Quanzhou Hengyuhang Power Technology Co., Ltd. operates a high-precision manufacturing facility equipped with advanced multi-axis CNC turning-milling centers, horizontal boring centers, and automated spherical grinding units. Critical hydraulic rotating components—including ductile iron cylinder barrels, brass-clad bi-metallic valve plates, high-tensile alloy steel pistons, and nitrided swashplate shoes—are machined to ultra-tight geometric tolerances. We maintain cylinder-to-valve-plate contact flatness within 0.8 μm and surface finish smoothness of Ra < 0.2 μm. By sourcing directly from our factory floor, customers bypass intermediary trading markups, gain full batch-to-batch traceability, and secure rock-solid supply continuity at competitive factory pricing.
100% Digitalized Multi-Parameter Test Bench Quality Verification: Zero unverified pumps leave our factory. Every single HYHT90 pump is mounted on our automated digital hydraulic test benches to undergo rigorous pre-shipment performance screening. Our multi-stage dynamic testing protocol evaluates:
Full-range speed testing up to rated rpm across no-load, partial-load, and full continuous load cycles.
High-pressure endurance holding at continuous 350 to 420 bar [5,076 to 6,000 psi] and transient pressure spike verification at 420 to 480 bar [6,092 to 7,000 psi].
Volumetric efficiency certification (≥94%) and overall mechanical efficiency validation (≥92%).
Dual multifunction high-pressure relief valve popping accuracy and sequenced pressure limiter (PL) cut-off responsiveness.
Internal gerotor charge pump output flow and charge relief valve cracking pressure verification (20 to 24 bar).
Internal case drain leakage flow measurement under peak operating temperatures (60 °C to 85 °C) to eliminate seal failure risks. Every unit is assigned a permanent engraved serial number linked directly to an individual digital QA test dossier for complete customer peace of mind.
Guaranteed 1:1 OEM Drop-In Interchangeability with Zero Re-Engineering: Engineered strictly to original Danfoss / Sauer-Danfoss T90 Series geometric, hydraulic, and mechanical interface standards, HENGYUHANG pumps provide true plug-and-play field interchangeability. Every critical mounting parameter—including standard ISO 3019-1 / SAE pilot diameters (SAE C ∅127 mm), mounting bolt pitch circles, drive shaft splines (ANSI B92.1 Class 5 21T/23T and specialized mixer drive flanges), Code 62 split flange main ports, and SAE straight-thread O-ring boss ports—matches OEM dimensions down to the millimeter. Mixer truck fleet operators, equipment builders, and hydraulic rebuilders can replace failed units in under two hours with zero piping alterations, zero bracket modifications, and zero harness adaptations.
Agile Engineering Customization & Dedicated Application Co-Development: Backed by a team of senior fluid power design engineers with over 15 years of closed-circuit hydrostatic specialization, Hengyuhang provides flexible, tailored engineering services to accommodate unique machine operating requirements:
Customized drive shaft configurations (special spline tooth profiles, metric threads, or dedicated transit mixer PTO mounting flanges).
Bespoke mechanical displacement limiters to restrict maximum forward or reverse swashplate travel for specialized machine speeds.
Tailored charge pump displacements (14, 17, 20, and 26 cc options) to feed demanding auxiliary hydraulic cooling, chute-raising, or drum braking circuits.
Factory-calibrated high-pressure relief valves (260 to 420 bar) and pre-installed control orifices to fine-tune swashplate acceleration/deceleration response times.
Tailored control module conversions across MDC, MDC with NSS, FNR, and HCEDC (12V/24V Deutsch DT04-2P) with low-MOQ prototype support for OEM system development and legacy fleet retrofits.
Strategic Component Inventory, Rapid Dispatch & End-to-End Global Logistics: To minimize machine downtime and lost contractor revenue, Hengyuhang maintains an extensive buffer inventory of semi-finished ductile iron housings, finished rotating barrel groups, swashplate assemblies, charge pumps, and imported FKM/Viton seal kits across all 3 displacements (055, 075, 100). Standard configuration pumps ship within 48 to 72 hours of order confirmation. We partner with leading international freight forwarders (DHL, FedEx, UPS) and global maritime carriers to provide complete Door-to-Door (DDP) customs-cleared logistics, transparent tracking, and reliable door delivery across North America, Europe, Southeast Asia, Australia, and South America.
Comprehensive 12-Month Factory Warranty & Lifetime Engineering Support: We stand firmly behind the durability of our hydrostatic products. All HENGYUHANG HYHT90 Series axial piston variable displacement pumps carry an unconditional 12-month factory replacement warranty against manufacturing defects and material failures. In addition to hardware protection, customers enjoy lifetime engineering support from our technical department—including free 2D/3D CAD model verification, hydraulic circuit diagram reviews, commissioning guidance, fluid cleanliness troubleshooting, and guaranteed availability of factory-original maintenance rotating groups, valve plates, and seal repair kits.
HENGYUHANG Axial Piston Variable Displacement Pumps HYHT90 Series (HYHT90R / HYHT90L / HYHT90P) are compact, high-power-density hydraulic pumps engineered specifically for heavy-duty closed-circuit hydrostatic transmissions. Derived from proven Series 90 rotary group technology and optimized for extreme cyclic duty cycles—including transit concrete mixer drum drives (6 to 18 m³), vibratory soil compactors, and agricultural machinery—the HYHT90 Series utilizes a parallel 9-piston rotating group with guided slippers and an adjustable cradle swashplate. Reversing the swashplate angle seamlessly reverses oil flow direction across neutral, enabling smooth bi-directional drum charging and discharging rotation. Available in three core displacements—55 cm³, 75 cm³, and 100 cm³/rev—the series operates at continuous working pressures up to 350 bar (5076 psi) and maximum peak pressures up to 420 bar (6092 psi), with selected heavy-duty variants supporting up to 480 bar (7000 psi). Featuring integrated gerotor charge pumps (14 to 26 cm³/rev), internal high-pressure relief valves (HPRV), sequenced pressure limiters (PL), manual mechanical displacement control (MDC), high-current proportional electric control (HCEDC), and PLUS+1 digital compatibility, the HYHT90 Series is custom-engineered to benchmark the mounting interfaces, performance envelopes, and control functions of Danfoss / Sauer-Danfoss Series T90 (T90R / T90L / T90P) axial piston pumps.
Technical Benchmark & Engineering Notice: All technical parameters, displacement ratings, rotational speeds, and dimensional interface standards presented on this page reference original manufacturer published technical documentation (Danfoss Power Solutions Series T90 Technical Information Manual BC152886484177en-000307 / former BC00000063, Rev 0307 / June 2022, Pages 1–45; Sauer-Danfoss T90 Data Sheet 11064890 Rev A / April 2009, Pages 1–2; and Sauer-Danfoss Transit Mixer Brochure L1118131 Rev AA / September 2011, Pages 1–6). Replacement units are custom-manufactured; key mounting interfaces, centering pilots, shaft splines, port threads, and control pressure settings must be cross-verified against confirmed factory engineering drawings and test certificates prior to final commissioning.
Proven 9-Piston Cylinder Rotating Group: Optimized 9-piston rotating assembly with brass slippers, hardened spherical cylinder block, and heavy-duty cradle bearings delivers superior volumetric efficiency (≥95%) and extended operational life under continuous reversing and pulsating loads.
Targeted Three-Displacement Spectrum: Precision-engineered in three high-demand frame sizes—55 cm³ (3.35 in³), 75 cm³ (4.59 in³), and 100 cm³ (6.10 in³/rev)—specifically covering standard 6 m³, 8 m³, 9 m³, 10 m³, and 12 m³ transit concrete mixer drum volumes.
High Pressure & Low-Speed High-Torque Performance: Continuous working pressure rated at 350 bar (5076 psi) with maximum peak pressure up to 420 bar (6092 psi), maintaining high hydrostatic system pressure even at low engine idle speeds (400 to 500 rpm) during on-site concrete pouring operations.
Compact Envelope for Confined Chassis Packaging: Substantially reduced overall length (306.1 mm on size 075; 338.3 mm on size 100) and lightweight casing (40 to 68 kg) provide superior power density and flexible installation freedom within crowded truck chassis engine bays.
High-Capacity Integrated Charge Pump: Built-in gerotor charge pump (14, 17, 20, or 26 cm³/rev) ensures rapid servo system response, positive low-pressure loop anti-cavitation replenishment, and continuous fluid circulation across heat exchangers.
Transit Mixer Specific Porting & Valving (Option 8A): Working ports A and B feature 1.00 in SAE J518 Code 62 split flanges with M12×1.75 metric mounting threads (24 mm full thread depth), integrated high-pressure relief valves (HPRV), and manual loop bypass hex for vehicle towing.
Versatile Control Options: Standard Manual Displacement Control (MDC) with spring-centered return, optional neutral start safety switch (NSS), offset handle, or High-Current Electric Proportional Control (HCEDC, 12V/24V IP69K DEUTSCH DT04-2P connectors) for modern electronic automated drum control.
Auxiliary Rear Through-Drive Capability: Optional rear auxiliary mounting pads (SAE-A 9T, SAE-B 13T, SAE-C 14T) enable direct tandem coupling of secondary hydraulic pumps for water pumps, chute positioning, or auxiliary steering.
While primarily recognized as the benchmark hydrostatic pump for mobile transit concrete mixer trucks, the HENGYUHANG HYHT90 Series is equally optimized for heavy-duty closed-loop mobile machinery:
Concrete Transit Mixer Trucks (6 to 18 m³): Closed-loop drum rotation drive paired with fixed displacement motors (HYH90M055 / HYH90M075 / HYH90M100) and planetary drum reducers (TMG 51.2 / 61.2 / 71.2) for continuous mixing and discharging.
Vibratory Soil Compactors & Road Rollers: Heavy-duty closed-circuit propel and vibratory exciter drives on single-drum and tandem asphalt compaction rollers requiring reliable reversing control.
Agricultural Combines & Self-Propelled Harvesters: Primary ground travel traction and auxiliary header drives on agricultural machinery operating across high-load harvesting terrain.
Specialized Municipal & Utility Vehicles: Hydrostatic drive transmissions on large mechanical street sweepers, snow blowers, and heavy industrial winch systems.
Transit Concrete Mixer Truck Drivetrain Configuration Matrix (Reference Guide):
| Mixer Drum Capacity | HYHT90 Variable Pump | Matched Hydraulic Motor | Matched Drum Reducer | Reducer Ratio (i) | Max Output Torque | Pump Speed @ 16 rpm Drum |
|---|---|---|---|---|---|---|
| 6 – 7 m³ Drum | HYHT90P055 (55 cm³/rev) | HYH90M055 (55 cm³/rev) | TMG 51.2 Planetary | 101.9 : 1 | 51,000 N·m | 2000 rpm (Idle 400 rpm) |
| 8 – 9 m³ Drum | HYHT90P075 (75 cm³/rev) | HYH90M075 (75 cm³/rev) | TMG 61.2 Planetary | 111.5 : 1 | 61,000 N·m | 2000 rpm (Idle 400 rpm) |
| 10 m³ Drum | HYHT90P100 (100 cm³/rev) | HYH90M100 (100 cm³/rev) | TMG 61.2 Planetary | 111.5 : 1 | 61,000 N·m | 2000 rpm (Idle 400 rpm) |
| 12 – 14 m³ Drum | HYHT90P100 (100 cm³/rev) | HYH90M100 (100 cm³/rev) | TMG 71.2 Planetary | 131.3 : 1 | 71,000 N·m | 2300 rpm (Idle 400 rpm) |
| Technical Parameter / Frame Size | HYHT90-055 | HYHT90-075 | HYHT90-100 |
|---|---|---|---|
| Maximum Displacement [cm³/rev] | 55.0 | 75.0 | 100.0 |
| Maximum Displacement [in³/rev] | 3.35 | 4.59 | 6.10 |
| Minimum Operating Input Speed [rpm] | 500 (Idle 400–450) | 500 (Idle 400–450) | 500 (Idle 400–450) |
| Rated Input Speed at Max Disp [rpm] | 3500 | 3150 (3600 max continuous) | 3000 (3300 max continuous) |
| Maximum Intermittent Input Speed [rpm] | 3700 | 3350 (3950 peak intermittent) | 3200 (3650 peak intermittent) |
| Maximum Continuous Working Pressure [bar / psi] | 350 / 5076 (420 / 6000 rated) | 350 / 5076 (420 / 6000 rated) | 350 / 5076 (420 / 6000 rated) |
| Maximum Peak System Pressure [bar / psi] | 420 / 6092 (480 / 7000 peak) | 420 / 6092 (480 / 7000 peak) | 420 / 6092 (480 / 7000 peak) |
| Theoretical Flow at Rated Speed [L/min / US gpm] | 193 / 51 | 270 / 71 | 300 / 79 (330 / 87 @ 3300 rpm) |
| Theoretical Input Torque at Vg max [N·m/bar] | 0.88 | 1.19 | 1.59 |
| Theoretical Input Torque at Vg max [lbf·in/1000 psi] | 530 | 730 | 970 |
| Corner Power at Rated Speed & 350 bar [kW / HP] | 112 / 150 | 158 / 211 | 175 / 235 (193 / 258 @ 3300 rpm) |
| Rotating Group Moment of Inertia J [kg·m²] | 0.0065 | 0.0100 | 0.0171 |
| Dry Weight (with Manual Control MDC MA) [kg / lbs] | 40 / 88 | 49 / 108 | 68 / 150 |
| Standard Charge Pump Displacement [cm³/rev] | 14 (Code C, 0.85 in³) | 17 (Code D, 1.04 in³) | 20 (Code E, 1.22 in³) / 26 (Code F) |
* All technical parameters referenced from Danfoss Series T90 Technical Information Manual BC152886484177en-000307 (Pages 8–9) and Data Sheet 11064890. Flow and torque values are theoretical without efficiency losses. Operational parameters for custom replacement units are verified through confirmed engineering approval drawings and factory dynamometer test certificates prior to dispatch.
Part 1: Primary mounting flange standards (ISO 3019-1 / SAE J744), centering pilot diameters, bolt patterns, ANSI B92.1 drive shafts, and rear auxiliary through-drive pads.
| Frame Size | Primary Mounting Flange | Centering Pilot Ø (ISO 3019-1) | Bolt Hole Pitch & Pattern | Standard Splined Drive Shaft | Auxiliary Rear Through-Drive Pads |
|---|---|---|---|---|---|
| HYHT90-055 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] (+0 / -0.05 mm) | 114.5 mm [4.51 in] square / 4x Ø14.3 mm | 21T 16/32 DP (C6) / 21T with M10 & Flange (DD) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
| HYHT90-075 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] (+0 / -0.05 mm) | 114.5 mm [4.51 in] square / 4x Ø14.34 mm | 23T 16/32 DP (C7 / D7) / 23T with Flange (DC) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
| HYHT90-100 | SAE-C 4-bolt (Flange 127-4) | Ø127.0 mm [5.000 in] (+0 / -0.05 mm) | 114.5 mm [4.51 in] square / 4x Ø14.27 mm | 23T 16/32 DP (C7 / D7) / 23T with Flange (DC) | SAE-A (9T) / SAE-B (13T) / SAE-C (14T) |
Part 2: Main working ports A & B (SAE J518 Code 62 4-bolt split flange with M12 metric threads for mixer trucks), case drain outlets, charge suction inlet, and gauge ports.
| Frame Size | Main Working Ports A & B (ISO 6162-2) | Port Layout Executions | Case Drain Ports L1, L2 (ISO 11926-1) | Charge Pump Suction Port S | Gauge Ports M1, M2, M3, M4, M5 |
|---|---|---|---|---|---|
| HYHT90-055 | 1.00 in (DN25) Code 62 (M12×1.75, 24 mm thd) | Same side (Option 8A/80) or Opposite (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/16-12 UN-2B (SAE-16 O-Ring Boss) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYHT90-075 | 1.00 in (DN25) Code 62 (M12×1.75, 24 mm thd) | Same side (Option 8A/80) or Opposite (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/16-12 UN-2B (SAE-16 O-Ring Boss) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| HYHT90-100 | 1.00 in (DN25) Code 62 (M12×1.75, 24 mm thd) | Same side (Option 8A/80) or Opposite (60) | 1 1/16-12 UN-2B (SAE-12 O-Ring Boss) | 1 5/8-12 UN-2B (SAE-20 O-Ring Boss) | 9/16-18 UNF-2B (SAE-6 O-Ring Boss) |
| Control Code | Designation & Actuation | Operational Principles & System Integration |
|---|---|---|
| MDC (MA / MS / LU / LW) | Manual Displacement Control (Mechanical Handle Actuation) | Direct mechanical handle rotation control specifically designed for transit mixer drum operation. Handle movement modulates internal pilot spool, directing servo pressure to tilt the cradle swashplate proportionally. Option MS integrates neutral start safety switch (NSS); Option LU features offset handle with environmental dust seal; Option LW provides ruggedized construction for harsh concrete job sites. |
| HCEDC (A4 / A5) | High Current Electric Displacement Control (Proportional Dual Solenoids) | High-current electro-hydraulic proportional control with IP67/IP69K rated DEUTSCH DT04-2P connectors. Proportional solenoids meter pilot pressure to double-acting servo piston with internal mechanical swashplate feedback. Operating current: 12V DC (A4: 710 to 1640 mA, coil resistance 3.66 Ω); 24V DC (A5: 352 to 820 mA, coil resistance 14.2 Ω). PWM signal frequency 70 to 200 Hz (100 Hz recommended). |
| FNR (DD) | 3-Position Electric Solenoid Control (Forward-Neutral-Reverse) | Bi-stable on/off solenoid control utilizing 24 VDC solenoids (DD, 170 mA with DIN 43650 connector) to shift pump swashplate to full forward displacement, spring-centered neutral, or full reverse displacement. Ideal for remote cab switch control on specialized compaction rollers. |
| LY / L1 | 2-Position Solenoid with Brake Valve (24 VDC Solenoid + MDC Handle) | Combined manual displacement control handle with an integrated 24 VDC 2/2-way solenoid valve and parking brake pressure release port. Provides fail-safe vehicle brake release interlock with dust seal protection. L1 includes offset control handle. |
| Pos. | Code Segment | Available Options | Description & Engineering Specifications |
|---|---|---|---|
| 01 | Product Architecture | HYHT90 | Series T90 heavy-duty closed-circuit axial piston variable displacement pump technology |
| 02 | Rotation Direction | R L | Clockwise rotation (CW, viewed from shaft end) Counterclockwise rotation (CCW, viewed from shaft end) |
| 03 | Frame Displacement | 055 075 100 | Displacement: 55.0 cm³ [3.35 in³/rev] Displacement: 75.0 cm³ [4.59 in³/rev] Displacement: 100.0 cm³ [6.10 in³/rev] |
| 04 | Control Execution | MA / MS LU / LW LY / L1 DD A4 / A5 | Manual Displacement Control (MA: standard; MS: with Neutral Start Switch) MDC with offset handle & dust seal (LU) or rugged open environment design (LW) 2-position 24V solenoid valve with brake port (LY: standard; L1: offset handle) 3-position electric FNR control (24 VDC, DIN 43650 connector) HCEDC High Current Electric Control (A4: 12V; A5: 24V, DEUTSCH DT04-2P) |
| 05 | Pressure Regulation | D 1 | High-pressure relief valves only (HPRV), standard execution for transit mixer trucks Multi-function valves with sequenced Pressure Limiter (PL, 140 to 450 bar) and HPRV |
| 06 | Auxiliary Mounting Pad | NN AB BC CD | No auxiliary mounting pad (sealed rear cover, standard mixer execution) SAE-A auxiliary mounting pad with sealed cover (9T 16/32 DP internal spline sleeve) SAE-B auxiliary mounting pad with sealed cover (13T 16/32 DP internal spline sleeve) SAE-C auxiliary mounting pad with sealed cover (14T 12/24 DP internal spline sleeve) |
| 07 | End Cap Ports Layout | 8A 80 60 | Radial twin ports on same side with M12×1.75 metric threads (for Mixer Truck) Radial twin ports on same side with standard UNC threads (SAE J518 Code 62) Radial ports on opposite sides (SAE J518 Code 62 split flange boss) |
| 08 | Filtration Execution | S / F P R | Suction filtration system for internal charge pump (Code S or F, standard) Integrated pressure filtration with short spin-on filter canister Remote pressure filtration circuit without filter canister |
| 09 | Displacement Limiters | 3 4 | Without mechanical stroke limiters (standard) With mechanical displacement limiters on both sides (factory preset to 100% max displacement) |
| 10 | Drive Shaft Configuration | C6 / C7 D7 / D9 DC / DD S1 | 21T 16/32 DP (C6 on 055/075) or 23T 16/32 DP (C7 on 075/100) ANSI splines 23T (D7) or 21T (D9) 16/32 DP splines with M10 front threaded hole 23T (DC) or 21T (DD) with M10 front thread and mounting flange (for Mixer Truck) 14T 12/24 DP splined shaft |
| 11 | Charge Pump Size | C D E F | 14 cm³/rev [0.85 in³/rev] internal gerotor charge pump (standard on 055) 17 cm³/rev [1.04 in³/rev] internal gerotor charge pump (standard on 075) 20 cm³/rev [1.22 in³/rev] internal gerotor charge pump (standard on 100) 26 cm³/rev [1.58 in³/rev] high-capacity charge pump (optional on 100) |
| 12 | Control Orifice Setting | 00 / 03 / C5 G8 / GB F4 / F5 / F6 | MDC orifices: None (00), Ø0.81 mm inlet (03, standard), or Ø0.81 mm with Ø1.40 mm drains (C5) FNR orifices: Ø0.66 mm (G8) or Ø0.81 mm (GB) with Ø1.20 mm drains HCEDC orifices: Ø0.81 mm (F4), Ø1.57 mm (F5), or Ø2.34 mm (F6) with Ø2.50 mm servos |
| 13 | Special Hardware Feature | MIX / MIL MKX / MJX FBK / FBL | CP 15 +0.5° valve plate (MIX for mixer truck; MIL for mixer truck with HCEDC) CP 15 +0.5° valve plate with nested t-bar springs (MKX) or not for transit mixer (MJX) CP 15 +0.5° valve plate for HCEDC (FBK with nested t-bar springs; FBL standard) |
| 14 | High Pressure Relief (Y/Z) | 26 / 29 32 / 35 | HPRV pressure setting for Port A (Y) and Port B (Z): 260 bar [26] or 290 bar [29] HPRV pressure setting: 320 bar [32] or 350 bar [35, factory standard for mixers] |
| 15 | Charge Pressure Relief (K) | 20 24 | Charge relief pressure setting: 20 bar [20 = 290 psi] Charge relief pressure setting: 24 bar [24 = 350 psi, factory standard setting] |
Example Standard Order Codes: HYHT90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 (75 cm³, CW, Manual MDC Control, Mixer HPRV, No Auxiliary Pad, Metric 8A Ports, Suction Filtration, 23T DC Spline with Flange, 17 cm³ Charge Pump, Ø0.81 mm Orifice, Transit Mixer Valve Plate, 350 bar HPRV, 24 bar Charge Relief) or HYHT90L100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 (100 cm³, CCW, 12V HCEDC Proportional Control, Pressure Limiter, SAE-B Auxiliary Pad, Integral Pressure Filter, 23T Spline, 20 cm³ Charge Pump, 350 bar Relief, 24 bar Charge Relief).
HENGYUHANG HYHT90 Series variable displacement pumps are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss T90 Series mounting dimensions, drive shaft splines, port layouts, and transit mixer control configurations. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:
| OEM Danfoss Model Code | HENGYUHANG Benchmarked Model | Displacement & Flange | Input Shaft & Ports | Control & Valve Setting | Compatibility Status |
|---|---|---|---|---|---|
| T90R055-MA-D-NN-8A-S-3-DD-C-03-MIX-35-35-24 | HYHT90R055-MA-D-NN-8A-S-3-DD-C-03-MIX-35-35-24 | 55 cm³, SAE-C 4-bolt | 21T DD Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | HYHT90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90L075-MS-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | HYHT90L075-MS-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | MDC with NSS, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R100-MA-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | HYHT90R100-MA-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90L100-MS-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | HYHT90L100-MS-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | MDC with NSS, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R075-A4-1-NN-80-S-3-C7-D-F4-FBL-35-35-24 | HYHT90R075-A4-1-NN-80-S-3-C7-D-F4-FBL-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T C7 Spline, Twin 80 Ports | 12V HCEDC Control, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 | HYHT90R100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T C7 Spline, SAE-B Rear Pad | 12V HCEDC + Spin-on Filter | Benchmarked Equivalent (Verify Fit) |
1. Initial Casing Pre-filling & Air Bleeding: Prior to initial startup, the pump casing must be filled with clean, filtered hydraulic oil through the highest positioned case drain port (L1 or L2) and thoroughly deaerated. Dry startup will cause immediate boundary friction damage and galling to the brass piston slippers, cylinder barrel face, and swashplate cradle bearings.
2. Charge Pump Inlet Suction & Vacuum Restrictions: Suction line S must be sized to ensure absolute charge pump suction pressure remains ≥ 0.7 bar abs [9 in Hg vacuum] during normal operating temperature. Minimum allowable suction pressure during cold start is 0.2 bar abs [24 in Hg vacuum]. Clogged suction filters cause severe charge pump cavitation and rapid failure.
3. Housing Drain Line Routing & Pressure Limits: Case drain lines must be piped directly back to the hydraulic reservoir below the minimum oil level without check valves or restrictive fittings. Continuous casing pressure must not exceed 3.0 bar [40 psi] (cold start transient maximum ≤ 5.0 bar [75 psi]). External shaft seal differential pressure must remain ≤ 0.4 bar [5.8 psi].
4. Fluid Cleanliness Standard: Maintain fluid cleanliness strictly according to ISO 4406 at 22/18/13 or cleaner. For charge pressure filtration, utilize filter elements with β15-20 = 75 (β10 ≥ 10). Transit mixer wash-down water and cement dust ingress must be strictly prevented from contaminating hydraulic tank breathers and reservoir fill caps.
5. Fluid Viscosity & Operating Temperature Range: Recommended operating viscosity is νopt = 12 to 80 mm²/s [66 to 370 SUS] (minimum allowable 7 mm²/s [49 SUS]; cold-start maximum 1600 mm²/s [7500 SUS]). Continuous oil temperature should remain within 60 to 85 °C [140 to 185 °F] (rated maximum 104 °C [220 °F]; intermittent peak ≤ 115 °C [240 °F]).
Reference Benchmark Datasheets: Danfoss Power Solutions Series T90 Axial Piston Pumps Technical Information Manual (Document Ref: BC152886484177en-000307 / former BC00000063, Rev 0307, June 2022 Edition, Pages 1–45); Sauer-Danfoss T90 Data Sheet (Document Ref: 11064890, Rev A, April 2009 Edition, Pages 1–2); and Sauer-Danfoss Transit Mixer Drivetrain Brochure (Document Ref: L1118131, Rev AA, September 2011 Edition, Pages 1–6).
Quality Inspection & Factory Dyno Testing: Every HENGYUHANG HYHT90 variable pump is dynamically validated on automated hydraulic test benches for full-displacement volumetric flow, input torque, servo control hysteresis, low-idle pressure generation, and high-pressure relief valve cracking accuracy under 350 bar continuous and 420 bar peak pressure prior to dispatch.
Custom Engineering & Tailored Configurations: HENGYUHANG provides custom transit mixer input drive shafts (with metric M10 end threads and front flange couplings), specialized manual control handle geometries, tailored charge pump displacements, customized relief valve pressure settings, and PLUS+1 compatible solenoid resistance ratings. Critical mounting dimensions, pilot tolerances, and hydraulic circuit parameters should be cross-verified against OEM reference drawings for specific machine serial numbers.
| Technical Parameter / Frame Size | HYHT90-055 | HYHT90-075 | HYHT90-100 |
|---|---|---|---|
| Maximum Displacement [cm³/rev] | 55.0 | 75.0 | 100.0 |
| Maximum Displacement [in³/rev] | 3.35 | 4.59 | 6.10 |
| Minimum Operating Input Speed [rpm] | 500 (Idle 400–450) | 500 (Idle 400–450) | 500 (Idle 400–450) |
| Rated Input Speed at Max Disp [rpm] | 3500 | 3150 (3600 max continuous) | 3000 (3300 max continuous) |
| Maximum Intermittent Input Speed [rpm] | 3700 | 3350 (3950 peak intermittent) | 3200 (3650 peak intermittent) |
| Maximum Continuous Working Pressure [bar / psi] | 350 / 5076 (420 / 6000 rated) | 350 / 5076 (420 / 6000 rated) | 350 / 5076 (420 / 6000 rated) |
| Maximum Peak System Pressure [bar / psi] | 420 / 6092 (480 / 7000 peak) | 420 / 6092 (480 / 7000 peak) | 420 / 6092 (480 / 7000 peak) |
| Theoretical Flow at Rated Speed [L/min / US gpm] | 193 / 51 | 270 / 71 | 300 / 79 (330 / 87 @ 3300 rpm) |
| Theoretical Input Torque at Vg max [N·m/bar] | 0.88 | 1.19 | 1.59 |
| Theoretical Input Torque at Vg max [lbf·in/1000 psi] | 530 | 730 | 970 |
| Corner Power at Rated Speed & 350 bar [kW / HP] | 112 / 150 | 158 / 211 | 175 / 235 (193 / 258 @ 3300 rpm) |
| Rotating Group Moment of Inertia J [kg·m²] | 0.0065 | 0.0100 | 0.0171 |
| Dry Weight (with Manual Control MDC MA) [kg / lbs] | 40 / 88 | 49 / 108 | 68 / 150 |
| Standard Charge Pump Displacement [cm³/rev] | 14 (Code C, 0.85 in³) | 17 (Code D, 1.04 in³) | 20 (Code E, 1.22 in³) / 26 (Code F) |
* All technical parameters referenced from Danfoss Series T90 Technical Information Manual BC152886484177en-000307 (Pages 8–9) and Data Sheet 11064890. Flow and torque values are theoretical without efficiency losses. Operational parameters for custom replacement units are verified through confirmed engineering approval drawings and factory dynamometer test certificates prior to dispatch.
| Pos. | Code Segment | Available Options | Description & Engineering Specifications |
|---|---|---|---|
| 01 | Product Architecture | HYHT90 | Series T90 heavy-duty closed-circuit axial piston variable displacement pump technology |
| 02 | Rotation Direction | R L | Clockwise rotation (CW, viewed from shaft end) Counterclockwise rotation (CCW, viewed from shaft end) |
| 03 | Frame Displacement | 055 075 100 | Displacement: 55.0 cm³ [3.35 in³/rev] Displacement: 75.0 cm³ [4.59 in³/rev] Displacement: 100.0 cm³ [6.10 in³/rev] |
| 04 | Control Execution | MA / MS LU / LW LY / L1 DD A4 / A5 | Manual Displacement Control (MA: standard; MS: with Neutral Start Switch) MDC with offset handle & dust seal (LU) or rugged open environment design (LW) 2-position 24V solenoid valve with brake port (LY: standard; L1: offset handle) 3-position electric FNR control (24 VDC, DIN 43650 connector) HCEDC High Current Electric Control (A4: 12V; A5: 24V, DEUTSCH DT04-2P) |
| 05 | Pressure Regulation | D 1 | High-pressure relief valves only (HPRV), standard execution for transit mixer trucks Multi-function valves with sequenced Pressure Limiter (PL, 140 to 450 bar) and HPRV |
| 06 | Auxiliary Mounting Pad | NN AB BC CD | No auxiliary mounting pad (sealed rear cover, standard mixer execution) SAE-A auxiliary mounting pad with sealed cover (9T 16/32 DP internal spline sleeve) SAE-B auxiliary mounting pad with sealed cover (13T 16/32 DP internal spline sleeve) SAE-C auxiliary mounting pad with sealed cover (14T 12/24 DP internal spline sleeve) |
| 07 | End Cap Ports Layout | 8A 80 60 | Radial twin ports on same side with M12×1.75 metric threads (for Mixer Truck) Radial twin ports on same side with standard UNC threads (SAE J518 Code 62) Radial ports on opposite sides (SAE J518 Code 62 split flange boss) |
| 08 | Filtration Execution | S / F P R | Suction filtration system for internal charge pump (Code S or F, standard) Integrated pressure filtration with short spin-on filter canister Remote pressure filtration circuit without filter canister |
| 09 | Displacement Limiters | 3 4 | Without mechanical stroke limiters (standard) With mechanical displacement limiters on both sides (factory preset to 100% max displacement) |
| 10 | Drive Shaft Configuration | C6 / C7 D7 / D9 DC / DD S1 | 21T 16/32 DP (C6 on 055/075) or 23T 16/32 DP (C7 on 075/100) ANSI splines 23T (D7) or 21T (D9) 16/32 DP splines with M10 front threaded hole 23T (DC) or 21T (DD) with M10 front thread and mounting flange (for Mixer Truck) 14T 12/24 DP splined shaft |
| 11 | Charge Pump Size | C D E F | 14 cm³/rev [0.85 in³/rev] internal gerotor charge pump (standard on 055) 17 cm³/rev [1.04 in³/rev] internal gerotor charge pump (standard on 075) 20 cm³/rev [1.22 in³/rev] internal gerotor charge pump (standard on 100) 26 cm³/rev [1.58 in³/rev] high-capacity charge pump (optional on 100) |
| 12 | Control Orifice Setting | 00 / 03 / C5 G8 / GB F4 / F5 / F6 | MDC orifices: None (00), Ø0.81 mm inlet (03, standard), or Ø0.81 mm with Ø1.40 mm drains (C5) FNR orifices: Ø0.66 mm (G8) or Ø0.81 mm (GB) with Ø1.20 mm drains HCEDC orifices: Ø0.81 mm (F4), Ø1.57 mm (F5), or Ø2.34 mm (F6) with Ø2.50 mm servos |
| 13 | Special Hardware Feature | MIX / MIL MKX / MJX FBK / FBL | CP 15 +0.5° valve plate (MIX for mixer truck; MIL for mixer truck with HCEDC) CP 15 +0.5° valve plate with nested t-bar springs (MKX) or not for transit mixer (MJX) CP 15 +0.5° valve plate for HCEDC (FBK with nested t-bar springs; FBL standard) |
| 14 | High Pressure Relief (Y/Z) | 26 / 29 32 / 35 | HPRV pressure setting for Port A (Y) and Port B (Z): 260 bar [26] or 290 bar [29] HPRV pressure setting: 320 bar [32] or 350 bar [35, factory standard for mixers] |
| 15 | Charge Pressure Relief (K) | 20 24 | Charge relief pressure setting: 20 bar [20 = 290 psi] Charge relief pressure setting: 24 bar [24 = 350 psi, factory standard setting] |
Example Standard Order Codes: HYHT90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 (75 cm³, CW, Manual MDC Control, Mixer HPRV, No Auxiliary Pad, Metric 8A Ports, Suction Filtration, 23T DC Spline with Flange, 17 cm³ Charge Pump, Ø0.81 mm Orifice, Transit Mixer Valve Plate, 350 bar HPRV, 24 bar Charge Relief) or HYHT90L100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 (100 cm³, CCW, 12V HCEDC Proportional Control, Pressure Limiter, SAE-B Auxiliary Pad, Integral Pressure Filter, 23T Spline, 20 cm³ Charge Pump, 350 bar Relief, 24 bar Charge Relief).
HENGYUHANG HYHT90 Series variable displacement pumps are custom-engineered to benchmark OEM Danfoss / Sauer-Danfoss T90 Series mounting dimensions, drive shaft splines, port layouts, and transit mixer control configurations. Exact mechanical fitment should be cross-verified against OEM reference drawings for specific machine serial numbers:
| OEM Danfoss Model Code | HENGYUHANG Benchmarked Model | Displacement & Flange | Input Shaft & Ports | Control & Valve Setting | Compatibility Status |
|---|---|---|---|---|---|
| T90R055-MA-D-NN-8A-S-3-DD-C-03-MIX-35-35-24 | HYHT90R055-MA-D-NN-8A-S-3-DD-C-03-MIX-35-35-24 | 55 cm³, SAE-C 4-bolt | 21T DD Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | HYHT90R075-MA-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90L075-MS-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | HYHT90L075-MS-D-NN-8A-S-3-DC-D-03-MIX-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | MDC with NSS, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R100-MA-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | HYHT90R100-MA-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | Manual MDC, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90L100-MS-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | HYHT90L100-MS-D-NN-8A-S-3-DC-E-03-MIX-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T DC Spline, Metric 8A Ports | MDC with NSS, HPRV 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R075-A4-1-NN-80-S-3-C7-D-F4-FBL-35-35-24 | HYHT90R075-A4-1-NN-80-S-3-C7-D-F4-FBL-35-35-24 | 75 cm³, SAE-C 4-bolt | 23T C7 Spline, Twin 80 Ports | 12V HCEDC Control, PL 350 bar | Benchmarked Equivalent (Verify Fit) |
| T90R100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 | HYHT90R100-A4-1-BC-80-P-3-C7-E-F4-FBL-35-35-24 | 100 cm³, SAE-C 4-bolt | 23T C7 Spline, SAE-B Rear Pad | 12V HCEDC + Spin-on Filter | Benchmarked Equivalent (Verify Fit) |
No. 173, Xiacuo, Sihuang Village, Xiamei Town, Nan 'an City, Fujian Province